Background: Obesity is an evolving major health problem in both developed and developing countries. Traditional obesity indices as body mass index, waist circumference, waist-hip-ratio are well known measures to identify obese subjects, however, neck circumference as an index of upper-body obesity was found to be a simple and time-saving screening measure that can be used to identify obesity and the likelihood of developing metabolic syndrome in type 2 diabetic patients.
Aim: to investigate the relationship of neck circumference (NC) to obesity and metabolic syndrome in Iraqi subjects with type 2 diabetes.
Methods: The study group included 90 type 2 diabetic subjects (48 men and 42 women) aged 30-68 years. The subjects were those who attending The Specialized Center for Endocrinology and Diabetes/Baghdad. Main indicators studied included Neck Circumference (NC), waist circumference (WC), waist-to-hip ratio (WHR), body mass index (BMI), blood pressure, fasting blood glucose, and lipoprotein levels.
Results: Pearson's correlation coefficients indicated a significant association between NC and body circumference, and waist-hip-ren and from 0.014 to less than 0.0001 in women). Also NC is positively correlated with systolic blood pressure (SBP), diastolic blood pressure (DBP), triglycerides (TGA), fasting blood glucose level (p value from 0.092 to less than 0.0001). Cross tabulation between NC and BMI indicated that NC identified obese persons with 100% sensitivity in men and 90% in women, also a cross tabulation between NC and metabolic syndrome indicated that NC can identify metabolic syndrome with 100% sensitivity in both men and women. Metabolic syndrome was identified according to a modified criteria proposed by the National Cholesterol Education Program (NCEP) Adult Treatment Panel III (ATPIII).
mass index, waist atio (p <0.0001 in m
Conclusion: Neck circumference is positively correlated with BMI, waist circumference, waist-hip-ratio, and positively correlated with components of metabolic syndrome in Iraqi individuals with type 2 diabetes. Accordingly, the measurement of neck circumference could be useful in clinical screening for obese persons and for persons who are at risk of developing metabolic syndrome.
In this article, a numerical method integrated with statistical data simulation technique is introduced to solve a nonlinear system of ordinary differential equations with multiple random variable coefficients. The utilization of Monte Carlo simulation with central divided difference formula of finite difference (FD) method is repeated n times to simulate values of the variable coefficients as random sampling instead being limited as real values with respect to time. The mean of the n final solutions via this integrated technique, named in short as mean Monte Carlo finite difference (MMCFD) method, represents the final solution of the system. This method is proposed for the first time to calculate the numerical solution obtained fo
... Show MoreIn this paper the nuclear structure of some of Si-isotopes namely, 28,32,36,40Si have been studied by calculating the static ground state properties of these isotopes such as charge, proton, neutron and mass densities together with their associated rms radii, neutron skin thicknesses, binding energies, and charge form factors. In performing these investigations, the Skyrme-Hartree-Fock method has been used with different parameterizations; SkM*, S1, S3, SkM, and SkX. The effects of these different parameterizations on the above mentioned properties of the selected isotopes have also been studied so as to specify which of these parameterizations achieves the best agreement between calculated and experimental data. It can be ded
... Show MoreNanostructure of chromium oxide (Cr2O3-NPs) with rhombohedral structure were successfully prepared by spray pyrolysis technique using Aqueous solution of Chromium (III) chloride CrCl3 as solution. The films were deposited on glass substrates heated to 450°C using X-ray diffraction (XRD) shows the nature of polycrystalline samples. The calculated lattice constant value for the grown Cr2O3 nanostructures is a = b = 4.959 Å & c = 13.594 Å and the average crystallize size (46.3-55.6) nm calculated from diffraction peaks, Spectral analysis revealed FTIR peak characteristic vibrations of Cr-O Extended and Two sharp peaks present at 630 and 578 cm-1 attributed to Cr-O “stretching
... Show MorePurpose: The research aims to estimate models representing phenomena that follow the logic of circular (angular) data, accounting for the 24-hour periodicity in measurement. Theoretical framework: The regression model is developed to account for the periodic nature of the circular scale, considering the periodicity in the dependent variable y, the explanatory variables x, or both. Design/methodology/approach: Two estimation methods were applied: a parametric model, represented by the Simple Circular Regression (SCR) model, and a nonparametric model, represented by the Nadaraya-Watson Circular Regression (NW) model. The analysis used real data from 50 patients at Al-Kindi Teaching Hospital in Baghdad. Findings: The Mean Circular Erro
... Show MoreThis work was included external morphological study of horse fly Tabanus indrae Hauser 1939 new record in Iraq, which belongs to family: Tabanidae order: Diptera. The study was involved the most important taxonomic external characters of the: head, thorax, abdomen and their appendages which are: antenna, maxillary palp, wings, legs, spotting in coloring pattern and female genitalia of abdomen
BACKGROUND: Keratoconus is a progressive non inflammatory bilateral (usually asymmetric) ectatic corneal disease characterized by paraxial stromal thinning ,weakening that lead to corneal surface distortion ,vision loss primarily from irregular astigmatism and myopia and secondly from corneal scar. OBJECTIVE: To evaluate visual and refractive outcomes after intracorneal continuous ring (ICCR) implantation combined with intrapocket corneal collagen cross linking in patient with keratoconus. Setting: Eye Specialty Private Hospital, Baghdad, Iraq. METHODS: This study assessed the results of implantation of Myoring ICCR combined with CXL in 40 eyes with KC. Outcome measures include UDVA,CDVA(spectacle correction),refraction, complications and s
... Show MoreStatic loads exposing to mechanical components can cause cracks, which are lead to form stress concentration regions causing the failure of structure. Generally, from 80% to 90% of structure failure is due to initiation of the cracks. Therefore, it is necessary to repair the crack and reduce its effect on the structure where the effect of the crack is modelled as an additional flexibility to the structure. In the last few years, piezoelectric materials have been considered as one of the most favourable repairing techniques. The piezoelectric material converts the applied voltage on it to a bending moment to counter the bending moment caused by the external load on the beam at the crack location. In this study, the design of the piez
... Show MoreThis work presents the construction of a test apparatus for air-conditioning application that is flexible in changing a scaled down adsorbent bed modules. To improve the heat and mass transfer performance of the adsorbent bed, a finned-tube of the adsorbent bed heat exchanger was used. The results show that the specific cooling power (SCP) and the coefficient of performance (COP) are 163 W/kg and 0.16, respectively, when the cycle time is 40 min, the hot water temperature is 90oC, the cooling water temperature is 30oC and the evaporative water temperature is 11.4oC.
This study relates to synthesis of bentonite-supported iron/copper nanoparticles through the biosynthesis method using eucalyptus plant leaf extract, which were then named E-Fe/Cu@B-NPs. The synthesised E-Fe/Cu@B-NPs were examined by a set of experiments involving a heterogeneous Fenton-like process that removed direct blue 15 (DB15) dye from wastewater. The resultant E-Fe/Cu@B-NPs were characterised by scanning electron microscopy, Brunauer–Emmet–Teller analysis, zeta potential analysis, Fourier transform infrared spectroscopy and atomic force microscopy. The operating parameters in batch experiments were optimised using Box–Behnken design. These parameters were pH, hydrogen peroxide (H2O2
... Show More