Preferred Language
Articles
/
jbcd-1507
Immediate Implant Placement in Fresh Extraction Socket
...Show More Authors

Background: In the traditional protocol, the patient should wait after extraction up to six months to place the dental implant in healed bone, this waiting time accompanied by varying degrees of alveolar bone changes. In order to overcome these problems, immediate implant placement in the fresh extraction socket was introduced. The Aim of this study was to evaluate the outcome of the immediate implant placement utilizing Resonance Frequency Analysis (RFA) to quantify implant stability and osseointegration. Materials and Methods: A total of (23) patients participated in the study, receiving (44) implants placed in the sockets of teeth indicated for extraction. Clinical and radiographic preoperative assessment was accomplished for each patient, β-TCP (combined with collagen membrane) was used to fill gaps ≥ (2 mm) and to repair bone defects. Implant stability quotient (ISQ) values were measured for the implants at baseline and at 16 weeks. Postoperative clinical and radiographic evaluation was applied for each patient. Results: A total of (22) patients received (41) implants completed the follow-up period, all these implants survived (100% survival rate) with no signs and symptoms of failure. The mean of ISQ value at baseline was (65.32±9.50), the mean of ISQ value at 16 weeks was (69.78±7.15), paired samples statistic showed high significant increase in the implant stability (P<0.01). Application of guided bone regeneration (GBR) showed no significant difference on ISQ value at baseline and at (16 weeks), but ISQ values increased significantly in GBR cases during the healing period. Conclusions: Immediate implant placement is a predictable treatment approach; it has the benefit of reducing treatment time and the numbers of surgical procedures when careful preoperative examination and appropriate intraoperative protocol is applied.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Sep 04 2016
Journal Name
Baghdad Science Journal
Extraction conditions of polyphenol oxidase from banana peel
...Show More Authors

Polyphenol oxidase (PPO) is an enzyme containing copper, presents in various fruits and vegetables. It is responsible for the browning reactions when the cells are damaged during handling. The best conditions for extraction of polyphenol oxidase from banana peel was by using an extraction buffer containing phosphate buffer (0.05 M, pH 7), 0.01 M ascorbic acid and 0.5% polyethylene glycol, with extraction ratio 1:4 (w:v) for one minute by using blender. The enzyme activity was measured spectrophotometrically at 425 nm. PPO was studied to prevent the browning of banana peel which results in the loss of their marketability. The aim of this study was to determine the optimum conditions for polyphenol oxidase extraction from banana peel.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Jan 01 2018
Journal Name
Asian Journal Of Ournal Of Chemistry
Extraction of Ocimum basillicum Oil by Solvents Methods
...Show More Authors

The extraction of Basil oil from Iraqi Ocimum basillicum leaves using n-hexane and petroleum ether as organic solvents were studied and compared. The concentration of oil has been determined in a variety of extraction temperatures and agitation speed. The solvent to solid ratio effect has been studied in order to evaluate the concentration of Ocimum basillicum oil. The optimum experimental conditions for the oil extraction were established as follows: n-hexane as organic solvent, 60 °C extraction temperature, 300 rpm agitation speed and 40:1mL:g amount of solvent to solid ratio.

View Publication
Scopus (9)
Crossref (7)
Scopus Crossref
Publication Date
Sun Mar 13 2011
Journal Name
Baghdad Science Journal
Extraction and Purification of albumin from Hunan plasma
...Show More Authors

This study includes adescription of Human serum Albumin by amodified using ion- exchange chromatography with manipulated comparison with cold ethanol precipitation method , It has been nticed that this procedure is superior orer the classical method . The Final yield by the new method 69.32% with purity of 83.42% compared with cohn which yield 60.30 % with purity of 80.7 % . The new method prored that it suitable for the pusi Fication of such material because it yield no precipitation material and it increases the Final yield of albumin solutions . • Human serum Albumin . • Albumin purification . • Ion – exchange chromatography . • Human plasma . • Albumin extraction .

View Publication Preview PDF
Crossref
Publication Date
Wed Mar 30 2022
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Treatment of Used lubricant Oil by Solvent Extraction
...Show More Authors

This study investigates the treatment of used lubricating oils from AL-Mussaib Gas Power Station Company-Iraq, which was treated with different extractive solvents (heptane and 2-propanol). The performance activity of these solvents in the extraction process was examined and evaluated experimentally. Operating parameters were solvent to oil ratios of (1:2, 1:4, 1:6, and 1:8), mixing time (20, 35, 50, and 65 min), temperatures (30, 40, 50, and 60 ºC), and mixing speed (500 rpm). These parameters were studied and analyzed. The quality is determined by the measuring and assessment of important characteristics specially viscosity, viscosity index, specific gravity, pour point, flash point, and ash content. The results confirm that the

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Fri Apr 01 2022
Journal Name
Symmetry
Fast Overlapping Block Processing Algorithm for Feature Extraction
...Show More Authors

In many video and image processing applications, the frames are partitioned into blocks, which are extracted and processed sequentially. In this paper, we propose a fast algorithm for calculation of features of overlapping image blocks. We assume the features are projections of the block on separable 2D basis functions (usually orthogonal polynomials) where we benefit from the symmetry with respect to spatial variables. The main idea is based on a construction of auxiliary matrices that virtually extends the original image and makes it possible to avoid a time-consuming computation in loops. These matrices can be pre-calculated, stored and used repeatedly since they are independent of the image itself. We validated experimentally th

... Show More
View Publication
Scopus (23)
Crossref (19)
Scopus Clarivate Crossref
Publication Date
Wed Mar 30 2022
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Treatment of Used lubricant Oil by Solvent Extraction
...Show More Authors

This study investigates the treatment of used lubricating oils from AL-Mussaib Gas Power Station Company-Iraq, which was treated with different extractive solvents (heptane and 2-propanol). The performance activity of these solvents in the extraction process was examined and evaluated experimentally. Operating parameters were solvent to oil ratios of (1:2, 1:4, 1:6, and 1:8), mixing time (20, 35, 50, and 65 min), temperatures (30, 40, 50, and 60 ºC), and mixing speed (500 rpm). These parameters were studied and analyzed. The quality is determined by the measuring and assessment of important characteristics specially viscosity, viscosity index, specific gravity, pour point, flash point, and ash content. The results confirm that the solve

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Thu Jun 05 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Localization of transforming growth factor-beta expression in the peri-implant tissues of dental implants coated with placental collagen
...Show More Authors

Back ground : The transforming growth factor beta (TGFB) signaling pathway is involved in many cellular processes in both the adult organism and the developing embryo including cell growth, cell differentiation, apoptosis. The interaction between implant material and surrounding tissues is believed to play a fundamental role in implant success and illustrates different expression of growth factors by different cells that involved in the formation of peri-implant tissue. The aim of this study was to localize expression of TGF B by newly formed bone tissue around surface-conditioned implants with placental collagen at different time intervals: 3 ,7,14,28, and 56 days . Materials and Methods: Commercially pure Titanium (CPTi) implants coated w

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 04 2024
Journal Name
Journal Of Emergency Medicine, Trauma And Acute Care
Cone beam computed tomography (CBCT) evaluation of ridge shape and bone density in Iraqi sample pre-dental implant insertion
...Show More Authors

One of the critical factors for dental implant success is accurate clinical and radiological assessment. Cone-beam computed tomography systems (CBCT) allow surgeons to determine the quality and quantity before surgery, aiding in treatment planning. This study highlights the importance of such an assessment Materials and Methods A total of 40 patients were referred to CBCT scanning for pre-dental implant assessment in the Oral and Maxillofacial Radiology department at Al-Shaheed Gazi Al Hariri Hospital from 2021 to 2022. The patients were between 18 and 50 years old. All data were analyzed with on-demand 3D software (Kavo OP 3D: Cone Beam 3D imaging Germany). Results: Regarding the ridge shape: In the upper anterior and posterior regions, th

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Tue Jun 01 2021
Journal Name
International Medical Journal
Surface analysis of the PEKK coating on the cp ti implant using laser technique
...Show More Authors

Objective: Evaluation of the poly ether keton keton polymer (PEKK) coating material on the commercial pure titanium disks (CP Ti) with or without laser surface structuring. Design: In vitro experimental study of PEKK polymer coated material on the CP Ti disks with or without laser surface structuring. Materials and methods: coating the surface of the commercial pure titanium (CP Ti) disks with PEKK polymer was performed via using frictional mode CO2 laser, then the samples disks analyzed by using FESEM. Results: the FESEM reveal good adherence and distribution of the PEKK coated material over the CP Ti substrate by using the frictional mode CO2 laser at 2 watt and 6 ms pulse duration. Conclusion: the frictional mode CO2 laser considered an

... Show More
Preview PDF
Scopus (7)
Scopus
Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Journal Of Laser
PDF Fiber Laser Effect on Bond Strength of Titanium implant abutment to Resin Cement
...Show More Authors

Aim: surface modification of titanium using fiber laser 1064 nm to enhance the bond strength to resin cement. Material and Methods: thirty titanium discs of 0.6 cm x 0.3 cm (diameter and thickness respectively) were categorized after preparation into three groups (n=10) as follows: control group with no surface treatment and two test groups were treated with fiber laser after estimation the appropriate parameters in the pilot study which are 81 ns pulse duration, 30,000 Hz frequency, 50 µm spot size and 10,000 mm/s scanning speed and different average power values (10 W and 20 W) depending on the tested group. Titanium discs surface characterization was performed by scanning electron microscope (SEM), a

... Show More
View Publication Preview PDF