Background: The purpose of this study was to verify the influence of post- pressing time of acrylic resin (immediate, 6, 12 and 24 hour) on the dimensional accuracy of denture base whish is a critical factor in the retention and stability of the complete denture that may occur during polymerization shrinkage. Materials and Methods: Forty maxillary stone casts were poured in plastic mold (Columbia Dentoform corp. NEW YORK, type III dental stone (Geastone, Zeus Sri Loc.Tamburine Roccastrada, GR, Italy). The stone casts were randomly assigned into 4 groups of 10 specimens each according to the post-pressing times into (immediate, 6, 12 and 24 h.). Heat cure acrylic resin denture base was constructed according to the previously mentioned pressing time, the resin base-stone cast sets were transversally sectioned with a manual saw device at the distal aspect of the molar area, anterior to the posterior palatal seal area. The gap between the resin base and stone cast was measured at five points in the right (point B) and left (point D) ridge crests, at the midline (point C), and at the right (point A) and left (point E) marginal limits (A), using a Leitz linear optical comparator microscope with a travelling stage capable of measuring 0.001 mm. Each measurement was repeated three times and the average was used as the linear gap distance for that point. The data were submitted to ANOVA. Result: there was statistically significant difference between the pressing time in which the mean values of gap space in point E for 24h shows lowest value then point A, point B, and point D than the other post pressing time. The mean value in point C shows highest values which mean the greater gap space in palatal area.
Background: The presence of anatomic variations within the maxillary sinus such as septa has been reported to increase the risk of sinus membrane perforation during sinus elevation procedure for implant placement. This study aimed to measure the septal heights and correlate it with different types of septa. Material and methods: Thirty patients (15 males and 15 females) with partially edentulous maxillae and mean age (35) years were enrolled in this study. Sixty sinuses scanned with Spiral multislice Computed Tompgraphy, septal height measured after evaluation of septal type whether it was primary or secondary. Results: The results showed that 72.5 % of the septa detected were primary and this is statistically significant when compared w
... Show MoreThis work is concerned with the design and performance evaluation of a shell and double concentric tubes heat exchanger using Solid Works and ANSY (Computational Fluid Dynamics).
Computational fluid dynamics technique which is a computer-based analysis is used to simulate the heat exchanger involving fluid flow, heat transfer. CFD resolve the entire heat exchanger in discrete elements to find: (1) the temperature gradients, (2) pressure distribution, and (3) velocity vectors. The RNG k-ε model of turbulence is used to determining the accurate results from CFD.
The heat exchanger design for this work consisted of a shell and eight double concentric tubes. The number of inlets are three and that of o
... Show MoreResearch aimed to explore the Application Effect of the Conflict Management Strategies by the managements to solve conflict between and inside the conflicted parties within (IGEC) to increase the productivity of the workers. To collect data, 110 questioners had been distributed among managers and heads of departments of all managerial levels, 102 answered questioners regained, 5 of them were disqualify for statistical analytic, only 97 were taking in consideration for statistical analysis presenting 93% of the retained number.
SPSS Program supported with a group of statistical tools, had been used for analysis purposes such as Kronbach Alpha test to assure the validity & stability of the t
... Show MoreThe influence of adding metal foam fins on the heat transfer characteristics of an air to water double pipe heat exchanger is numerically investigated. The hot fluid is water which flows in the inner cylinder whereas the cold fluid is air which circulates in the annular gap in parallel flow with water. Ten fins of metal foam (Porosity = 0.93), are added in the gap between the two cylinder, and distributed periodically with the axial distance. Finite volume method is used to solve the governing equations in porous and non-porous regions. The numerical investigations cover three values for Reynolds number (1000 ,1500, 2000), and Darcy number (1 x10-1, 1 x10-2, 1x10-3). The comparison betwee
... Show MoreAims: This study aims to compare patients’ complaints and problems of wearing complete dentures.
Methodology: The sample included 40 Iraqi patients who are wearing complete dentures from about five years ago. They
were selected randomly with a age range between (55–65) years. The questions asked to the patients were listed according
to the recent classification of post-insertion problems.
Result: The results showed that the percentage of patient's complaint from adaptation problems (62.1%) was higher than
looseness problems (61.3%) and discomfort problems (39.3%) as followed.
Recommendation: Dentists need thorough knowledge of anatomy, physiology, pathology and psychology. The assessing
of the psyche and emotions
The main aim of this study is to assess the performance and residual strength of post-fire non-prismatic reinforced concrete beams (NPRC) with and without openings. To do this, nine beams were cast and divided into three major groupings. These groups were classified based on the degrees of heating exposure temperature chosen (ambient, 400, and 700°C), with each group containing three non-prismatic beams (solid, 8 trapezoidal openings, and 8 circular openings). Experimentally, given the same beam geometry, increasing burning temperature caused degradation in NPRC beams, which was reflected in increased mid-span deflection throughout the fire exposure period and also residual deflectio
Refrigerant R134a has been widely utilized in automotive air conditioning systems (AACSs); R134a has a high global warming potential (GWP) of 1430 despite having zero ozone depletion potential (ODP). Coming refrigeration systems must include refrigerants with low GWP and zero ODP. The aim of this experimental study is to evaluate the thermal performance of an (AAC) with different values of compressor speeds, i.e., (1000, 1700, and 2400 rpm) and two thermal loads, i.e., (500 and 1000 Watt) with the absence and presence of liquid suction heat exchanger (LSHX) using R134a. The results showed that adding LSHX enhanced the COP cycle by 7.18%, 10.7%, and 3.09% for the first, second, and third speed, respectively, at 500 Watt, while the en
... Show MoreThis study aims to assess the effect of adding twisted fins in a triple-tube heat exchanger used for latent heat storage compared with using straight fins and no fins. In the proposed heat exchanger, phase change material (PCM) is placed between the middle annulus while hot water is passed in the inner tube and outer annulus in a counter-current direction, as a superior method to melt the PCM and store the thermal energy. The behavior of the system was assessed regarding the liquid fraction and temperature distributions as well as charging time and energy storage rate. The results indicate the advantages of adding twisted fins compared with those of using straight fins. The effect of several twisted fins was also studied to discover
... Show MoreAn experimental and numerical investigation of the effect of using two types of nanofluids with suspending of (Al2O3 and CuO) nanoparticles in deionized water with a volume fraction of (0.1% vol.), in addition to use three types of fin plate configurations of (smooth, perforated, and dimple plate) to study the heat transfer enhancement characteristics of commercial fin plate heat sink for cooling computer processing unit. All experimental tests under simulated conditions by using heat flux heater element with input power range of (5, 16, 35, 70, and 100 W). The experimental parameters calculated are such as water and nanofluid as coolant with Reynolds number of (7000, 8000, 9400 and 11300); the air
... Show More