Preferred Language
Articles
/
jbcd-1507
Immediate Implant Placement in Fresh Extraction Socket
...Show More Authors

Background: In the traditional protocol, the patient should wait after extraction up to six months to place the dental implant in healed bone, this waiting time accompanied by varying degrees of alveolar bone changes. In order to overcome these problems, immediate implant placement in the fresh extraction socket was introduced. The Aim of this study was to evaluate the outcome of the immediate implant placement utilizing Resonance Frequency Analysis (RFA) to quantify implant stability and osseointegration. Materials and Methods: A total of (23) patients participated in the study, receiving (44) implants placed in the sockets of teeth indicated for extraction. Clinical and radiographic preoperative assessment was accomplished for each patient, β-TCP (combined with collagen membrane) was used to fill gaps ≥ (2 mm) and to repair bone defects. Implant stability quotient (ISQ) values were measured for the implants at baseline and at 16 weeks. Postoperative clinical and radiographic evaluation was applied for each patient. Results: A total of (22) patients received (41) implants completed the follow-up period, all these implants survived (100% survival rate) with no signs and symptoms of failure. The mean of ISQ value at baseline was (65.32±9.50), the mean of ISQ value at 16 weeks was (69.78±7.15), paired samples statistic showed high significant increase in the implant stability (P<0.01). Application of guided bone regeneration (GBR) showed no significant difference on ISQ value at baseline and at (16 weeks), but ISQ values increased significantly in GBR cases during the healing period. Conclusions: Immediate implant placement is a predictable treatment approach; it has the benefit of reducing treatment time and the numbers of surgical procedures when careful preoperative examination and appropriate intraoperative protocol is applied.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jul 01 2019
Journal Name
Journal Of Craniofacial Surgery
Effect of Platelet-Rich Fibrin and Bone Morphogenetic Protein on Dental Implant Stability
...Show More Authors

Abstract: Recombinant human bone morphogenetic protein-2 (rhBMP-2) and platelet-rich fibrin (PRF) bioactive materials have been used to enhance healing and improve dental implant stability. This study aimed to compare the effect of rhBMP-2 and PRF bioactive materials on dental implant stability at different intervals and to evaluate the correlation of implant length and diameter with implant stability. Two bioactive materials were compared to evaluate their effect on dental implant stability. A total of 32 patients (102 dental implants) were divided into 3 groups: 24 dental implants with bone morphogenetic protein (BMP), 27 dental implants with PRF, and 51 dental implants without BMP or PRF (control group). Data were statistically analyzed

... Show More
View Publication
Scopus (16)
Crossref (19)
Scopus Clarivate Crossref
Publication Date
Mon Jul 01 2019
Journal Name
Iop Conference Series: Materials Science And Engineering
Corrosion protection of pure titanium implant by electrochemical deposition of hydroxyapatite post-anodizing
...Show More Authors

In this study, a Hydroxyapatite (HA) coating was prepared on a titanium implant by an electrochemical deposition process. The titanium pre-treatment by anodizing in 1.65 mol/L sulfuric acid with (10V) at room temperature. The deposition was all conducted at a constant voltage of 6.0 V, for 1 h at room temperature. The coatings thus prepared were characterized with Fourier transform infrared spectroscopy (FTIR) and thickness of the coated layer.The electrochemical deposition of HA occurred on the titanium as a cathode. Coated titanium by HA after anodizing revealed a good corrosion protection efficiency even at a temperature ranged (293-323) K in artificial saliva. Activation energy and pre-exponential factor (kinetic parameters) were calcul

... Show More
View Publication Preview PDF
Scopus (13)
Scopus
Publication Date
Fri Jan 27 2012
Journal Name
Journal Of Huazhong University Of Science And Technology [medical Sciences]
An in vitro investigation into retention strength and fatigue resistance of various designs of tooth/implant supported overdentures
...Show More Authors

View Publication
Crossref (5)
Crossref
Publication Date
Fri Jun 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of Dental Implant Site Dimensions And Alveolar Bone Density in The Mandible Using Cone Beam Computed Tomography
...Show More Authors

Background: The quantity and the quality of available bone, influence the clinical success of dental implants surgery. Cone beam Computed tomography is an established method for acquiring bone images before performing dental implant. Cone beam computed tomography is an essential tool for treatment planning and post-surgical procedure monitoring, by providing highly accurate 3-D images of the patient's anatomy from a single, low-radiation scan which yields high resolution images with favorable accuracy. The aim of study is the Measurement of alveolar bone (height and buccolingual width) and density in the mandible among Iraqi adult subject using CBCT for assessment of dental implant site dimensions. Material and method: The study sample in

... Show More
View Publication
Crossref
Publication Date
Tue Jun 03 2025
Journal Name
Journal Of Baghdad College Of Dentistry
A Comparative Study between Flapped and Flapless Surgical Techniques in Dental Implant Stability According to Resonance Frequency Analysis
...Show More Authors

Background: Recent implant surgical approach aims to cause less trauma, invasiveness and pain as much as possible and to reduce patient and surgeon discomfort, time of surgery and time needed for functional implant loading. Flapless surgical techniques considered recently as one of the most popular techniques that may achieve these aims especially enhancing osseointegration and subsequently implant stability within less time than the traditional flapped surgical technique. So this study aimed to make a comparison between flapped and flapless surgical techniques in resulted implant stability according to resonance frequency analysis RFA and in duration of surgical operation. Materials and methods: A total of 26 patients with 41 implants (o

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Aug 23 2022
Journal Name
Journal Of Craniofacial Surgery
Differences Between Impression Stone Pouring and Digital Pouring in Fully Guided Dental Implant Surgery: A Prospective Clinical Study
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Sun Sep 04 2016
Journal Name
Baghdad Science Journal
Extraction conditions of polyphenol oxidase from banana peel
...Show More Authors

Polyphenol oxidase (PPO) is an enzyme containing copper, presents in various fruits and vegetables. It is responsible for the browning reactions when the cells are damaged during handling. The best conditions for extraction of polyphenol oxidase from banana peel was by using an extraction buffer containing phosphate buffer (0.05 M, pH 7), 0.01 M ascorbic acid and 0.5% polyethylene glycol, with extraction ratio 1:4 (w:v) for one minute by using blender. The enzyme activity was measured spectrophotometrically at 425 nm. PPO was studied to prevent the browning of banana peel which results in the loss of their marketability. The aim of this study was to determine the optimum conditions for polyphenol oxidase extraction from banana peel.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Jan 01 2018
Journal Name
Asian Journal Of Ournal Of Chemistry
Extraction of Ocimum basillicum Oil by Solvents Methods
...Show More Authors

The extraction of Basil oil from Iraqi Ocimum basillicum leaves using n-hexane and petroleum ether as organic solvents were studied and compared. The concentration of oil has been determined in a variety of extraction temperatures and agitation speed. The solvent to solid ratio effect has been studied in order to evaluate the concentration of Ocimum basillicum oil. The optimum experimental conditions for the oil extraction were established as follows: n-hexane as organic solvent, 60 °C extraction temperature, 300 rpm agitation speed and 40:1mL:g amount of solvent to solid ratio.

View Publication
Scopus (9)
Crossref (7)
Scopus Crossref
Publication Date
Wed Mar 30 2022
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Treatment of Used lubricant Oil by Solvent Extraction
...Show More Authors

This study investigates the treatment of used lubricating oils from AL-Mussaib Gas Power Station Company-Iraq, which was treated with different extractive solvents (heptane and 2-propanol). The performance activity of these solvents in the extraction process was examined and evaluated experimentally. Operating parameters were solvent to oil ratios of (1:2, 1:4, 1:6, and 1:8), mixing time (20, 35, 50, and 65 min), temperatures (30, 40, 50, and 60 ºC), and mixing speed (500 rpm). These parameters were studied and analyzed. The quality is determined by the measuring and assessment of important characteristics specially viscosity, viscosity index, specific gravity, pour point, flash point, and ash content. The results confirm that the solve

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Fri Apr 01 2022
Journal Name
Symmetry
Fast Overlapping Block Processing Algorithm for Feature Extraction
...Show More Authors

In many video and image processing applications, the frames are partitioned into blocks, which are extracted and processed sequentially. In this paper, we propose a fast algorithm for calculation of features of overlapping image blocks. We assume the features are projections of the block on separable 2D basis functions (usually orthogonal polynomials) where we benefit from the symmetry with respect to spatial variables. The main idea is based on a construction of auxiliary matrices that virtually extends the original image and makes it possible to avoid a time-consuming computation in loops. These matrices can be pre-calculated, stored and used repeatedly since they are independent of the image itself. We validated experimentally th

... Show More
View Publication
Scopus (22)
Crossref (19)
Scopus Clarivate Crossref