Background: The purpose of this study was to compare regional bond strength at middle and cervical thirds of the root canal among glass fiber-reinforced composite (FRC) endodontic posts cemented with different cements, using the push-out test to compare the performance (retention) of two types of luting cements; polycarboxylate cement and Zinc phosphate cement used to cement translucent fiber post and to compare the result of the push-out test at different storage times;1 week ,1month and 2 months. Materials and methods: Ninety caries-free, recently extracted single-rooted human teeth with straight root canals was used in this study, The root canals were endodontically instrumented at a working length of 0.5 mm from the apex by means of conventional instruments for hand use (Dentsply, Switzerland) up to size 35.then root canal filling was performed followed by post space preparation up to 8mm including cervical and middle one third of root canal then the fiber post was cemented into canal post space then the root was sectioned to get cervical (4 mm in length) and middle (4 mm in length) thirds ,these thirds were examined by push out test to get values of retention of fiber post inside these canal thirds . Results and Conclusions: The results of this study has been showed that there was no significant differences between push out bond strength between fiber post and root at cervical third as compared with middle third when using polycarboxylate cement or Zinc phosphate cement to cement the fiber post to the canal walls and the results showed that there was no significant differences in push out bond strength for polycarboxylate or Zinc phosphate cement after one and two months but there was highly significantly increase in push out bond strength for resin cements used to cement the fiber post to the root canal after one and two months
This paper presents a numerical simulation of the flow around elliptic groynes by using CFD software. The flow was simulated in a flume with 4m long, 0.4m wide, and 0.175m high with a constant bed slope. Moreover, the first Groyne placed at 1m from the flow inlet with a constant the Groyne height of 10cm and a 1cm thickness, and the width of Groynes equals 7cm. A submergence ratio of the elliptic Groynes of 75% was assumed, corresponding to a discharge of 0.0057m3/sec. The CFD model showed a good ability to simulate the flow around Groynes with good accuracy. The results of CFD software showed that when using double elliptic Groy
... Show MoreBackground. After tooth extraction, alveolar bone resorption is inevitable. This clinical phenomenon challenges dental surgeons aiming to restore esthetic and function. Alveolar ridge preservation can be applied to minimize dimensional changes with a new socket grafting material, an autogenous dentin graft, produced by mechanically and chemically processing natural teeth. This study assessed the safety and efficacy of using autogenous dentin biomaterial in alveolar ridge preservation. Materials and Methods. Patients with nonrestorable maxillary anterior teeth bounded by natural sound teeth were included in this study. After a detailed clinical and tomographic examination, eligible participants were randomly allocated into two groups
... Show More
This paper describes DC motor speed control based on optimal Linear Quadratic Regulator (LQR) technique. Controller's objective is to maintain the speed of rotation of the motor shaft with a particular step response.The controller is modeled in MATLAB environment, the simulation results show that the proposed controller gives better performance and less settling time when compared with the traditional PID controller.
The optimization calculations are made to find the optimum properties of combined quadrupole lens consist of electrostatic and magnetic lenses to produce achromatic lens. The modified bell-shaped model is used and the calculation is made by solving the equation of motion and finding the transfer matrices in convergence and divergence planes, these matrices are used to find the properties of lens as the magnification and aberrations coefficients. To find the optimum values of chromatic and spherical aberrations coefficients, the effect of both the excitation parameter of the lens (n) and the effective length of the lens into account as effective parameters in the optimization processing
Present study was carried out to find prevalence of MRSA in healthy individual of second stage students, college of pharmacy/Baghdad University. A total of 74 student selected between age 18-23 years old were included in this study, nasal swabs collected and subjected to many diagnostic standard bacteriological identification methods. Culture, colonial morphology, Gram stain, mannitol fermentation, coagulase ,gelatinasetest, DNAase, MR/VP and antimicrobial susceptibility test was performed on tryptic soy agar by modified Kirby-Bauer muller hinton disc diffusion method and the result show that out of 74 nasal swabs,67(90.5%) were MRSA positive isolates, 21(31.4%) of them were mannitol ferment and 46(68.6%) non mannitol fermenter, am
... Show MoreThe main goal of this paper is to introduce the higher derivatives multivalent harmonic function class, which is defined by the general linear operator. As a result, geometric properties such as coefficient estimation, convex combination, extreme point, distortion theorem and convolution property are obtained. Finally, we show that this class is invariant under the Bernandi-Libera-Livingston integral for harmonic functions.