Preferred Language
Articles
/
jbcd-1136
An Evaluation of Gutta-Percha Penetration Depth into Simulated Lateral Canals by Using Three Different Obturation Techniques (A Comparative Study)
...Show More Authors

Background:sThe aims of this study were to evaluate and compare the ability of three different techniques to obdurate simulated lateral canals, evaluate the effect of the main canal curvature on obturation of lateral canals and compare the gutta-percha penetration between coronal and apical lateral canals. Materials and methods: Resin blocks with 30 straight and 30 curved were used in this study. Each canal has two parallel lateral canals. The main canal has 0.3 mm apical diameter and 0.04 taper. The canals were divided into six groups according to canal curvature and obturation techniques used (n=10): Groups C1 and C2: straight and curved canals obturated with continuous wave technique using E&Q masterTM system. Groups O1 and O2: straight and curved canals obturated with Obtura II. Groups T1 and T2: straight and curved canals obturated with Thermafil obturators. Soapy water was used to simulate sealer in all obturations performed. The depth of gutta-percha penetration into lateral canals was measured using computerized stereomicroscope. Results: There were very highly significant differences between the obturation techniques at each lateral canal level in both straight and curved canals. Continuous wave using E&Q masterTM system exhibited the greatest gutta-percha penetration into lateral canals with very highly significant difference from both other techniques at majority of lateral canals. There was non- significant difference between Thermafil and Obtura II except at coronal lateral canal of straight main canals where the difference was very highly significant. The gutta-percha depth was greater in coronal than apical lateral canals in all groups of both straight and curved canals, and gutta-percha depth was greater in straight than in curved canals within each obturation technique. Conclusion: This study showed that all the three obturation techniques used were able to obturate simulated lateral canals with the continuous wave technique being the best. Gutta-percha depth was less in the apical than the coronal lateral canals. Canal curvature can influence the gutta-percha depth.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Mar 31 2018
Journal Name
Journal Of Engineering
Effecting of pH Parameter on Simulated Wastewater Treatment Using Electrocoagulation Method
...Show More Authors

The aim of the present research is to investigate the effecting of pH parameter on the feasibility of lead removal from simulated wastewater using an electrochemical system. Electrocoagulation method is one of electrochemical technology which is used widely to treat industrial wastewater. Parameters affecting this operation, such as initial metal concentration, applied current, stirrer speed, and contact time of electroprocessing were taken as 155ppm, 1.5 Ampere, 150 rpm, 60 minutes respectively. While pH of the simulated wastewater was in the range of  2 to 12 in the experiments. It was found from the results that pH is an important parameter affecting lead removal operation. The best value of pH parameter is appro

... Show More
View Publication Preview PDF
Scopus (19)
Crossref (15)
Scopus Crossref
Publication Date
Mon Mar 13 2017
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Artificial Accelerated Aging on The Color of Ceramic Veneers Cemented With Different Resin Cements (A Comparative In Vitro Study)
...Show More Authors

ABSTRACT Background: Color changes that are detectable to human eye can affect the esthetic appearance of ceramic veneers. The purpose of this study was to evaluate and compare the effect of artificial accelerated aging on the color of ceramic veneers cemented with different resin cements. Materials and Methods: Sixty discs were prepared with 0.5 mm thickness, 30 discs made from IPS e.max press (Ivoclar Vivadent) and 30 discs were made from VITA Enamic (VITA Zahnfabrik). The discs were cemented with three resin cements: Variolink Veneer MV 0 shade (Ivoclar Vivadent), Rely X veneer Translucent shade (3M ESPE) and NX3 Nexus Clear shade (Kerr Corporation) with 0.1 mm thickness. The spectrophotometer Easyshade Advance was used to measure the co

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Tue Dec 15 2020
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of ageing media on shear bond strength of metal orthodontic brackets bonded with different adhesive systems (A comparative in-vitro study)
...Show More Authors

Background: The aim of this study was to evaluate the shear bond strength (SBS) and adhesive remnant index (ARI) of different orthodontic adhesive systems after exposure to aging media (water storage and acid challenge). Materials and methods: Eighty human upper premolar teeth were extracted for orthodontic purposes and randomly divided into two groups (40 teeth each): the first group in which the bonded teeth were stored in distilled water for 30 days at 37°C, and the second group in which the bonded teeth were subjected to acid challenge. Each group was further subdivided into four subgroups (10 teeth each) according to the type of adhesive system that would be bonded to metal brackets: either non-fluoride releasing adhesive (NFRA),

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (3)
Scopus Crossref
Publication Date
Fri Aug 12 2022
Journal Name
Journal Of Research In Medical And Dental Science
Effects of Ozonated Water on Micro Leakage between Enamel and Fissure Sealants Prepared by Different Etching Technique (An in vitro Study)
...Show More Authors

Effects of Ozonated Water on Micro Leakage between Enamel and Fissure Sealants Prepared by Different Etching Technique (An in vitro Study), Baraa M Jabar*, Muna S Khalaf

View Publication Preview PDF
Publication Date
Fri Sep 01 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Assessing the Radiopacity of Three Resin Composite Materials Using a Digital Radiography Technique
...Show More Authors

Background: Radiopacity is one of the prerequisites for dental materials, especially for composite restorations. It's essential for easy detection of secondary dental caries as well as observation of the radiographic interface between the materials and tooth structure. The aim of this study to assess the difference in radiopacity of different resin composites using a digital x-ray system. Materials and methods: Ten specimens (6mm diameter and 1mm thickness) of three types of composite resins (Evetric, Estelite Sigma Quick,and G-aenial) were fabricated using Teflon mold. The radiopacity was assessed using dental radiography equipment in combination with a phosphor plate digital system and a grey scale value aluminum step wedge with thickness

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Sep 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Assessing The Radiopacity of Three Resin Composite Materials Using a Digital Radiography Technique
...Show More Authors

Background: Radiopacity is one of the prerequisites for dental materials, especially for composite restorations. It's essential for easy detection of secondary dental caries as well as observation of the radiographic interface between the materials and tooth structure. The aim of this study to assess the difference in radiopacity of different resin composites using a digital x-ray system. Materials and methods: Ten specimens (6mm diameter and 1mm thickness) of three types of composite resins (Evetric, Estelite Sigma Quick,and G-aenial) were fabricated using Teflon mold. The radiopacity was assessed using dental radiography equipment in combination with a phosphor plate digital system and a grey scale value aluminum step wedge with thickness

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Mar 01 2017
Journal Name
Journal Of Craniofacial Surgery
Lateral Ridge Splitting (Expansion) With Immediate Placement of Endosseous Dental Implant Using Piezoelectric Device
...Show More Authors

View Publication
Crossref (15)
Crossref
Publication Date
Sun Jul 02 2023
Journal Name
Iraqi Journal Of Science
Seismic Structural –Stratigraphic Study of Dhufria Area (Mid -Iraq) Using (3D) Techniques
...Show More Authors

This study deals with the seismic reflection interpretation of lower Cretaceous Formations in Dhufria area, including structural and stratigraphic techniques. In the interpretation process, the 3-D seismic data volume and well logs have been used. Based on well logs and synthetic traces two horizons were identified and picked which are the top and bottom of Zubair Formation. These horizons were followed over all the area in order to obtain structural setting as well as studying Kirkuk group Formation of Tertiary age which represents highstand progradational seismic facies.

View Publication Preview PDF
Publication Date
Fri Jun 03 2016
Journal Name
Iraqi Medical Journal
EVALUATION OF PATIENTS WITH CARPAL TUNNEL SYNDROME TREATED BY MINIMAL PALMAR INCISION (A PRELIMINARY STUDY)
...Show More Authors

Background : Carpal tunnel syndrome (CTS) is the most common entrapment neuropathy of upper extremities and Open carpal tunnel release is the most frequent surgical procedure and the gold standard for cases that do not respond to conservative treatment. Aims :This study is used to evaluate the functional outcome of limited palmar mini-incision of carpal tunnel release. This study aims to determine the safety and symptomatic and functional efficacy of median nerve decompression with limited incision in carpal tunnel syndrome surgery. Patients and methods:Carpal tunnel release with a 1.5-2 cm limited palmar incision was performed on 20 patients. Patients were evaluated initially at one month after treatment according to symptom severity

... Show More
View Publication Preview PDF
Publication Date
Sun May 28 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Performance Evaluation of three Indian Wheat Varieties Under Iraqi Environment
...Show More Authors

 The performance of the Indian wheat varieties (PBW34, PBW343 and WH542) was compared with the local varieties (Tamose – 2 and Abu Ghareeb).      The experiment was conducted during two seasons first 2000-2001 and second 2001-2002 at AL- Twaitha experimental station , middle of Iraq.         The results showed that (Tamose – 2) exceeded the other varieties in plant height and heading date in the two seasons, while WH542 gave the lowest plant height.  PBW34 variety showed a significant increase in 1000 grain weight followed by PBW343 in the second season. Moreover, PBW34 and PBW343 gave the highest average of 50 spike weight in the second season.&nbsp

... Show More
View Publication Preview PDF