Reducing global warming potential (GWP) of refrigerants is needed to the decrease of ozone-depleting of refrigeration systems leakages. Refrigerant R1234yf is now used to substitute R134a inside mobile air conditioning systems. Thermodynamic properties of R1234yf are similar to R134a. Also, it has a very low GWP of 4, compared to 1430 for R134a, making it a proper choice for future automobile refrigerants. The purpose of this research is to represent the main operating and performance differences between R1234yf and R134a. Experimental analysis was carried out on the automotive air conditioning system (AACS) with 3 kW nominal capacity, to test and compare the performance of R134a with R1234yf. Experiments were accomplished for both refrigerants in almost the same working conditions and procedure with a range of ambient temperature varied from 26oC to 50oC. Parameters studied were ambient temperature, type of refrigerant in the system at compressor speed 1450 rpm, and internal thermal loads of passenger room. The performance characteristics of the system, including COP and cooling capacity, were studied by changing different parameters. The results show that COP of R134a is higher than R1234yf by 12.6%, while the refrigeration effect of R134a is higher than R1234yf by 25%. This shows that R1234yf is a suitable and good candidate for drop-in replacement of R134a in AACS.
In the present work the clathrate hydrate dissociation enthalpies of refrigerant R134a+ water system, and R134a + water + salt system were determined. The heat of dissociation of three types of aqueous salts solutions of NaCl, KBr and NaF at three concentrations (0.09, 0.17and 0.26) mol·kg−1 for each salt type, were enthalpy measured. The Clapeyron equation was used tocalculate heat of dissociation of experimental data for binary and ternary system.In order to find the effect of compressibility factor on heat dissociation enthalpy, the study was conducted by using equation of state proposed by Peng and Robinson Stryjek-Vera (PRSV). The obtained results of dissociation enthalpy for binary system were (143.8) kJ.mol-1
... Show MoreA time series analysis can help to observe the behavior of the system and specify the system faults. In addition, it also helps to explain the various energy flows in the system and further aid in reducing the thermodynamic losses. The intelligent supervisory LabVIEW software can monitor the incoming data from the system by using Arduino microcontroller and calculates the important parameters. Energy, exergy, and anergy analysis present in this paper to investigate the system performance as well as its components. To accomplish this, a 4-ton vertical split air conditioner based on vapor compression refrigeration cycle charged with refrigerant R-22 was modified for experimental analysis. The results showed that during 540
... Show MoreABSTRACT: BACKGROUND: Arthroscopic knee surgeries are performed in very large numbers worldwide, and in spite of relatively low complication rate, but the total number is significant. Some of these complications are due to tourniquet use and can be serious. OBJECTIVE: Is to asses if automated pump (with or without) dilute epinephrine saline irrigation can replace the tourniquet use in soft tissue arthroscopic knee surgeries. PATIENTS AND METHODS: 36 patients (9 females 25 % and 27 males 75 %) were included in this prospective experimental nonrandomized study, and were necessitated soft tissue arthroscopic knee surgeries. Patients were divided into two groups, in group A (patients) tourniquet and automated pump were used. In group B (18 pati
... Show MoreThe phenomenon of young people frequenting closed cafes spread in Baghdad to smoke hookahs and cigarettes has increased. This phenomenon is associated with unemployment, an increase in leisure time and the deterioration of economic conditions. This phenomenon has an impact on indoor air quality and exposes workers to the risk of exposure to various pollutants, including particulate matter, therefore, we examined some indicators (PM2.5, PM10) IAQ for a month in summer and another month in winter in six different locations in the Rusafa district. PM2.5 and PM10 concentrations, relative humidity (RH) and temperatures were measured using (Multifunction Air Quality Detector BENETECH -China). The results showed an increase in temperatures inside
... Show MoreThe effect of air injection angle on the performance of airlift pump used for water pumping has been studied analytically and experimentally. An airlift pump of dimensions 42mm diameter and 2200 mm length with conventional and modified air injection device was considered. A modification on conventional injection device (normal air-jacket type) was carried out by changing injection angle from 90 (for conventional) to 45 and 22.5 (for modified). Continuity and one-dimensional momentum balance for the flow field with basic principle of two-phase flow and expressions of slip ratio and friction factor as function of flow rates were formulated. The analytical and experimental investigations were carried out f
... Show MoreThis effort is related to describe and assess the performance of the Iraqi cement sample planned for oil well-cementing jobs in Iraq. In this paper, major cementing properties which are thickening time, compressive strength, and free water in addition to the rheological properties and filtration of cement slurry underneath definite circumstances are experimentally tested. The consequences point to that the Iraqi cement after special additives encounter the requests of the API standards and can consequently is used in cementing jobs for oil wells. At this research, there is a comparative investigation established on experimental work on the effectiveness of some additives that considered as waste materials which are silica fume, bauxite,
... Show MoreThis effort is related to describe and assess the performance of the Iraqi cement sample planned for oil well-cementing jobs in Iraq. In this paper, major cementing properties which are thickening time, compressive strength, and free water in addition to the rheological properties and filtration of cement slurry underneath definite circumstances are experimentally tested. The consequences point to that the Iraqi cement after special additives encounter the requests of the API standards and can consequently is used in cementing jobs for oil wells. At this research, there is a comparative investigation established on experimental work on the effectiveness of some additives that considered as waste materials which are silica fume, baux
... Show MoreThe present paper deals with experimental investigation of the performance of air cooled split air conditioner, with evaporative water mist pre cooling to increase the cooling capacity and reduce the consumption power under hot and dry climate. This investigation considers how the performance can be enhanced by using water mist to pre-cool ambient air entering the condensers by adiabatic cooling process which depends on the ambient air wet bulb temperature; as well the condensing temperature and condensing pressure will be decreased accordingly. So the cooling capacity would be increased and consumption power would be decreased, consequently the energy ratio, EER would be improved. The performance of air cooled air conditioner with water
... Show More