Background: In the traditional protocol, the patient should wait after extraction up to six months to place the dental implant in healed bone, this waiting time accompanied by varying degrees of alveolar bone changes. In order to overcome these problems, immediate implant placement in the fresh extraction socket was introduced. The Aim of this study was to evaluate the outcome of the immediate implant placement utilizing Resonance Frequency Analysis (RFA) to quantify implant stability and osseointegration. Materials and Methods: A total of (23) patients participated in the study, receiving (44) implants placed in the sockets of teeth indicated for extraction. Clinical and radiographic preoperative assessment was accomplished for each patient, β-TCP (combined with collagen membrane) was used to fill gaps ≥ (2 mm) and to repair bone defects. Implant stability quotient (ISQ) values were measured for the implants at baseline and at 16 weeks. Postoperative clinical and radiographic evaluation was applied for each patient. Results: A total of (22) patients received (41) implants completed the follow-up period, all these implants survived (100% survival rate) with no signs and symptoms of failure. The mean of ISQ value at baseline was (65.32±9.50), the mean of ISQ value at 16 weeks was (69.78±7.15), paired samples statistic showed high significant increase in the implant stability (P<0.01). Application of guided bone regeneration (GBR) showed no significant difference on ISQ value at baseline and at (16 weeks), but ISQ values increased significantly in GBR cases during the healing period. Conclusions: Immediate implant placement is a predictable treatment approach; it has the benefit of reducing treatment time and the numbers of surgical procedures when careful preoperative examination and appropriate intraoperative protocol is applied.
Background: The insertion torque (IT) values and implant stability quotient (ISQ) values are the measurements most used to assess primary implant stability. This study aimed to assess the relationship between ISQ values and IT. Materials and methods: This study included 24 patients with a mean (SD) age of 47.9 (13.64) years (range 25-75 years). The patients received 42 dental implants (DI), 33 in the mandible and 9 in the maxilla. The DI were installed using the motorized method with 35 Ncm torque, When DI could not be inserted to the requisite depth by the motorized method, a hand ratchet was used and the IT was recorded as ˃ 35 Ncm. Implant stability was measured utilizing Osstell® ISQ. The secondary stability was measured after 16
... Show MoreObjectives To assess the feasibility and accuracy of a new prototype robotic implant system for the placement of zygomatic implants in edentulous maxillary models. Methods The study was carried out on eight plastic models. Cone beam computed tomographs were captured for each model to plan the positions of zygomatic implants. The hand-eye calibration technique was used to register the dynamic navigation system to the robotic spaces. A total of 16 zygomatic implants were placed, equally distributed between the anterior and the posterior parts of the zygoma. The placement of the implants (ZYGAN®, Southern Implants) was carried out using an active six-jointed robotic arm (UR3e, Universal Robots) guided by the dynamic navigation coordinate tran
... Show MoreThe aim of this study was to compare the effect of conventional implant site preparation technique and a combination of conventional/piezosurgery preparation on implant stability measured at different time intervals, insertion torque, and preparation time. A randomized controlled study was designed, it included 26 patients who received 54 dental implants randomly assigned to 2 groups; in the control group, implants were installed after conventional preparation with drills whereas the study group received implants after mixed conventional/piezosurgery preparation. The outcome variables included: implant stability measured immediately after implant insertion, at 8 weeks and 16 weeks postoperatively, insertion torque and preparation time. All
... Show MoreThe accumulation of toxic elements in vegetables and melons grown in agriculture, Brassica rapa - turnip, Solanum lycopersicum - tomato, Citrullus lanatus - watermelon, Capsicum annuum - bell pepper, Daucus carota - carrots, Cucurbita pepo - pumpkin, Cucumis melo - melon, and also Prunus armeniaca - apricot from fruit trees were analyzed. The excess of maximum allowable concentrations in agricultural crops of the element As by 1.65-1.75, Cd - 1.6-2.3, Cr -1.2-2.35, Cu -1.6-3.3, Ni - 1.16-3.53, Pb - 1.54-3.08, Al - 1.36-3.5, Sb - 2.0-33, Se - 1.1-3.3 times was established. The maximum allowable concentration of mercury in vegetables and melons was equal to 0.02 mg/kg,
... Show MoreUtilizing phase change materials in thermal energy storage systems is commonly considered as an alternative solution for the effective use of energy. This study presents numerical simulations of the charging process for a multitube latent heat thermal energy storage system. A thermal energy storage model, consisting of five tubes of heat transfer fluids, was investigated using Rubitherm phase change material (RT35) as the. The locations of the tubes were optimized by applying the Taguchi method. The thermal behavior of the unit was evaluated by considering the liquid fraction graphs, streamlines, and isotherm contours. The numerical model was first verified compared with existed experimental data from the literature. The outcomes re
... Show MoreThe prostheses sockets use normally composite materials which means that their applications may be related with the human body. Therefore, it was very necessary to improve the mechanical properties of these materials. The prosthetic sockets are subjected to varying stresses in gait cycle scenario which may cause a fatigue damage. Therefore, it is necessary or this work to modify the fatigue behavior of the materials used for manufacturing the prostheses sockets. In this work, different Nano particle materials are used to modify the mechanical properties of the composite materials, and increase the fatigue strength. By using an experimental technique, the effect of using different volu
Most researchers concentrate their studies on the design, stress and pressure distributions of the prosthetic socket. A little attention is considered for the stiffness of the various materials of the prosthetic sockets. Prosthetic laminated sockets in Iraq are costly to be manufactured while polypropylene socket is relatively cheap in comparing with the laminates.
Experimental study is conducted to compare the stiffness of five prosthetic sockets made of different materials. Compression, three point flexural and tensile tests are implemented by the Testometric machine. The laminate sockets give better results in compression than polypropylene. Polypropylene gives good results in bending compared with the laminate sockets. When t
... Show MoreThis study was aimed to investigate the load of bacterial contaminant in fresh meat with different types of bacteria.One handered and seven samples were collected from different regions of Baghdad . These samples included 37 of fresh beef 70 of fresh sheep meat. All samples were cultured on different selective media to identitfy of contaminated bacteria .The result revealed that The percentage of bacterial isolate from raw sheep meat were, % 23.8of StreptococcusgroupD,29.4 % of Staphylococcus aureus ,14.7 % of E.coli , %4.9of Salmonella spp, ,%3.5 of pseudomonas aeruginosa, %14.7.%14.7 of Proteus spp.% 2.1 of Listeria spp while the raw beef meat content %5.55 of Staphylococcus aureus, %8.14 of streptococcus group D , %5.18 %1.85 of E.coli,
... Show MoreThe instant global trend towards developing tight reservoir is great; however, development can be very challenging due to stress and geomechanical properties effect in horizontal well placement and hydraulic fracturing design. Many parameters are known to be important to determine the suitable layer for locating horizontal well such as petrophysical and geomechanical properties. In the present study, permeability sensitivity to stress is also considered in the best layer selection for well placement. The permeability sensitivity to the stress of the layers was investigated using measurements of 27 core sample at different confining stress values. 1-D mechanical earth model (MEM) was built and converted to a 3-D full-field geomechanical mode
... Show More