The phenomenon of young people frequenting closed cafes spread in Baghdad to smoke hookahs and cigarettes has increased. This phenomenon is associated with unemployment, an increase in leisure time and the deterioration of economic conditions. This phenomenon has an impact on indoor air quality and exposes workers to the risk of exposure to various pollutants, including particulate matter, therefore, we examined some indicators (PM2.5, PM10) IAQ for a month in summer and another month in winter in six different locations in the Rusafa district. PM2.5 and PM10 concentrations, relative humidity (RH) and temperatures were measured using (Multifunction Air Quality Detector BENETECH -China). The results showed an increase in temperatures inside closed cafes, exceeding the recommended limits, and regardless of the seasonal fluctuations, the average concentrations of both PM2.5 and PM10 inside closed cafes for the months of August and December exceeded the daily and annually PM standards recommended by World Health Organization for both PM2.5 and PM10 concentrations were higher in summer than in winter were the most of young people enjoy a long holiday. The peak of PM2.5 and PM10 concentrations also occurred during evening rush hour, more than the highest readings in the morning periods.
Shisha smoke represents one of the causes of indoor air pollution. Heavy metals represent the main components in shisha smoke. In this research study, the indoor concentrations of heavy metals in shisha smoke café sites was investigated, samples were taken from two café sites (site1, site 2) which differ in their volume. Site1 volume was 77m3, while site 2 was 437.5m3. Sample were taken by using a low volume sampler (sniffer), and then examined by the Atomic Absorption Spectrometry (AAS). The results showed that indoor air shisha smoke samples for both experimental sites have shown a significant amount of heavy metals as compared with control sampling values. The mean concentration values of (Pb, Zn, Co, Ni, Cr) in site 1 were (11.004,
... Show MoreFor cleaner air and unpolluted continue assessment study air pollution the city of
Baghdad by measuring the concentrations of air pollutants, which included TSP, Pb, where
the adoption of three stations (Andalus Square, Jadiriya, Allawi) are distributed in the city of
Baghdad in order to compare the concentrations of these pollutants with previous studies.
Study pointed out that the city's air contaminant, especially in minutes outstanding after
deducting the amount of atmospheric dust thick mechanism city this year where the highest
concentration of minutes outstanding (9895) micrograms / m 3 at the station Alawi and lower
concentration of 157 micrograms / m 3 at the station Alawi and this was higher than the
det
Air pollution evaluation of the operational processes in the East Baghdad oil field was carried out. The analysis was carried out by ICP-MS technique. Total Suspended Particles (TSP) air load was higher than Iraqi Standards and world international allowable limits of World Health Organization. The mean concentrations of gases carbon monoxide, carbon dioxide, sulfur dioxide, in the air were within national and world standards, while the mean concentration of nitrogen dioxide was higher than standard limits. The air of the study area is considered a good quality for CO, CO2 and NO2 with no health effect, while it is hazardous for TSP that have serious risk for people with respiratory disease. The mean concentrations of Cd, Cr, Cu and
... Show MoreThis paper describes a newly modified wind turbine ventilator that can achieve highly efficient ventilation. The new modification on the conventional wind turbine ventilator system may be achieved by adding a Savonius wind turbine above the conventional turbine to make it work more efficiently and help spinning faster. Three models of the Savonius wind turbine with 2, 3, and 4 blades' semicircular arcs are proposed to be placed above the conventional turbine of wind ventilator to build a hybrid ventilation turbine. A prototype of room model has been constructed and the hybrid turbine is placed on the head of the room roof. Performance's tests for the hybrid turbine with a different number of blades and different values o
... Show MoreIn this paper, the air pollutants concentrations measurements such as Total
Suspended Particles(TSP), Carbon Monoxides(CO),Carbon Dioxide (CO2) and
meteorological parameters including temperature (T), relative humidity (RH) and
wind speed & direction were conducted in Baghdad city by several stations
measuring numbered (22) stations located in different regions, and were classified
into (industrial, commercial and residential) stations. The results show that the
concentrations of pollutants (TSP, CO, and CO2) have exceeded the air quality
standards set by World Health Organization (WHO) and Iraqi limitation in the
stations of the Baghdad city. The program (ArcGIS) used to prepare maps of air
pollution in Ba
Aquatic Oligochaeta is an important group of Macroinvertebrates that has been very remarkable as bioindicators for assessing water pollution and determining its degree in water bodies. Hence, the idea of the current study aims at studying the impact of Baghdad effluents on the Tigris River by using oligochaetes community as bioindicators . For this purpose, four sites along the inside of Baghdad has been chosen. Site S1 has been located upstream, site S2 and S3 has been at midstream and site S4 at the downstream of the River.This investigation has used different types of biological indicators, including the percentage of oligochaeta within benthic invertebrates, which ranged from 49.2-51.28%. The highest percentage of the tubificid w
... Show MoreObjectives: To determine the (QoL) for patients with permanent pacemaker and to find-out the relationship between
these patients’ (QoL) and their sociodemographic characteristics such as age, gender, level of education, and
occupation.
Methodology: ٨ purposive non-probability” sample of (62) patient with permanent pacemaker was involved in this
study. The developed questionnaire consists of (4) parts which include !.demographic data form, 2.disease-related
information form, 3.socioeconomic data form, and 4.Permanent pacemaker patient’s quality of life questionnaire data
form. The validity and reliability of the questionnaire were determined through the application of a pilot study. ٨
descriptive statistical a
An infant incubator in the neonatal intensive care unit (NICU) is a medical instrument of care that provides oxygen, warmth and moisture to a newborn baby. Due to environmental conditions affecting the infants foster babies may experience discomfort and pain at some point. Thus, this study aimed to assess ambient air quality in neonatal incubators to improve the environmental quality of neonatal intensive care units and safety. Air pollutants concentrations consisting of particulate matter (pm2.5, pm10), hydrocarbons (HOCH), volatile organic compounds (VOC), air quality index (AQI), humidity and temperature, were measured at four selected Baghdad hospitals (Al-Karkh and Rusafa) . The results showed that the
... Show MoreIn this study water quality was indicated in terms of Water Quality Index that was determined through summarizing multiple parameters of water test results. This index offers a useful representation of the overall quality of water for public or any intended use as well as indicating pollution, water quality management and decision making. The application of Water Quality Index (WQI) with sixteen physicochemical water quality parameters was performed to evaluate the quality of Tigris River water for drinking usage. This was done by subjecting the water samples collected from eight stations in Baghdad city during the period 2004-2010 to comprehensive physicochemical analysis. The sixteen physicochemical parameters included: Turbidity,
... Show More