Preferred Language
Articles
/
jbcd-130
Effect of post-pressing times on adaptation of maxillary heat cured acrylic denture base at posterior palatal seal area

Background: The purpose of this study was to verify the influence of post- pressing time of acrylic resin (immediate, 6, 12 and 24 hour) on the dimensional accuracy of denture base whish is a critical factor in the retention and stability of the complete denture that may occur during polymerization shrinkage. Materials and Methods: Forty maxillary stone casts were poured in plastic mold (Columbia Dentoform corp. NEW YORK, type III dental stone (Geastone, Zeus Sri Loc.Tamburine Roccastrada, GR, Italy). The stone casts were randomly assigned into 4 groups of 10 specimens each according to the post-pressing times into (immediate, 6, 12 and 24 h.). Heat cure acrylic resin denture base was constructed according to the previously mentioned pressing time, the resin base-stone cast sets were transversally sectioned with a manual saw device at the distal aspect of the molar area, anterior to the posterior palatal seal area. The gap between the resin base and stone cast was measured at five points in the right (point B) and left (point D) ridge crests, at the midline (point C), and at the right (point A) and left (point E) marginal limits (A), using a Leitz linear optical comparator microscope with a travelling stage capable of measuring 0.001 mm. Each measurement was repeated three times and the average was used as the linear gap distance for that point. The data were submitted to ANOVA. Result: there was statistically significant difference between the pressing time in which the mean values of gap space in point E for 24h shows lowest value then point A, point B, and point D than the other post pressing time. The mean value in point C shows highest values which mean the greater gap space in palatal area.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Nov 19 2024
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of addition ZrO2-Al2O3 nanoparticles mixture on some properties and denture base adaptation of heat cured acrylic resin denture base material

Background: The PMMA polymer denture base materials are low mechanical properties, adaptation of the denture base to underlying tissue is important for retention and stability of denture. The aim of the study was toevaluate the effect of mixtureZrO2-Al2O3 nanoparticles on impact strength, transverse strength, hardness, roughness, denture base adaptation of heat cured acrylic resin denture base material. Materials and methods: One hundred (100) specimens were prepared, the specimens were divided into five groups (20 specimens to each) according to the test type, each group was subdivided in to two subgroups (control and experimental) each subgroup consist of 10 specimens, the experimental group included mixture of 2% (ZrO2-Al2O3ratio2:1) b

... Show More
View Publication Preview PDF
Publication Date
Tue Nov 19 2024
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of plasma treatment of acrylic denture teeth and thermocycling on the bonding strength to heat cured acrylic denture base material

Background: Acrylic resin polymer s used in prosthodontic treatment as a denture base material for several decades. Separation and debonding of artificial teeth from denture bases present a laboratory and clinical problem affect patient and dentist. The aim of this study is to evaluate the effect of oxygen plasma and argon plasma treatment of acrylic teeth and thermocycling on bonding strength to hot cured acrylic resin denture base material. Materials and Methods: Sixty denture teeth (right maxillary central incisor) are selected. The denture teeth are waxed onto the beveled surface of rectangular wax block according to Japanese standard for artificial teeth. The control group consisted of 20 denture teeth specimen without any treatment.

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of modified nanohydroxyapatite fillers addition on some properties of heat cured acrylic denture base materials

Background: Poly (methylmethacrylate) is not ideal in every aspect and has disadvantages such as insufficient surface hardness, increase water sorption and poor impact resistance and the latter being the primary cause of fracture of denture base resins. The aim of this study was to evaluate the effect of addition of silanized nano- hydroxyapatite (HA) on some properties of heat cured acrylic denture base material. Materials and methods: HA nano particles were first silanized with MPS (tri methacryloxypropyletrimethoxy silane coupling agent) then ultrasonicated with methylmethacrylate (monomer) to disperse agglomerated nano particles and mixed with polymer. 2% by wt of HA nano particles was selected as the best concentration that add

... Show More
Crossref (4)
Crossref
View Publication Preview PDF
Publication Date
Fri Jun 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of phosphate ester addition on transverse strength and hardness of heat cured acrylic denture base material

Background: acrylic resin denture base consider a common denture base material for its acceptable cost, aesthetic and easy processing but still has disadvantages including easy of fracture and low impact strength. Material and method: The experimental group was prepared by addition of 15% phosphoric acid 2-hydroxyethyl methacrylate ester (PA2HEME) with polymethyl methacrylate monomer; the experimental groups was compared with the control one. The specimens were prepared according to ADA specification No. 12 with dimension 65 mm x 10 mm x2.5 mm (length x width x thickness respectively). The prepared specimens were tested by three-point flexural strength utilizing Instron Universal Testing Machine (WDW, Layree Technology Co.), Shore D hard

... Show More
Crossref
View Publication Preview PDF
Publication Date
Tue Nov 19 2024
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of tissue displacement in posterior palatal seal area with different impression techniques with varying palatal forms

Background: This study was designed to measure the displacement pattern of posterior palatal seal (pps) area in different forms of the palate and with different impression techniques. Materials and method: This study was used to measure the displacement pattern of (pps)in different palatal shapes by using different impression materials Korrecta wax No.4,Green compound and design of House for pps for each palatal forms by using a 3D Scanner of CAD/CAM and measuring the distance between 2 points in pps area by using Caural Threw. Result: The results show highly significant differences between these techniques and the control group (impression with light body) Conclusion: The physiological impression technique of pps with Korecta wax no.4

... Show More
View Publication Preview PDF
Publication Date
Tue Nov 19 2024
Journal Name
Journal Of Baghdad College Of Dentistry
Teeth Displacement and Palatal Adaptation of Autoclave Cured acrylic resin with Various Palates and Investments.

Background: The denture base inaccuracies during processing negatively influence the retention and stability of finished complete denture. The aims of this study were to evaluate teeth movement and palatal adaptation of autoclave cured denture bases and their relationship with palatal depths and investments. Materials and methods: A nightly maxillary complete dentures prepared, processed and organized to be tested as follows: 1. Processing methods: water bath and autoclave with both fast and slow cycles. 2. Palatal depth: shallow, medium and deep. 3. Investing medium: stone and silicone. For every finished denture, two measurements were done: first: teeth movement by attaching metallic reference screws on the right and left centrals, first

... Show More
Crossref (1)
Crossref
View Publication Preview PDF
Publication Date
Sun Dec 09 2018
Journal Name
Baghdad Science Journal
Enhancement of the Tensile and the Compression Properties for Heat- Cured Acrylic Resin Denture Base Materials

This work aims to investigate the tensile and compression strengths of heat- cured acrylic resin denture base material by adding styrene-butadiene (S- B) to polymethyl methacrylate (PMMA). The most well- known issue in prosthodontic practice is fracture of a denture base. All samples were a blend of (90%, 80%) PMMA and (10%, 20%) S- B powder melted in Oxolane (Tetra hydro furan). These samples were chopped down into specimens of dimensions 100x10x2.5mm to carry out the requirements of tensile tests. The compression strength test specimens were shaped into a cylinder with dimensions of 12.7mm in diameter and 20mm in length. The experimental results show a significant increase in both tensile and compression strengths when compared to cont

... Show More
Scopus (6)
Crossref (1)
Scopus Clarivate Crossref
View Publication Preview PDF
Publication Date
Tue Nov 19 2024
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of the addition of silanized Nano titania fillers on some physical and mechanical properties of heat cured acrylic denture base materials

Background: Polymethyl methacrylate (PMMA) is the most commonly used material in denture fabrication. The material is far from ideal in fulfilling the mechanical requirement. The purpose of this study was to evaluate the effect of addition of 3% wt of treated (silanized) Titanium oxide Nano filler on some physical and mechanical properties of heat cured acrylic denture base material. Materials and methods: 100 specimens were constructed, 50 specimens were prepared from heat cure PMMA without additives (control) and 50 specimens were prepared from heat cure PMMA with the addition of TiO2 Nano fillers. Each group was divided into 5 sub groups according to the test performed which was mixed by probe ultra-sonication machine. Results: A highly

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 01 2024
Journal Name
Dental Hypotheses
Effect of Surface Treatments with Plasma and Chemical Bond on Shear Bond Strength of Acrylic Denture Teeth to Flexible and Heat-Cured Denture Base Material: An In Vitro Study

Introduction: We aimed to evaluate the shear bond strength of acrylic denture teeth to flexible and heat-cured denture base material after surface treatments with argon plasma, chemical bonding agent (PALFIQUE universal), and combination. Methods: A total of 80 incisor acrylic denture teeth were treated with a argonplasma, chemical bond (PALFIQUE universal bond), and a combination with 10 samples for each group. The neck (gingival portion) of teeth was cut at a 45° angle, and the teeth were attached to heat-cured acrylic resin and flexible denture base material. All the specimens were stored in artificial saliva for 7 days in an incubator (37 °C). A shear

... Show More
Scopus Clarivate Crossref
View Publication
Publication Date
Mon Mar 13 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of The CO2 Laser as Surface Treatment on The Bond Strength of Heat Cured Soft Liner to The High Impact Acrylic Denture Base Material

ABSRTACT Background: Soft liner material is become important in dental prosthetic treatment. They are applied to the surface of the dentures to achieve more equal force distribution , reduce localized pressure and improve denture retention by engaging undercut . So the aim of the study is to evaluate the effect of different surface treatment by air-abrasion AL2O3 and laser treatment with CO2 laser on improving the shear bond strength of the denture liner to acrylic denture base material . Materials and methods: the 30 specimens of heat cured acrylic denture base material (high Impact acrylic )and heat cured soft liner (Vertex ,Nether Lands )were prepared for this study .They were designed and divided according to type of the s

... Show More
Crossref (5)
Crossref
View Publication Preview PDF