Preferred Language
Articles
/
ijs-865
Depth dose measurement in water phantom for two X-ray energies (6MeV and 10MeV) in comparison with actual planning
...Show More Authors

The purpose of this study is to measure doses delivered at different depths in water phantom at vertical position in comparison with the actual planning in order to verify the dose delivered to the tumor in addition to the measurement of the effect penumbra dose to assess the dose leaking to the healthy soft tissue.

     Percentage depth dose (PDD) values was measured at field sizes (5×5,10×10,15×15, and 20×20) cm2, and the depth dose was measured between (0-16) cm deep at 4cm intervals, for both energies 6 MeV and 10 MeV X-ray beam. Other readings were taken at different distances 1cm and 2cm outside of the actual beam in orthogonal directions at depth of 4 cm. These measurements were designed to measure the penumbra dose produced outside the central beam.

     Results show that the high similarity between water phantom and actual tissue for this reason water is taken as phantom for Quality Assurance (QA) and calculation the depth dose. The similar results may appear strange as the actual planning depth dose is taken in the chest wall where there is bone and soft tissue. The increase in the field size, increases the percentage of surface dose, this could be caused by an increase in the amount of scattering in the larger fields. There is almost no difference in depth dose between homogenous and non homogenous planning also similar to the water phantom. Because of higher photon energy 6MeV and 10MeV the bone has no influence in absorption from the soft tissue. A slight change in the depth dose with increase in the field size may be caused by the scattered radiation.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Oct 30 2022
Journal Name
Iraqi Journal Of Science
Measurement of Absorbed Dose in Water Using Co-60 gamma source Teletherapy Units According to IAEA Dosimetry Protocols
...Show More Authors

      Modern radiotherapy facilities like 3-Dimensional conformal radio therapy (3DCRT), Intensity Modulated Radiotherapy (IMRT), were recently suggested in Co-60 machine with Multi-leaf Collimator (MLC). In this study, two reference chambers NE-2571#1205 and NE2581#537 were used for absolute dose measurement in Equinox accelerator. A comparison of dose measurement by two different IAEA protocols TRS-277 and TRS-398 has been studied. Analyzing TRS-398, a common shaped empirical formula was developed for the four Co-60 units of four Medical Colleges in Bangladesh with fitting parameters. It was found that an average discrepancy in the determination of absorbed dose in water among the two different protocols TRS-277 and TRS-398 were 1

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Thu Apr 01 2021
Journal Name
Pakistan Journal Of Statistics
Estimation intensity radiation of chest X-ray (CXR) with application
...Show More Authors

In this research we assumed that the number of emissions by time (𝑡) of radiation particles is distributed poisson distribution with parameter (𝑡), where  < 0 is the intensity of radiation. We conclude that the time of the first emission is distributed exponentially with parameter 𝜃, while the time of the k-th emission (𝑘 = 2,3,4, … . . ) is gamma distributed with parameters (𝑘, 𝜃), we used a real data to show that the Bayes estimator 𝜃 ∗ for 𝜃 is more efficient than 𝜃̂, the maximum likelihood estimator for 𝜃 by using the derived variances of both estimators as a statistical indicator for efficiency

Preview PDF
Scopus
Publication Date
Sat Aug 01 2015
Journal Name
Euphrates Journal Of Agricultural Science
MEASURES OF SPECIFIC PRODUCTIVITY, ACTUAL TIME, APPEARANCE AND TILLAGE DEVIATION FOR TWO PLOWS MOSTLY USED IN IRAQ
...Show More Authors

Experiment was conducted in Baghdad, three factor were used in this research included Two types of Plows included moldboard and disk plows which represented the main plot, Three forward speeds of the tillage was the second factor included 1.85, 3.75 and 5.62 km / h which represented sup plot , and Three levels of Soil Moisture was third factor included 21, 18 and 14 % in all of Vertical and Lateral Plowing Deviation, Practical and specific productivity, actual time for plowing one donam and appearance (goodness) of Tillage represented by the number of clods > 10 cm in silt clay loam soil with depth 22 cm were studied. the experiment was used Split – split plot design under randomized complete block design with three replications and Le

... Show More
Publication Date
Wed Dec 01 2021
Journal Name
Journal Of Physics: Conference Series
Evaluation the Safety and Security Procedures used In X-ray Clinics in Al-Harthiya-Baghdad
...Show More Authors
Abstract<p>Radiation is a form of energy, its emitted either in the form of particles such as α-particles and β-particles (beta particles including the electron and the positron) or waves such as sunlight, X-rays and γ-rays. Radiation found everywhere around us and it comes from many different sources naturally or man-made sources. In this study a questionnaire was distributed to people working in the field of X-rays that used for a medical imaging (X-ray and CT-scan) to evaluate the extent of awareness and knowledge in estimate the damage of ionizing radiation as a result of wrong use. The questionnaire was distributed to medical clinics in Al-Harithiya in Baghdad, which it’s considered as</p> ... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Sun Feb 03 2019
Journal Name
Iraqi Journal Of Physics
Effect of indium content on X- ray diffraction and optical constants of InxSe1-x thin films
...Show More Authors

Alloys of InxSe1-x were prepared by quenching technique with
different In content (x=10, 20, 30, and 40). Thin films of these alloys
were prepared using thermal evaporation technique under vacuum of
10-5 mbar on glass, at room temperature R.T with different
thicknesses (t=300, 500 and 700 nm). The X–ray diffraction
measurement for bulk InxSe1-x showed that all alloys have
polycrystalline structures and the peaks for x=10 identical with Se,
while for x=20, 30 and 40 were identical with the Se and InSe
standard peaks. The diffraction patterns of InxSe1-x thin film show
that with low In content (x=10, and 20) samples have semi
crystalline structure, The increase of indium content to x=30
decreases degree o

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Wed Feb 01 2023
Journal Name
Indonesian Journal Of Electrical Engineering And Computer Science
Diagnose COVID-19 by using hybrid CNN-RNN for Chest X-ray
...Show More Authors

<p>Combating the COVID-19 epidemic has emerged as one of the most promising healthcare the world's challenges have ever seen. COVID-19 cases must be accurately and quickly diagnosed to receive proper medical treatment and limit the pandemic. Imaging approaches for chest radiography have been proven in order to be more successful in detecting coronavirus than the (RT-PCR) approach. Transfer knowledge is more suited to categorize patterns in medical pictures since the number of available medical images is limited. This paper illustrates a convolutional neural network (CNN) and recurrent neural network (RNN) hybrid architecture for the diagnosis of COVID-19 from chest X-rays. The deep transfer methods used were VGG19, DenseNet121

... Show More
View Publication
Scopus (12)
Crossref (2)
Scopus Crossref
Publication Date
Thu Dec 01 2022
Journal Name
Baghdad Science Journal
Diagnosing COVID-19 Infection in Chest X-Ray Images Using Neural Network
...Show More Authors

With its rapid spread, the coronavirus infection shocked the world and had a huge effect on billions of peoples' lives. The problem is to find a safe method to diagnose the infections with fewer casualties. It has been shown that X-Ray images are an important method for the identification, quantification, and monitoring of diseases. Deep learning algorithms can be utilized to help analyze potentially huge numbers of X-Ray examinations. This research conducted a retrospective multi-test analysis system to detect suspicious COVID-19 performance, and use of chest X-Ray features to assess the progress of the illness in each patient, resulting in a "corona score." where the results were satisfactory compared to the benchmarked techniques.  T

... Show More
View Publication Preview PDF
Scopus (4)
Scopus Clarivate Crossref
Publication Date
Tue Jan 08 2019
Journal Name
Iraqi Journal Of Physics
X- ray diffraction and dielectric properties of PbSe thin films
...Show More Authors

Lead selenide PbSe thin films of different thicknesses (300, 500, and 700 nm) were deposited under vacuum using thermal evaporation method on glass substrates. X-ray diffraction measurements showed that increasing of thickness lead to well crystallize the prepared samples, such that the crystallite size increases while the dislocation density decreases with thickness increasing. A.C conductivity, dielectric constants, and loss tangent are studied as function to thickness, frequency (10kHz-10MHz) and temperatures (293K-493K). The conductivity measurements confirm confirmed that hopping is the mechanism responsible for the conduction process. Increasing of thickness decreases the thermal activation energy estimated from Arhinus equation is

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Apr 19 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Measurement and Characterization of Natural Radioactive Contaminants and Industrial for the Sediments Diyala River Basin with Using Gamma-Ray Spectroscopy
...Show More Authors

    In this research, we have achieved the description of radionuclides that exist in the samples of Diyala river sediments as well as to measure the specific activities using gamma-ray spectroscopy. The eleven samples were collected among the length of Diyala River starting from Al- Rustumiya and finishing at the point where Diyala River meets Tigris which is in Baghdad.      Gamma-ray spectrometry system consists of high-purity germanium detector (HpGe) with 50% efficiency and resolution (2.2 keV) for the energy (1332 keV) was used for standard source 60Co.     Card spectrum analyzer connected to the PC type Pentium 4 was used to view the spectrum. And  rates of the speci

... Show More
View Publication Preview PDF
Publication Date
Sat Mar 01 2008
Journal Name
Iraqi Journal Of Physics
The Determination of Lower Limit Detection of X-Ray Fluorescence for Zinc Powder Suspended in Engine Oil
...Show More Authors

In this work Different weight of pure Zinc powder suspended particles in 4ml base engine Oil were used.
Intensity of Kα Line was measured for the suspended particles ,also for mixture which consist from Zinc particle blended with Engine base Oil. Calibration Curve was drawn between Ikα line Intensity and Zinc concentration at different operation condition. The Lower Limit detection (LLD) and Sensitivity (m) of Spectrometer were determined for different Zinc Concentration (Wt%). The results of LLD and m for Samples were analyzed at Operation Condition of 30KV,17mA is best from Samples were analyzed at Operation Condition of 25KV,15mA

View Publication Preview PDF