Preferred Language
Articles
/
injns-74
Evaluation and Comparison of Complete Dentures’ Complaints: Post-insertion
...Show More Authors

Aims: This study aims to compare patients’ complaints and problems of wearing complete dentures.
Methodology: The sample included 40 Iraqi patients who are wearing complete dentures from about five years ago. They
were selected randomly with a age range between (55–65) years. The questions asked to the patients were listed according
to the recent classification of post-insertion problems.
Result: The results showed that the percentage of patient's complaint from adaptation problems (62.1%) was higher than
looseness problems (61.3%) and discomfort problems (39.3%) as followed.
Recommendation: Dentists need thorough knowledge of anatomy, physiology, pathology and psychology. The assessing
of the psyche and emotions of patients is extremely complex long period study at the same patient will give the more about
this subject.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Dec 23 2024
Journal Name
Journal Of Baghdad College Of Dentistry
The Effects of Different Investment Materials on Dimensional Accuracy and Surface Roughness of Thermosens Maxillary Complete Dentures
...Show More Authors

Background: Limited data are available on the dimensional stability and surface roughness of ThermoSens, which is a material used in denture processing. This study aimed to measure the vertical teeth changes and surface roughness of ThermoSens dentures prepared using three different investment materials. Materials and methods: For the dimensional changes test, 30 complete maxillary dentures were prepared using different investment methods: group I, dental stone; group II, silicone putty; and group III, a mixture of dental stone and plaster (ratio, 1:1; n = 10 for each group). Four screws were attached to the dentures: two were attached to the buccal surface of the canine and first molar, and the other two were attached in the flange areas o

... Show More
View Publication Preview PDF
Publication Date
Thu May 05 2022
Journal Name
Al-kindy College Medical Journal
Safety profile of immediate post-partum intrauterine device insertion during caesarean delivery – a clinical trial with three years of follow up: Utility of Immediate Post Placental Insertion of Intrauterine Device During Cesarean Delivery
...Show More Authors

Background: Many countries recommend the use of long-acting reversible contraceptive intrauterine device immediately after cesarean delivery. The cesarean delivery rate in Iraqi public hospitals is 32.2% and may reach 85.8% in private hospitals. Immediate post-partum intrauterine device insertion at cesarean is rarely done in Iraq.

Objectives: To assess the safety and practicality of immediate post-partum intrauterine device insertion during cesarean delivery for family planning and pregnancy spacing in Iraqi women.

Subjects and Methods: A single arm clinical trial included 150 eligible women who attended Al-‎Elwiyah Maternity Teaching Hospital or Al Hayat Rahibat Hospita

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Dec 06 2009
Journal Name
Baghdad Science Journal
The influence of He-Ne Laser (632.8 nm) on Candida albicans isolated from complete upper dentures: In vitro study
...Show More Authors

The main objective of this study is to determine whether the use of He-Ne Laser (632.8 nm wavelength and power 0.5 mW) is an eligible and effective tool to kill or reduce the cell viability of Candida albicans isolated from complete upper dentures. Twenty one swabs were taken from the complete upper dentures. Only six swabs showed positive cultures for C. albicans. The isolate was divided into two groups, group I was not irradiated (control), and group II was irradiated by He-Ne Laser for different periods (10, 15, 20, and 30) min. After irradiation, the results showed a significant reduction in the viable cell count and colonies diameters especially at exposure periods 10 and 15 min. Although the low power He-Ne Laser was not eradicating t

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Dec 23 2024
Journal Name
Journal Of Baghdad College Of Dentistry
Effects of time delay and tension system application after final flask closure on the vertical displacement of acrylic and porcelain teeth in maxillary complete dentures
...Show More Authors

Background: The displacement of artificial teeth during complete denture construction presents major processing errors in the occlusal vertical dimension which were verified at the previous trial denture stage. The aim of this study was to assess the effect of delay in processing after final flask closure and tension application on the vertical acrylic and porcelain teeth displacement of complete dentures constructed from heat cured acrylic and the results were compared with the conventional processing method. Materials and methods: forty samples of identical maxillary complete dentures were constructed from heat polymerized acrylic resin. These samples were subdivided into the following experimental subgroups in which each subgroup contai

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 22 2020
Journal Name
Clinical And Experimental Dental Research
Prevalence and factors influencing reporting of true periodontal chief complaints: A retrospective analysis
...Show More Authors
Abstract<sec><title>Objectives

To investigate the prevalence of true periodontal chief complaints (CC) and the factors affecting their reporting by patients with periodontal diseases (PD).

Materials and Methods

This cross‐sectional study was based on retrospective analysis of available periodontal records. Different personal and demographic variables were obtained from these records including CC, age, gender, working status, past medical/dental history, smoking status and diagnosis. In addition, clinical parameters of plaque index, gingival index, probing pocket depth (PPD), and number of missing teeth. Periodontal CC were r

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Tue Mar 15 2022
Journal Name
Journal Of Baghdad College Of Dentistry
The relationship of implant stability quotient and insertion torque in dental implant stability
...Show More Authors

Background: The insertion torque (IT) values and implant stability quotient (ISQ) values are the measurements most used to assess primary implant stability. This study aimed to assess the relationship between ISQ values and IT. Materials and methods: This study included 24 patients with a mean (SD) age of 47.9 (13.64) years (range 25-75 years). The patients received 42 dental implants (DI), 33 in the mandible and 9 in the maxilla. The DI were installed using the motorized method with 35 Ncm torque, When DI could not be inserted to the requisite depth by the motorized method, a hand ratchet was used and the IT was recorded as ˃ 35 Ncm. Implant stability was measured utilizing Osstell® ISQ. The secondary stability was measured after 16

... Show More
View Publication Preview PDF
Crossref (2)
Scopus Crossref
Publication Date
Tue Jan 29 2019
Journal Name
Journal Of The College Of Education For Women
The vocal inspiration of expressing the complaints in the Qur'anic script
...Show More Authors

Thanks and gratefulness be to Allah , the most merciful , and prayers be on his messenger and our prophet mohammed and his descendants.The voices have great influence on the diversity of methods of complaints and implication in the Qur'anic expression through
their inspiration , forms and notes. They also have influence on performing semantic and psychological condition of the emitter . that is because of the connection between the complaints and human behavior and emotions , since it is considered as the outlet by which the human expresses his repressed desired and instincts . he resorted to it " when he is helpless physically and mentally i.e. he cannot reach his goals or satisfy his needs." Complaints come from deprivation , social

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 23 2024
Journal Name
Journal Of Baghdad College Of Dentistry
Comparison of fit among different types of post restorations luted with conventional cement
...Show More Authors

Background: with the advent of new postmaterial in dentistry, it has become important to measure fitness of post restoration along the horizontal plane of the root space.This study aimed to measure and compare, the cement film thickness of conventional zinc phosphate cement in micrometer between the post and root dentin along horizontal plane at different post space regions (coronal, middle and apical) of four types of posts, by using stereomicroscopy. Material and methods: Thirty-two extracted human maxillary canines, mandibular canines and maxillary central incisors (n=32) were instrumented with ProTaper system files (hand use) and obturated with gutta-percha for ProTaper and AH26® root canal sealer. After 24hrs of incubation at 37ºC, p

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 23 2024
Journal Name
Journal Of Baghdad College Of Dentistry
Comparison of regional bond strength of post space of fiber-reinforced post luted with two types of cements at different testing times
...Show More Authors

Back ground: This in vitro study was carried out to investigate the effect of post space regions (coronal, middle and apical), Time and the mode of polymerization (dual, self-cured) of the cements used on the bond strength between translucent fiber post and root dentin by using push-out test. Materials and Methods: Forty eight extracted mandibular first premolars (single root) were instrumented with ProTaper Universal system files (for hand use) and obturated with gutta percha for ProTaper and AH26® root canal sealer following the manufacturer instructions, after 24 hours post space was prepared using FRC postec® plus drills no.3 creating 8 mm depth post space. The prepared samples were randomly divided into two main groups (24 samples ea

... Show More
View Publication Preview PDF
Publication Date
Sun Jul 31 2022
Journal Name
Iraqi Journal Of Science
The generalized Cayley graph of complete graph K_n and complete multipartite graphs K_(n,n) and K_(n,n,n)
...Show More Authors

Suppose that  is a finite group and  is a non-empty subset of  such that  and . Suppose that  is the Cayley graph whose vertices are all elements of  and two vertices  and  are adjacent if and only if . In this paper, we introduce the generalized Cayley graph denoted by  that  is a graph with vertex set consists of all column matrices  which all components are in  and two vertices  and  are adjacent if and only if , where  is a column matrix that each entry is the inverse of similar entry of  and  is  matrix with all entries in  ,  is the transpose of  and . In this paper, we clarify some basic properties of the new graph and assign the structure of  when  is complete graph , complete bipartite graph  and complete

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (3)
Scopus Crossref