Depth dose measurement in water phantom for two X-ray energies (6MeV and 10MeV) in comparison with actual planning
...Show More Authors

The purpose of this study is to measure doses delivered at different depths in water phantom at vertical position in comparison with the actual planning in order to verify the dose delivered to the tumor in addition to the measurement of the effect penumbra dose to assess the dose leaking to the healthy soft tissue.

     Percentage depth dose (PDD) values was measured at field sizes (5×5,10×10,15×15, and 20×20) cm2, and the depth dose was measured between (0-16) cm deep at 4cm intervals, for both energies 6 MeV and 10 MeV X-ray beam. Other readings were taken at different distances 1cm and 2cm outside of the actual beam in orthogonal directions at depth of 4 cm. These measurements were designed to measure the penumbra dose produced outside the central beam.

     Results show that the high similarity between water phantom and actual tissue for this reason water is taken as phantom for Quality Assurance (QA) and calculation the depth dose. The similar results may appear strange as the actual planning depth dose is taken in the chest wall where there is bone and soft tissue. The increase in the field size, increases the percentage of surface dose, this could be caused by an increase in the amount of scattering in the larger fields. There is almost no difference in depth dose between homogenous and non homogenous planning also similar to the water phantom. Because of higher photon energy 6MeV and 10MeV the bone has no influence in absorption from the soft tissue. A slight change in the depth dose with increase in the field size may be caused by the scattered radiation.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Jul 20 2023
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Measurement of Radon Concentration in Drink and Well Water Samples for Selected Regions in Baghdad City
...Show More Authors

 The concentration of radon gas in the samples for drinking water and wells in the same place from selected homes in which wells were built in the Hay-al-Bayaa region of Baghdad was measured, by using a CR-39 nuclear track detector. It turns out that the maximum value of the concentration of radon in drinking water was 3.83 Bq/L, and the lowest was 2.30 Bq/L. As for the estimation of radon gas concentration in well water samples, the highest value was 5.6 Bq/L, while the lowest one was 3.1 Bq/L. In order to assess the committed effective dose received by the public due to the inhalation of radon gas. The highest value of the annual effective dose in drinking water was recorded in Al-Bayaa region, which is equal to 14.30 μSv/y, while th

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Aug 21 2022
Journal Name
International Journal Of Health Sciences
Effect of x- ray on the treatment of breast cancer combined with amygdalin and doxorubicin separately
...Show More Authors

Background: Radiation therapy has the ability to destroy healthy cells in addition to cancer cells in the area being treated. However, when radiation combines with doxorubicin, it becomes more effective on breast cancer treatment. Objective: This study aims to clarify the effect of X-ray from LINAC combined with amygdalin and doxorubicin on breast cancer treatment, and the possibility of using amygdalin with X-ray instead of doxorubicin for the breast cancer treatment. Method: Two cell lines were used in this study, the first one was MCF-7 cell line and second one was WRL- 68 normal cell line. These cells were preserved in liquid nitrogen, prepared, developed and tested in the (place). The effect of three x-ray doses combined with a

... Show More
View Publication
Crossref
Publication Date
Thu Sep 01 2022
Journal Name
Iraqi Journal Of Physics
X-Ray Emission Spectroscopy Analysis for Near-Asteroid Belt of Atmospheric of the Comets
...Show More Authors

         According to Chandra Survey Observatory Near-Asteroid Belt Comets, the solar wind's contact with the comet produces a variety of spectral characteristics. The study of X-ray spectra produced by charge exchange is presented here. The spectrum of a comet can reveal a lot about its composition. This study has concentrated on the elemental abundance in six different comets, including 17P/Holmes, C/1999T1, C/2013A1, 9p/Temple1, and 103p/Hartley2 (NEAT). Numerous aspects of the comet's dynamics allow it to behave in a unique manner as it gets closer to the Near-Asteroid Belt. These characteristics are being examined, and some studies are still ongoing. The computations allow us to observe, for instance, how the composition of

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 30 2013
Journal Name
Al-kindy College Medical Journal
Haemogloin Level, Blood Group, Chest X Ray Findings and Consanguinity in Thalassemic Children in AL Muthana Governorate
...Show More Authors

Background: Thalassemia is characterized by the decrease or absence of the synthesis of one or more globin chains of hemoglobin. Thalassemia is distributed worldwide and is characterized by; regular blood transfusion which is creating alloimmunization to erythrocyte antigens is one of the major complications of regular blood transfusions in thalassemia, particularly in patients who are chronically transfused.Objectives: The aims of this study are to understand the immune system profile as the triggering factor for thalassemia.Methods: Thirty patients aging between one year and four months and twenty two years, twenty two of them were boys and eight were girls. Twenty nine patients, their parents are relative except one and studied in the

... Show More
View Publication Preview PDF
Publication Date
Thu Apr 28 2022
Journal Name
Iraqi Journal Of Science
Two Techniques (Spectrophotometric and Turbidimetric) for Determination of Ciprofloxacin HCl in Pharmaceutical Drugs with Comparison between the Techniques
...Show More Authors

A new, effective, simple and inexpensive method was developed for determination the amounts of Ciprofloxacin HCl in solutions and in tablets by spectrophotometry and turbidity using sodium tungstate as reagent. Also, in this paper comparison between two techniques was conducted. The reaction between the Ciprofloxacin HCl and reagent in acidic media formed a yellowish white complex. Chemical and physical conditions have been investigated. The Linear range for spectroscopic and turbidimetric techniques were (0.05-1.25) and (0.05-3.0) mmol.L-1 with correlation coefficients (0.9956) and (0.9941) respectively. The limits of detection were 7×10-5 and 5×10-5 mol.L-1. The proposed method is good alternative for determination of Ciprofloxacin H

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 15 2022
Journal Name
Malaysian Journal Of Science
STUDY THE RELATIONSHIP BETWEEN BREMSSTRAHLUNG DOSE RATE AND THE ENERGY OF BETA RAY FOR DIFFERENT TYPES OF SHIELD
...Show More Authors

The dose rate for bremsstrahlung radiation from beta particles with energy (1.710) MeV and (2.28) MeV which comes from (32P and 90Y) beta source respectively have been calculated through six materials (polyethylene, wood, aluminum, iron, tungsten and lead) for first shielding material with thickness (x=1) mm which are putting between beta sources and second shield (polyethylene, aluminum and lead) with thickness (1, 2 &4) mm have been calculated. The distance between beta source and second shield is constant (D=1) cm. This dose rate was found by program called Rad Pro Calculator (version 3.26). The results of dose rate of beta particles were plotted as a function to the atomic number (Z) for first shield materials for each

... Show More
Preview PDF
Publication Date
Wed Jun 15 2022
Journal Name
Malaysian Journal Of Science
STUDY THE RELATIONSHIP BETWEEN BREMSSTRAHLUNG DOSE RATE AND THE ENERGY OF BETA RAY FOR DIFFERENT TYPES OF SHIELD
...Show More Authors

The dose rate for bremsstrahlung radiation from beta particles with energy (1.710) MeV and (2.28) MeV which comes from (32P and 90Y) beta source respectively have been calculated through six materials (polyethylene, wood, aluminum, iron, tungsten and lead) for first shielding material with thickness (x=1) mm which are putting between beta sources and second shield (polyethylene, aluminum and lead) with thickness (1, 2 &4) mm have been calculated. The distance between beta source and second shield is constant (D=1) cm. This dose rate was found by program called Rad Pro Calculator (version 3.26). The results of dose rate of beta particles were plotted as a function to the atomic number (Z) for first shield materials for each

... Show More
View Publication
Scopus (2)
Scopus Crossref
Publication Date
Tue Aug 01 2023
Journal Name
Iop Conference Series: Earth And Environmental Science
Assessment of X-Ray Effects on HF Radio Communications
...Show More Authors
Abstract<p>This study aims to determine the effect of x-ray radiation resulting from solar flares in high-frequency radio wave communications through the ionosphere and to study the radio blackout events that occur over Iraq, located within (38,28) latitude, and (38,49) longitude. Using X-ray data during strong X flares and radio wave absorption data across the D ionosphere for 10 years from 2012 to 2021. The study concluded that there were 43 events of x-flare, most of which were during years of high solar activity. All of these flares produced X-rays that caused a radio blackout, R3 and only 13 events affected Iraq.</p>
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Sat Dec 30 2023
Journal Name
Iraqi Journal Of Science
Influence of the Beam Size Radiation on the Depth Dose by Using 60Co
...Show More Authors

Radiotherapy is medical use of ionizing radiation, and commonly applied to the
cancerous tumor because of its ability to control cell growth.
The amount of radiation used in photon radiation therapy called dose (measured
in grey unit), which depend on the type and stage of cancer being treated.
In our work, we studied the dose distribution given to the tumor at different
depths (zero-20 cm) treated with different field size (4×4- 23×23 cm).
Results show that the deeper treated area has less dose rate at the same beam
quality and quantity. Also it has been noted increasing in the field increasing in the
depth dose at the same depth even if the radiation energy is constant. Increasing in
radiation dose attribut

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 04 2013
Journal Name
Iraqi Journal Of Science
Influence of the Beam Size Radiation on the Depth Dose by Using 60Co
...Show More Authors

Radiotherapy is medical use of ionizing radiation, and commonly applied to the cancerous tumor because of its ability to control cell growth. The amount of radiation used in photon radiation therapy called dose (measured in grey unit), which depend on the type and stage of cancer being treated. In our work, we studied the dose distribution given to the tumor at different depths (zero-20 cm) treated with different field size (4×4- 23×23 cm). Results show that the deeper treated area has less dose rate at the same beam quality and quantity. Also it has been noted increasing in the field increasing in the depth dose at the same depth even if the radiation energy is constant. Increasing in radiation dose attributed to the scattere