Preferred Language
Articles
/
jbcd-1136
An Evaluation of Gutta-Percha Penetration Depth into Simulated Lateral Canals by Using Three Different Obturation Techniques (A Comparative Study)
...Show More Authors

Background:sThe aims of this study were to evaluate and compare the ability of three different techniques to obdurate simulated lateral canals, evaluate the effect of the main canal curvature on obturation of lateral canals and compare the gutta-percha penetration between coronal and apical lateral canals. Materials and methods: Resin blocks with 30 straight and 30 curved were used in this study. Each canal has two parallel lateral canals. The main canal has 0.3 mm apical diameter and 0.04 taper. The canals were divided into six groups according to canal curvature and obturation techniques used (n=10): Groups C1 and C2: straight and curved canals obturated with continuous wave technique using E&Q masterTM system. Groups O1 and O2: straight and curved canals obturated with Obtura II. Groups T1 and T2: straight and curved canals obturated with Thermafil obturators. Soapy water was used to simulate sealer in all obturations performed. The depth of gutta-percha penetration into lateral canals was measured using computerized stereomicroscope. Results: There were very highly significant differences between the obturation techniques at each lateral canal level in both straight and curved canals. Continuous wave using E&Q masterTM system exhibited the greatest gutta-percha penetration into lateral canals with very highly significant difference from both other techniques at majority of lateral canals. There was non- significant difference between Thermafil and Obtura II except at coronal lateral canal of straight main canals where the difference was very highly significant. The gutta-percha depth was greater in coronal than apical lateral canals in all groups of both straight and curved canals, and gutta-percha depth was greater in straight than in curved canals within each obturation technique. Conclusion: This study showed that all the three obturation techniques used were able to obturate simulated lateral canals with the continuous wave technique being the best. Gutta-percha depth was less in the apical than the coronal lateral canals. Canal curvature can influence the gutta-percha depth.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Dec 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Performance Evaluation of Three Phase Spray Direct Contact Heat Exchanger
...Show More Authors

 

The present investigation deals with experimental study of three-phase direct-contact heat exchanger, for water-Freon R11 system, where water is the continuous phase (liquid) and Freon R11 (liquid-gas) is the dispersed phase. The test section consisted of a cylindrical Perspex column with inner diameter 8cm and 1.2m long, in which, water was to be confined. Liquid Freon R11 drops were injected into the hot water filled column, through a special design of distributors at the bottom of the column. The liquid Freon R11 drops rose on their way up and evaporated into two-phase bubbles at atmospheric pressure. The study was devoted to express the effect of process variables such as c

... Show More
View Publication Preview PDF
Publication Date
Wed Aug 16 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Study the improvement of thermo - mechanical properties for polyester adhesive by using different fibers (glass, kevelar, and carbon).
...Show More Authors

The   mechanical    properties   of   fiber-reinforced-polymer   (FRP)

composites are dependent on the type amount, and orientation of fiber that is selected for a particular service. There are many commercially available reinforcement forms to meet the design requirements of the user. The ability of failure in the fiber architecture allows for optimized performance of a product that saves both weight and cost ( 12).

A modem technology is adopted to produce fibers (glass, kevelar,

and carbon) reinforced composite by using unsaturated polyester, where different volume fraction  of these fibers are used  (0, 0.2, 0.4, 0.6, 0.8,  I)

reinfor

... Show More
View Publication Preview PDF
Publication Date
Thu Mar 01 2007
Journal Name
Al-khwarizmi Engineering Journal
An experimental comparative study between polypropylene and laminated lower limb prosthetic socket
...Show More Authors

Most researchers concentrate their studies on the design, stress and pressure distributions of the prosthetic socket. A little attention is considered for the stiffness of the various materials of the prosthetic sockets. Prosthetic laminated sockets in Iraq are costly to be manufactured while polypropylene socket is relatively cheap in comparing with the laminates.

Experimental study is conducted to compare the stiffness of five prosthetic sockets made of different materials. Compression, three point flexural and tensile tests are implemented by the Testometric machine. The laminate sockets give better results in compression than polypropylene. Polypropylene gives good results in bending compared with the laminate sockets. When t

... Show More
View Publication Preview PDF
Publication Date
Wed Feb 01 2023
Journal Name
Chemical Engineering Research And Design
Nickel removal from simulated wastewater using a novel bio-electrochemical cell with packed bed rotating cylinder cathode
...Show More Authors

View Publication
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Wed Nov 07 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Evaluation of the Hardness of Cold Cured Acrylic Resin Material by Processing at Different Temperature
...Show More Authors

Objective(s): This study aims to evaluate the hardness of two commercially available cold cured acrylic resin material
(Vertex and PAN) when polymerized at different temperature in comparison to those polymerized by conventional
methods in air at 23C ± 5C.
Methodology: Eighty specimens, forty from cold cured acrylic (Vertex Type) and forty from cold cured acrylic (PAN
type) were prepared, flasking and packing procedure were done according to manufacturer direction and divided
according to processing as follow: 20 specimens (10 from Vertex type and 10 from PAN type) were processed in air for
two hours at 23C ± 5C under press (bench curing) as a control, and 60 specimens (30 from Vertex type and 30 from
PAN type) wer

... Show More
View Publication Preview PDF
Publication Date
Wed Jul 01 2020
Journal Name
Journal Of Engineering
Using Adaptive Neuro Fuzzy Inference System to Predict Rate of Penetration from Dynamic Elastic Properties
...Show More Authors

Rate of penetration plays a vital role in field development process because the drilling operation is expensive and include the cost of equipment and materials used during the penetration of rock and efforts of the crew in order to complete the well without major problems. It’s important to finish the well as soon as possible to reduce the expenditures. So, knowing the rate of penetration in the area that is going to be drilled will help in speculation of the cost and that will lead to optimize drilling outgoings. In this research, an intelligent model was built using artificial intelligence to achieve this goal.  The model was built using adaptive neuro fuzzy inference system to predict the rate of penetration in

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Feb 01 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
How geometric reverse engineering techniques can conserve our heritage; a case study in Iraq using 3D laser scanning
...Show More Authors
Abstract<p>Laser scanning has become a popular technique for the acquisition of digital models in the field of cultural heritage conservation and restoration nowadays. Many archaeological sites were lost, damaged, or faded, rather than being passed on to future generations due to many natural or human risks. It is still a challenge to accurately produce the digital and physical model of the missing regions or parts of our cultural heritage objects and restore damaged artefacts. The typical manual restoration can become a tedious and error-prone process; also can cause secondary damage to the relics. Therefore, in this paper, the automatic digital application process of 3D laser modelling of arte</p> ... Show More
View Publication
Scopus (6)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2014
Journal Name
Tikrit Journal Of Social Studies And Humanities
A Cultural Window into obituaries of Iraqi Newspapers
...Show More Authors

Publication Date
Wed Jan 08 2025
Journal Name
Al–bahith Al–a'alami
Organizational reputation: A descriptive study of concept development and measurement techniques
...Show More Authors

The study aimed to monitor the concept of reputation in the previous literature, its relationship to mental image and identity, and to reveal recent trends in its measurement Techniques.

    The study relied on a descriptive approach using library survey and comparative analysis, and the study reached following conclusions:

     Despite the beginning of the first signs of reputation In the fifties of the last century, however, Defining and standardizing the concept with clear and specific dimensions began in the 1990s and the beginning of the third millennium. The concept of reputation refers to the stakeholders’ overall evaluation of organizations, which reflects their perceptions of

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Jul 17 2019
Journal Name
Aip Conference Proceedings
The correction of the line profiles for x-ray diffraction peaks by using three analysis methods
...Show More Authors

In this study used three methods such as Williamson-hall, size-strain Plot, and Halder-Wagner to analysis x-ray diffraction lines to determine the crystallite size and the lattice strain of the nickel oxide nanoparticles and then compare the results of these methods with two other methods. The results were calculated for each of these methods to the crystallite size are (0.42554) nm, (1.04462) nm, and (3.60880) nm, and lattice strain are (0.56603), (1.11978), and (0.64606) respectively were compared with the result of Scherrer method (0.29598) nm,(0.34245),and the Modified Scherrer (0.97497). The difference in calculated results Observed for each of these methods in this study.

View Publication
Scopus (10)
Crossref (10)
Scopus Clarivate Crossref