Back ground: Several devices with different physical bases have been developed for the clinical measurement of corneal thickness, they classified into 4 categories: Scheimpflug photography based, Slit –Scanning topography, optical coherence tomography (OCT) based and ultrasound (US) based.Objective:To evaluatethe precision of the new Scheimpflug –Placido disc corneal topography in measurement of corneal thickness and to compare the measured values with that obtained by US pachymetry.Methods: Setting of this study is Lasik center in Eye Specialty Private Hospital. Baghdad. Iraq.Eyes of healthy subjects were examined with the Sirius topography.3 consecutive measurements of central (CCT)and thinnest (TCT) corneal thicknesses were obtainedand the measurements repeated within 1 week. The within –subject standard deviation (Sw),test-retest repeatability ,coefficient of variation (CoV),and interclass correlation coefficient (ICC) were calculated to evaluate intra session repeatability and intersession reproducibility. For US pachymetry (Tomey-SP 100) only CCT was measured. Comparison ofthe measurements that obtained by the 2 devices done by paired t-test.Results: The topography provides high intrasession repeatability with test-retest and CoV close to 6μm and0.4%, respectively for both CCT and TCT. The inter session reproducibility also high with test-retest and CoV close to 8μm and 0.5%, respectively.ICC was higher than 0.97 for repeatability and reproducibility . Anarrow 95% limit of agreement was found between the pachymetry obtained by topography and US pachymetry measurements.Conclusions :The topography has been used showed high intrasession repeatability and intersession reproducibility of CCT and TCT measurements in healthy eyes .Absence of statistically significant differences suggest that the topography -TCT and the US pachymetry - CCT can be used interchangeably in subject with normal cornea.Financial Disclosure: No financial or proprietary interest in any material or method mentioned.
Near-ideal p-CdS/n-Si heterojunction band edge lineup has been investigated for the first time with aid of I-V and C-V measurements. The heterojunction was manufactured by deposition of CdS films prepared by chemical spray pyrolysis technique (CSP) on monocrystalline n-type silicon. The experimental data of the conduction band offset Ec and valence band offset Ec were compared with theoretical values. The band offset Ec=530meV and Ev=770meV obtained at 300K. The energy band diagram of p-CdS/n-Si HJ was constructed. C-V measurements depict that the junction was an abrupt type and the built-in voltage was determined from C-2-V plot
In this report Silver doped Tin Sulfide (SnS) thin films with ratio of (0.03) were prepared using thermal evaporation with a vacuum of 4*10-6 mbar on glass with (400) nm thickness and the sample annealing with ( 573K ). The optical constants for the wavelengths in the range (300-900) nm and Hall effect for (SnS and SnS:3% Ag) films are investigated and calculated before and after annealing at 573 K. Transition metal doped SnS thin films the regular absorption 70% in the visible region, the doping level intensification the optical band gap values from 1.5- 2 eV. Silver doped tin sulfide (SnS) its direct optical band gap. Hall Effect results of (SnS and SnS:3% Ag) films show all films were (p-type) electrical conductivity with resistivity of
... Show MoreExperimental measurements of viscosity and thermal conductivity of single layer of graphene . based DI-water nanofluid are performed as a function of concentrations (0.1-1wt%) and temperatures between (5 to 35ºC). The result reveals that the thermal conductivity of GNPs nanofluids was increased with increasing the nanoparticle weight fraction concentration and temperature, while the maximum enhancement was about 22% for concentration of 1 wt.% at
35ºC. These experimental results were compared with some theoretical models and a good agreement between Nan’s model and the experimental results was observed. The viscosity of the graphene nanofluid displays Newtonian and Non-Newtonian behaviors with respect to nanoparticles concen
Solar hydrogen line emission has been observed at the frequency of 1.42 GHz (21 cm wavelength) with 3m radio telescope installed inside the University of Baghdad campus. Several measurements related to the sun have been conducted and computed from the radio telescope spectrometer. These measurements cover the solar brightness temperature, antenna temperature, solar radio flux, and the antenna gain of the radio telescope. The results demonstrate that the maximum antenna temperature, solar brightness temperature, and solar flux density are found to be 970 K, 49600K, and 70 SFU respectively. These results show perfect correlation with recent published studies.
The second leading cause of death and one of the most common causes of disability in the world is stroke. Researchers have found that brain–computer interface (BCI) techniques can result in better stroke patient rehabilitation. This study used the proposed motor imagery (MI) framework to analyze the electroencephalogram (EEG) dataset from eight subjects in order to enhance the MI-based BCI systems for stroke patients. The preprocessing portion of the framework comprises the use of conventional filters and the independent component analysis (ICA) denoising approach. Fractal dimension (FD) and Hurst exponent (Hur) were then calculated as complexity features, and Tsallis entropy (TsEn) and dispersion entropy (DispEn) were assessed as
... Show MoreCopper and Zinc powders with different particle sizes were subjected to sieving of range (20-100?m) and He-Ne laser system to determine the particle size . 1wt% from each powders was blended carefully with 99wt% from Iraqi oil . Microscopic examination were carried for all samples to reveal the particle size distribution . XRF intensity measurements were conducted for all suspended samples , and the relation between XRF intensity and the particle size was found .
Background: Radiotherapy, is therapy using ionizing radiation in order to deliver an optimal dose of either particulate or electromagnetic radiation to a particular area of the body with minimal damage to normal tissues. The source of radiation may be outside the body of the patient (external beam irradiation) or it may be an isotope that has been implanted or instilled into abnormal tissue or a body cavity. Called also radiotherapy. The aim of work studies the relationship between the depth dose and the high photon xray energies (6MeV and 10MeV). Patients and methods: in our work, we studied the dose distribution in water phantom given at different depths (zero-18) cm deep at1cm intervals treated with different field size (5×5-,10×1
... Show MoreThe accurate 3-D coordinate's measurements of the global positioning systems are essential in many fields and applications. The GPS has numerous applications such as: Frequency Counters, Geographic Information Systems, Intelligent Vehicle Highway Systems, Car Navigation Systems, Emergency Systems, Aviations, Astronomical Pointing Control, and Atmospheric Sounding using GPS signals, tracking of wild animals, GPS Aid for the Blind, Recorded Position Information, Airborne Gravimetry and other uses. In this paper, the RTK DGPS mode has been used to create precise 3-D coordinates values for four rover stations in Baghdad university camp. The HiPer-II Receiver of global positioning system was used to navigate the coordinate value. The results wil
... Show MoreThe main goal of this work is to obtain the plasma electron temperature Te by optical emission spectroscopy of low pressure microwave argon plasma, as a function of working pressure and microwave power. A plasma system was designed and constructed in our laboratory using a magnetron of domestic microwave oven with power 800W without any commercial part. The applied voltage on the magnetron electrical circuit is changed for the purpose of obtaining the variable values of the microwave power. The spectral detection is performed with a spectrometer of wavelength range (200−1000nm). The working pressure and magnetron applied voltage were 0.3-3.0mbar and 180-240V, respectively. Two methods had been applied to estimate the electron temperatu
... Show MoreIn this work, Kinetic Phosphorescence Analyzer (KPA) has been used to measure the concentrations of uranium (UC) and Amorphous crystals (AMO) in urine samples of breast cancer patients in Baghdad. Additionally, a relation between UC and AMO with respect to patient's age has been deduced and studied.
Forty one urine samples of patients and five for healthy were taken from females lived in different residential area of Baghdad. The measured maximum UC value for urine samples of patients was 2.35 ± 0.053, the minimum value was 0.86 ± 0.034 μg/L, and an overall average was 1.6 ± 0.027 μg/L while the average UC for healthy females was 1.03 ± 0.020 μg/L.
From these results, AMO concentrations were found for all breast cancer patie