Preferred Language
Articles
/
x4a-t4YBIXToZYALmLMn
Girder Load Share for the Curved I-Girder Bridge Subjected to the Point Load
...Show More Authors

The objective of this research is to study experimentally and theoretically the girder vertical load share of the curved I-Girder bridges subjected to the point load in addition to the self-weigh and supper imposed dead loads. The experimental program consist of manufacturing and testing the five simply supported bridge models was scaled down by (1/10) from a prototype of 30m central span. The models carriageway central radii are 30 m, 15m or 10m. The girder spacing of the first two models is 175 mm with an overall carriageway width of 650mm. The girder spacing of the other three bridge models is 200mm with the overall carriageway width of 700 mm. The overall depth of the composite section was 164 mm. To investigate the effect of live load position on the girder vertical load share a point load was applied at different load levels and was varied across bridge width. Experimental results show that the main factor effect on the girder load share were the point load position, load level and the bridge curvature value, while the girder spacing had a less effect than that. The ANSYS Worckbench 14.5 commercial software was adopted to build up the Finite Element model. Results have shown that the numerical model was slightly stiffer than the experimental test bridge model. A good agreement was obtained between the experimental and analytical results for all models, the maximum deviation in results reach to13% in such a single case, while the convergence results are the prevailing situation.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri May 01 2015
Journal Name
Journal Of Engineering
Cooling Load Calculations For Typical Iraqi Roof And Wall Constructions Using Ashrae's RTS Method
...Show More Authors

The present work is an attempt to develop design data for an Iraqi roof and wall constructions using the latest ASHRAE Radiant Time Series (RTS) cooling load calculation method. The work involves calculation of cooling load theoretically by introducing the design data for Iraq, and verifies the results experimentally by field measurements. Technical specifications of Iraqi construction materials are used to derive the conduction time factors that needed in RTS method calculations. Special software published by Oklahoma state university is used to extract the conduction factors according to the technical specifications of Iraqi construction materials.  Good agreement between the average theoretical and measured cooli

... Show More
View Publication Preview PDF
Publication Date
Sat May 31 2025
Journal Name
Modern Sport
Comparison of the speed of hospitalization according to the training load of some physiological and biochemical variables of badminton players and runner800 m youth
...Show More Authors

It is necessary to use the means of recovery and other means that help to get rid of the effects of fatigue, as the game of badminton and the effectiveness of running 800 meters fall within the mixed system with the superiority of the anaerobic system by more than the air system, so requires the development of energy systems In proportion to the time of the match for badminton players and their travels and high performance and ability to tolerate the high level of lactic acid in the muscles and blood and increase the pain associated with the fatigue that occurs during the performance. In light of the physical and physiological processes of these actions N it should seek through training programs to develop your endurance and wind energy sys

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 01 2018
Journal Name
Al-khwarizmi Engineering Journal
Investigation of Load and Pressure Distribution on Wing with Wake Rollup for Low Speed Aircraft
...Show More Authors

The presented work shows a preliminary analytic method for estimation of load and pressure distributions on low speed wings with flow separation and wake rollup phenomena’s. A higher order vortex panel method is coupled with the numerical lifting line theory by means of iterative procedure including models of separation and wake rollup. The computer programs are written in FORTRAN which are stable and efficient.

      The capability of the present method is investigated through a number of test cases with different types of wing sections (NACA 0012 and GA(W)-1) for different aspect ratios and angles of attack, the results include the lift and drag curves, lift and pressure distributions along the wing s

... Show More
View Publication Preview PDF
Publication Date
Mon Jul 01 2024
Journal Name
Medical Journal Of Babylon
Viral Load of HBV and HCV Correlation to Torque Teno Virus (TTV) Co-Infection in Iraqi Patients
...Show More Authors
Abstract<sec> <title>Background:

While hepatitis viruses A–E are established, emerging evidence points to additional, novel viral hepatitis agents. The torqueteno virus (TTV) has garnered interest due to its prevalence among patients with hepatitis, suggesting potential hepatotropism.

Aim:

This study was conducted to detect TTV antigens in individuals infected with chronic hepatitis B (HBV) and/or C (HCV) using molecular diagnostics and to explore any associations between TTV presence and demographic characteristics of the cohort.

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sun May 15 2022
Journal Name
Bionatura
Survey the Microbial Load in the Tigris River in South of Baghdad City and Some of the Physiochemical Parameters
...Show More Authors

This study included an analysis of three stations (Al Dora, Al Za'franiya, and Arab Ejbur) chosen to study the Physiochemical and microorganism (Fungi and Bacteria) loud of the Tigris River in the southern section of Baghdad city. The result of this research shows that the highest temperature recorded in summer in Al Za'franiya was 37Co, while the lowest temperature recorded in winter in Al Dora was 9Co. and the value of pH recorded the highest in summer it was 7.9 in Arab Ejbur, and the lowest value was in winter 7.1 in Al Dora regions, While Total Organic Carbon (TOC) shows the highest values found in the summer was 6.7 Mg L-1in Al Za'franiya Samples, and the lowest values were 2.0 Mg L-1in Arab Ejbur during the winter. The more f

... Show More
View Publication
Scopus Crossref
Publication Date
Tue Dec 01 2009
Journal Name
2009 7th International Conference On Information, Communications And Signal Processing (icics)
The effect of traffic load on using XCAST based routing protocol in wireless ad hoc networks
...Show More Authors

View Publication
Scopus (1)
Crossref (2)
Scopus Crossref
Publication Date
Wed Mar 01 2023
Journal Name
Journal Of Engineering
Experimental Study on the Behavior of Square-Skirted Foundation Rested on Gypseous soil Under Inclined Load
...Show More Authors

This work investigates experimentally the effect of using a skirt with a square foundation of 100 mm width resting on dry gypseous soil (i.e., loose soil with 33% relative density), and subjected to an inclined load. Previous works did not study the use square skirted foundation rested on gypseous soil and subjected to inclined load. The investigated soil was brought from Tikrit city with 59% gypsum content. Standard physical and chemical tests on selected soil were carried out. Model laboratory tests were carried out to determine the effect of using a skirt with a square foundation on the load-settlement behavior of gypseous soil and subjected to inclined load with various Skirt depth (Ds) to foundation width (B) ratio

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat Feb 27 2021
Journal Name
Journal Of Engineering
Effect of Web Stiffeners on The Flexural Behavior of Composite GFRP- Concrete ‎Beam Under Impact Load
...Show More Authors

In this paper, numerical and experimental studies on the elastic behavior of glass fiber reinforced ‎polymer (GFRP) with stiffeners in the GFRP section's web (to prevent local buckling) are presented. ‎The GFRP profiles‎ were connected to the concrete deck slab by shear connectors. Two full-scale simply supported ‎composite beams (with and without stiffeners) were tested under impact load (three-point load) to ‎assess its structural response. The results ‎proved that the maximum impact force, maximum ‎deflection, damping time, and ‎damping ratio of the composite beam were affected by the GFRP ‎stiffeners‎. The experimental results indicated that the damping ratio and deflection were diminished compare

... Show More
View Publication Preview PDF
Crossref (13)
Crossref
Publication Date
Tue Sep 01 2015
Journal Name
Journal Of Engineering
Internal Convective Heat Transfer Effect on Iraqi Building Construction Cooling Load
...Show More Authors

This work involves the calculation of the cooling load in Iraqi building constructions taking in account the effect of the convective heat transfer inside the buildings. ASHRAE assumptions are compared with the Fisher and Pedersen model of estimation of internal convective heat transfer coefficient when the high rate of ventilation from ceiling inlet configuration is used. Theoretical calculation of cooling load using the Radiant Time Series Method (RTSM) is implemented on the actual tested spaces. Also the theoretical calculated cooling loads are experimentally compared by measuring the cooling load in these tested spaces. The comparison appears that using the modified Fisher and Pedersen model when large ventilation ra

... Show More
View Publication Preview PDF
Publication Date
Sun Apr 30 2017
Journal Name
Journal Of Engineering
Implementation of a Proposed Load-Shedding System Using Altera DE2 FPGA
...Show More Authors

A load-shedding controller suitable for small to medium size loads is designed and implemented based on preprogrammed priorities and power consumption for individual loads. The main controller decides if a particular load can be switched ON or not according to the amount of available power generation, load consumption and loads priorities. When themaximum allowed power consumption is reached and the user want to deliver power to additional load, the controller will decide if this particular load should be denied receiving power if its priority is low. Otherwise, it can be granted to receive power if its priority is high and in this case lower priority loads are automatically switched OFF in order not to overload the power generation. The

... Show More
View Publication Preview PDF