Preferred Language
Articles
/
ijs-3154
Measurement of Absorbed Dose in Water Using Co-60 gamma source Teletherapy Units According to IAEA Dosimetry Protocols
...Show More Authors

      Modern radiotherapy facilities like 3-Dimensional conformal radio therapy (3DCRT), Intensity Modulated Radiotherapy (IMRT), were recently suggested in Co-60 machine with Multi-leaf Collimator (MLC). In this study, two reference chambers NE-2571#1205 and NE2581#537 were used for absolute dose measurement in Equinox accelerator. A comparison of dose measurement by two different IAEA protocols TRS-277 and TRS-398 has been studied. Analyzing TRS-398, a common shaped empirical formula was developed for the four Co-60 units of four Medical Colleges in Bangladesh with fitting parameters. It was found that an average discrepancy in the determination of absorbed dose in water among the two different protocols TRS-277 and TRS-398 were 1.33 % for the chamber NE-2571#1205 and 0.65 % for the chamber NE2581#537 with combined uncertainty ±1.59 % (k=1). A good convergence has been obtained in the concepts and methods in this study.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Dec 11 2018
Journal Name
Baghdad Science Journal
Thermoluminescence dosimetry of mixed neutron – gamma fields
...Show More Authors

The method of measurement dosimetry in neutron – gamma field by using CaSo4 : Dy (PTFE) disc which has a diameter of 1.3mm and thickness of 0.2mm and using hydrogenated material as a converters of neutron to recoil protons (n-p) reaction, the discs were irradiated by neutron source (241Am-Be) with flux of 4.5?105 n/cm2s for different time to obtain different dose. The TL signals, which we have been obtained by using the converters, are increases to 71%. So we can resolve the neutron and gamma in mixed field.

View Publication Preview PDF
Crossref
Publication Date
Thu Jun 28 2018
Journal Name
Iraqi Journal Of Physics
Measurement of Percentage Depth Dose (PDD) for 6 MeV in water phantom and homogenous actual planning
...Show More Authors

Radiotherapy is the branch of clinical medicine concerned with the application of ionizing radiation in the treatment of disease. And it is used to killing of cancer cells in a tissue using ionizing radiation while keeping the sparing of healthy cells at acceptable level. X-ray beams are used to deposit absorbed dose at depth within a patient at the site of the tumor. The aim of this work is studying the relationship between the depth dose and the field size in water phantom and homogenous actual planning. In our work, the dose distribution at different depths (zero-18 cm) deep at1cm interval treated with field size (10×10 and 20×20) cm2 were studied. Results show that high similarity between water phantom and actual planning for

... Show More
Publication Date
Tue Sep 11 2018
Journal Name
Iraqi Journal Of Physics
Measurement of Percentage Depth Dose (PDD) for 6 MeV in water phantom and homogenous actual planning
...Show More Authors

Radiotherapy is the branch of clinical medicine concerned with the application of ionizing radiation in the treatment of disease. And it is used to killing of cancer cells in a tissue using ionizing radiation while keeping the sparing of healthy cells at acceptable level. X-ray beams are used to deposit absorbed dose at depth within a patient at the site of the tumor. The aim of this work is studying the relationship between the depth dose and the field size in water phantom and homogenous actual planning. In our work, the dose distribution at different depths (zero-18 cm) deep at1cm interval treated with field size (10×10 and 20×20) cm2 were studied.
Results show that high similarity between water phantom and actual planning for th

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed May 24 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Continuous Extraction and Stripping of Neptunium By Fresh and Degradated Tributyle Phosphate Using Co-60 Cell
...Show More Authors

    The behaviour of Np-239 during the Continuous extraction and stripping  was followed . Three Continuous extraction experiments were carried out . In the first experiment the extraction and stripping were carried out by using Tributyl Phosphate / treated odorless kerosene as the organic phase , while the aqueous phase was uranium and neptunium-239 dissolved in 3M HNO3 . In the second experiment irradiation of organic phase up to 30 M rad were carried out , while keeping the aqueous phase as it is in the first experiment. In the third experiment , the acidity of the aqueous phase was 1.5M instead of 3M and keeping the organic phase as it is in experiment 1. The results obtained in tables 1-3 show the possibility of

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 28 2018
Journal Name
Iraqi Journal Of Science
Hypothetical Method for Gamma Dose Rate Assessment to Conditioned Radioactive waste Container
...Show More Authors

Metallic solid radioactive waste class low level - short lived Radioactive Waste

(LL-SL RW) is the main type of radioactive waste generated from decommissioning operations. Transport, storage and disposal regulations require for gamma emitting radioactive waste (mainly by 137Csisotope), that the dose rate in the proximity of the container should stand below a certain threshold. Also, the conditioning technique (using cementation technique) based on certain matrix with specific ratios should be able to attenuate the gamma radiation activity to the minimum level or to acceptable dosage rate at distance of 1m from the container. In this paper ,in absence of suitable labs for waste package assessment ,hypothetical method&n

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 02 2008
Journal Name
Baghdad Science Journal
Using LiF Disc in Thermoluminescence Dosimetry
...Show More Authors

A LiF (TLD-700) PTFED disc has adiameter of (13mm) and thickness of (0.4mm) for study the response and sensetivity of this material for gamma and beta rays by using (TOLEDO) system from pitman company. In order to calibrate the system and studying the calibration factor. Discs were irradiated for Gamma and Beta rays and comparing with the theoretical doses. The exposure range is between 15×10-2 mGy to 1000×10-2 mGy. These doses are within the range of normal radiation field for workers.

View Publication Preview PDF
Crossref
Publication Date
Thu Feb 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
Financial reporting of grants and assistance in government units according to IPSAS23
...Show More Authors

Abstract: -

The purpose of the research is to present and discuss the concept of grants and aid, with the study and analysis of the role and importance of grants and assistance on the activities of In government units, and then to determine the factors of obtaining grants and assistance, and the importance of providing accounting information in order to enhance the financial reporting of grants and assistance. The accounting system of the government and determine the areas of shortness, taking into account the failure to issue a local accounting base to determine the basis of accounting measurement and disclosure of grants and assistance to guide, and this is the starting point of the current research and so has been intr

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Oct 01 2022
Journal Name
Baghdad Science Journal
Modeling Jar Test Results Using Gene Expression to Determine the Optimal Alum Dose in Drinking Water Treatment Plants
...Show More Authors

Coagulation is the most important process in drinking water treatment. Alum coagulant increases the aluminum residuals, which have been linked in many studies to Alzheimer's disease. Therefore, it is very important to use it with the very optimal dose. In this paper, four sets of experiments were done to determine the relationship between raw water characteristics: turbidity, pH, alkalinity, temperature, and optimum doses of alum [   .14 O] to form a mathematical equation that could replace the need for jar test experiments. The experiments were performed under different conditions and under different seasonal circumstances. The optimal dose in every set was determined, and used to build a gene expression model (GEP). The models were co

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Mon Aug 26 2019
Journal Name
Iraqi Journal Of Science
Depth dose measurement in water phantom for two X-ray energies (6MeV and 10MeV) in comparison with actual planning
...Show More Authors

The purpose of this study is to measure doses delivered at different depths in water phantom at vertical position in comparison with the actual planning in order to verify the dose delivered to the tumor in addition to the measurement of the effect penumbra dose to assess the dose leaking to the healthy soft tissue.

     Percentage depth dose (PDD) values was measured at field sizes (5×5,10×10,15×15, and 20×20) cm2, and the depth dose was measured between (0-16) cm deep at 4cm intervals, for both energies 6 MeV and 10 MeV X-ray beam. Other readings were taken at different distances 1cm and 2cm outside of the actual beam in orthogonal directions at depth of 4 cm. These measurements we

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Sat Oct 20 2018
Journal Name
Journal Of Economics And Administrative Sciences
Measuring the performance of government units according to the government accounting system
...Show More Authors

Abstract

This study aims at clarifying the current performance appraisal system in government units and the extent to which they contribute to the development of the performance of these units by evaluating and measuring the performance of these units on an ongoing basis to subject their services to an assessment and measurement process in order to improve the efficiency of these units to reach their objectives efficiently and effectively. (Iraqi hospitals) by trying to determine the possibility of the government accounting system in the process of evaluating performance, through the comparison of financial performance for successive years and different hospitals using the financial and non-financial model of the evaluati

... Show More
View Publication
Crossref