Preferred Language
Articles
/
iqjmc-476
The Monosynaptic H-reflex excitability in post-Stroke patients.
...Show More Authors

Backgrond: One of the major causes of impaired movements post-stroke is the abnormal phasing of paralytic muscles. Many studies suggested that inappropriate muscle phasing may be associated with enhanced transmission in the monosynaptic Group Ia afferent pathway in the affected limb of post-stroke patients and Group Ia reflexes are abnormally elevated and fail to decrease in amplitude during locomotion.

Objectives: This study was conducted to identify the changes in the Soleus muscle H-reflex excitability at rest in the affected lower limb of post-stroke patients as compared to the contra lateral side and of normal controls.

Patients and methods: The excitability of the monosynaptic Hoffman’s (H-reflex) pathway was tested in the affected side of 48 chronic stroke patients during rest and waking by calculation of the H-reflex wave amplitude and the ratio of maximal H /maximal M response amplitudes and compared to the contra lateral side as well as with that of 32 normal subjects of the matching age and sex. The H-reflex was evoked in the soleus muscle after stimulation of the tibial nerve at the popliteal fossa.

Results: The mean H-reflex wave amplitude (Ha) values are found to have statistical significant difference between the affected and non affected sides as well as between the affected side and the control group (P <0.05) while the mean maximum M-response amplitude (Ma) showed no statistical differences between all groups (P>0.05). However, the ratio of mean amplitude of the maximum H-wave to that of the maximum M-response (Ha/Ma) was significantly higher in the affected side as compared to the contra lateral and control group (P <0.05).

Conclusion: Our results showed that the Ha/Ma ratio does provide a helpful electrophysiological tool for the assessment of stroke patients by identifying motorneuron hyperexcitability, where in most cases of stroke there is a reflexologic characteristic differentiating them from normal, therefore, the Ha/Ma ratio is an interesting test that can be used to interpret recovery patterns and longitudinal effects of therapeutic interventions and follow up post-stroke.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Dec 22 2024
Journal Name
Journal Of Baghdad College Of Dentistry
Comparison of fit among different types of post restorations luted with conventional cement
...Show More Authors

Background: with the advent of new postmaterial in dentistry, it has become important to measure fitness of post restoration along the horizontal plane of the root space.This study aimed to measure and compare, the cement film thickness of conventional zinc phosphate cement in micrometer between the post and root dentin along horizontal plane at different post space regions (coronal, middle and apical) of four types of posts, by using stereomicroscopy. Material and methods: Thirty-two extracted human maxillary canines, mandibular canines and maxillary central incisors (n=32) were instrumented with ProTaper system files (hand use) and obturated with gutta-percha for ProTaper and AH26® root canal sealer. After 24hrs of incubation at 37ºC, p

... Show More
View Publication Preview PDF
Publication Date
Wed Oct 09 2019
Journal Name
Engineering, Technology &amp; Applied Science Research
Numerical Analysis of Segmental Post Tensioned Concrete Beams Exposed to High Fire Temperature
...Show More Authors

The main objective of this study is to characterize the main factors which may affect the behavior of segmental prestressed concrete beams comprised of multi segments. The 3-D finite element program ABAQUS was utilized. The experimental work was conducted on twelve simply supported segmental prestressed concrete beams divided into three groups depending on the precast segments number. They all had an identical total length of 3150mm, but each had different segment numbers (9, 7, and 5 segments), in other words, different segment lengths. To simulate the genuine fire disasters, nine beams were exposed to high-temperature flame for one hour, the selected temperatures were 300°C (572°F), 500°C (932°F) and 700°C (1292°F) as recomm

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sat Dec 11 2021
Journal Name
Engineering, Technology &amp; Applied Science Research
Post-Fire Behavior of Non-Prismatic Beams with Multiple Rectangular Openings Monotonically Loaded
...Show More Authors

The main objective of this paper is to study the behavior of Non-Prismatic Reinforced Concrete (NPRC) beams with and without rectangular openings either when exposed to fire or not. The experimental program involves casting and testing 9 NPRC beams divided into 3 main groups. These groups were categorized according to heating temperature (ambient temperature, 400°C, and 700°C), with each group containing 3 NPRC beams (solid beams and beams with 6 and 8 trapezoidal openings). For beams with similar geometry, increasing the burning temperature results in their deterioration as reflected in their increasing mid-span deflection throughout the fire exposure period and their residual deflection after cooling. Meanwhile, the existing ope

... Show More
Crossref (10)
Crossref
Publication Date
Sat Dec 11 2021
Journal Name
Engineering, Technology &amp; Applied Science Research
Post-Fire Behavior of Non-Prismatic Beams with Multiple Rectangular Openings Monotonically Loaded
...Show More Authors

The main objective of this paper is to study the behavior of Non-Prismatic Reinforced Concrete (NPRC) beams with and without rectangular openings either when exposed to fire or not. The experimental program involves casting and testing 9 NPRC beams divided into 3 main groups. These groups were categorized according to heating temperature (ambient temperature, 400°C, and 700°C), with each group containing 3 NPRC beams (solid beams and beams with 6 and 8 trapezoidal openings). For beams with similar geometry, increasing the burning temperature results in their deterioration as reflected in their increasing mid-span deflection throughout the fire exposure period and their residual deflection after cooling. Meanwhile, the existing ope

... Show More
View Publication Preview PDF
Scopus (10)
Crossref (10)
Scopus Crossref
Publication Date
Fri Oct 01 2010
Journal Name
Iraqi Journal Of Physics
Investigation of plasma characteristics of center region of post cylindrical magnetron sputtering device
...Show More Authors

A d.c. magnetron sputtering system was designed and fabricated. The chamber of this system is consisted from two copper coaxial cylinders. The inner one used as the cathode and the outer one used as anode with magnetic coil located on the outer cylinder (anode). The axial behavior of the magnetic field strength along the cathode surface for various coil current (from 2A to 14A) are shown. The results of this work are investigated by three cylindrical Langmuir probes that have different diameters that are 2.2mm, 1mm, and 0.45mm. The results of these probes show that, there are two Maxwellian electron groups appear in the central region. As well as, the density of electron and ion decreases with increases of magnetic field strengths.

View Publication Preview PDF
Publication Date
Thu Oct 01 2015
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Delayed Recovery of Contrast Induced Kidney Injury Post Angiography: Rate and Risk Factors
...Show More Authors

Background: Exposure to Contrast media is the third leading cause of hospital acquired acute kidney injury. It follows a predictable time of onset and a less predictable scenario in recovery. This is related to certain factors, but at the end there will be asubstantial association with increased mortality, morbidity, and length of hospitalization.
Objectives: To define the Incidence of persistent contrast induced renal impairment a month after angiography and to define the risk factors for such persistence
Patients and Methods: One hundred and one patients (101) were enrolled in this study. All were referred to the Iraqi Center for Heart Diseases in Baghdad/ Iraq for coronary and/or peripheral vascular angi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of Engineering
Serviceability of Post-fire RC Rafters with Openings of Different Sizes and Shapes
...Show More Authors

This study deals with the serviceability of reinforced concrete solid and perforated rafters with openings of different shapes and sizes based on an experimental study that includes 12 post-fire non-prismatic reinforced concrete beams (solid and perforated). Three groups were formed based on heating temperature (room temperature, 400 °C, and 700 °C), each group consisting of four rafters (solid, rafters with 6 and 8 trapezoidal openings, and rafter with eight circular openings) under static loading. A developed unified calculation technique for deflection and crack widths under static loading at the service stage has been provided, which comprises non-prismatic beams with or without opening exposed to flexure concentra

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Mon Jul 01 2019
Journal Name
Iop Conference Series: Materials Science And Engineering
Corrosion protection of pure titanium implant by electrochemical deposition of hydroxyapatite post-anodizing
...Show More Authors

In this study, a Hydroxyapatite (HA) coating was prepared on a titanium implant by an electrochemical deposition process. The titanium pre-treatment by anodizing in 1.65 mol/L sulfuric acid with (10V) at room temperature. The deposition was all conducted at a constant voltage of 6.0 V, for 1 h at room temperature. The coatings thus prepared were characterized with Fourier transform infrared spectroscopy (FTIR) and thickness of the coated layer.The electrochemical deposition of HA occurred on the titanium as a cathode. Coated titanium by HA after anodizing revealed a good corrosion protection efficiency even at a temperature ranged (293-323) K in artificial saliva. Activation energy and pre-exponential factor (kinetic parameters) were calcul

... Show More
View Publication Preview PDF
Scopus (12)
Scopus
Publication Date
Mon Jul 30 2018
Journal Name
Civil Engineering Journal
Performance of Post-Fire Composite Prestressed Concrete Beam Topped with Reinforced Concrete Flange
...Show More Authors

The performance of composite prestressed concrete beam topped with reinforced concrete flange structures in fire depends upon several factors, including the change in properties of the two different materials due to fire exposure and temperature distribution within the composition of the composite members of the structure. The present experimental work included casting of 12 identical simply supported prestressed concrete beams grouped into 3 categories, depending on the strength of the top reinforced concrete deck slab (20, 30, and 40 MPa). They were connected together by using shear connector reinforcements. To simulate the real practical fire disasters, 3 composite prestressed concrete beams from each group were exposed to high t

... Show More
View Publication Preview PDF
Crossref (2)
Clarivate Crossref
Publication Date
Thu Jan 01 2015
Journal Name
Journal Of Plant Interactions
Photosynthetic and biochemical characterization of in vitro-derived African violet (<i>Saintpaulia ionantha</i>H. Wendl) plants to ex vitro conditions
...Show More Authors

View Publication
Scopus (18)
Crossref (18)
Scopus Clarivate Crossref