Preferred Language
Articles
/
ijs-6648
Spectroscopic Diagnosis of Cobalt Plasma Produced by OES Technique and Influence of Applied Voltage on Plasma Parameters

     In this work, plasma system that operates at vacuum was designed and built using a sheet of cobalt metal for the purpose of diagnosing plasma and measuring its parameters, as it is very important to know the processes that accompany plasma generation and are closely related to them, including the electron density in the plasma and its temperature. The spectroscopic diagnosis was done by optical emission spectroscopy (OES) which relies on the calculation of the optical radiation emitted by the plasma to describe plasma parameters in the chemical, molecular, and ionic radiator's near environment, and applied to cobalt metal at vacuum D.C high voltage power supply. The results showed the rise of spectral lines intensity with increasing the applied voltage. The maximum peak of argon gas (ArI) was at the wavelength (811.5311) nm and the maximum peak of cobalt metal (CoI) was at the wavelength of 242 nm, where argon gas was used at the fifth flow per minute with variable voltages (13-21) kV. The results also achieved that the values ​​of electron temperature rises from (0.2708-0.6649) eV with the increase in the applied voltage, as well as the electron density from (8.108-13.851)x1017cm-3 with the stability of the argon gas flow rate at 5 l/min. The length of the plasma was measured at different gas flow rates (1-5) l/min and different applied voltages (13-21) kV that were used in this diagnosis.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Apr 06 2024
Journal Name
Indian Journal Of Physics
Scopus
View Publication
Publication Date
Tue Feb 28 2023
Journal Name
Iraqi Journal Of Science
The effect of background argon gas pressure on parameters of plasma produced by Dc- glow discharge

       Non-thermal plasmas have become popular as plasma technology has advanced in various fields, including waste management, aerospace technology, and medicinal applications. They can be used to replace combustion fuels in stationary hall motors and need little effort to keep running for longer periods of time. To improve overall system performance, non-reactive gases such as )Xe, Ar, and Kr) are utilized in pure or mixed form to generate plasma. Since DC glow discharge is a fundamental topic of importance, these gases have been researched. The paper concentrates on 2-D modeling and simulation. DC glow-discharge tubes are utilized with argon gas to create plasma and learn about its properties. The magnitude of t

... Show More
Scopus Crossref
View Publication Preview PDF
Publication Date
Tue Aug 31 2021
Journal Name
Iraqi Journal Of Science
Spectroscopic Analysis of Clove Plasma Parameters Using Optical Emission Spectroscopy

     In the current study, the emission spectra generated from clove were measured under normal atmospheric pressure with different laser energies. Clove is used as a source of essential oil in herbal medicine, in particular as a dynamic analgesic oil in dental and other diseases. For aromatherapy, Antiseptic, antiviral, and antimicrobial agents are also packaged with cloves. Compounds that reduce inflammation tend to battle sore throats, cold, and cough as they display so many advantages. The measured spectrum reveals distinctive lines of clove’s chemical elements. X-ray fluorescent (XRF) and atomic absorption spectrometry (AAS) were used to measure the spectrum generated or absorbed by detecting the presence of va

... Show More
Scopus (9)
Crossref (4)
Scopus Crossref
View Publication Preview PDF
Publication Date
Mon Jun 04 2018
Journal Name
Baghdad Science Journal
The Effect of Gas Flow on Plasma Parameters Induced by Microwave

In this paper, construction microwaves induced plasma jet(MIPJ) system. This system was used to produce a non-thermal plasma jet at atmospheric pressure, at standard frequency of 2.45 GHz and microwave power of 800 W. The working gas Argon (Ar) was supplied to flow through the torch with adjustable flow rate by using flow meter, to diagnose microwave plasma optical emission spectroscopy(OES) was used to measure the important plasma parameters such as electron temperature (Te), residence time (Rt), plasma frequency (?pe), collisional skin depth (?), plasma conductivity (?dc), Debye length(?D). Also, the density of the plasma electron is calculated with the use of Stark broadened profiles

Scopus (11)
Crossref (6)
Scopus Clarivate Crossref
View Publication Preview PDF
Publication Date
Sat Feb 26 2022
Journal Name
Iraqi Journal Of Science
Spectroscopic Analysis of CdO: Fe Plasma Generated by Nd: YAG Laser

     In this work, the optical emission spectrum technique was used to analyze the optical emission spectrum of (CdO: Fe) plasma produced by laser Nd: YAG with a wavelength of (532) nm, a period of 10 ns, and a focal length of 10 cm in the energy range of (200-500) mJ. The electron temperature (Te) was determined using the method of line intensities ratio. Using the Saha-Boltzmann equation, the electron density (ne) was determined. Other plasma parameters such as plasma frequency (fp), Debye length (λD) and Debye number (ND) were also measured. The CdO: Fe (at a mixing ratio of X= 0.5.) plasma spectrum was observed for different energies. As a fu

... Show More
Scopus (13)
Crossref (13)
Scopus Crossref
View Publication Preview PDF
Publication Date
Sun Oct 21 2018
Journal Name
Iraqi Journal Of Physics
Spectroscopic study the plasma parameters for Pb doped CuO prepared by pulse Nd:YAG laser deposition

In this work, plasma parameters such as, the electron temperature )Te(, electron density ne, plasma frequency )fp(, Debye length )λD(
and Debye number )ND), have been studied using optical emission spectroscopy technique. The spectrum of plasma with different values of energy, Pb doped CuO at different percentage (X=0.6, 0.7, 0.8) were recorded. The spectroscopic study for these mixing under vacuum with pressure down to P=2.5×10-2 mbar. The results of electron temperature for X=0.6 range (1.072-1.166) eV, for X=0.7 the Te range (1.024-0.855) eV and X=0.8 the Te is (1.033-0.921) eV. Optical properties of CuO:Pb thin films were determined through the optical transmission method using ultraviolet visible spectrophotometer within the ra

... Show More
Crossref (6)
Crossref
View Publication Preview PDF
Publication Date
Sat Aug 31 2019
Journal Name
Iraqi Journal Of Physics
A Study of the Spectroscopic Performance of Laser Produced CdTe(x):S(1-x) Plasma

Abstract

In this work, the plasma parameters (electron temperature (Te), electron density( ne), plasma frequency (fp) and Debye length (λD)) have been studied by using the spectrometer that collect the spectrum of Laser produce CdTe(X):S(1-X) plasma at X=0.5 with different energies. The results of electron temperature for CdTe range 0.758-0.768 eV also the electron density 3.648 1018 – 4.560 1018 cm-3  have been measured under vacuum reaching 2.5 10-2 mbar .Optical properties of CdTe:S were determined through the optical transmission method using ultraviolet visible spectrophotometer within the r

... Show More
Crossref
View Publication Preview PDF
Publication Date
Sun Jan 13 2019
Journal Name
Iraqi Journal Of Physics
Spectroscopic study for plasma parameters in co-sputtering system

In this work the parameters of plasma (electron temperature Te,
electron density ne, electron velocity and ion velocity) have been
studied by using the spectrometer that collect the spectrum of
plasma. Two cathodes were used (Si:Si) P-type and deposited on
glass. In this research argon gas has been used at various values of
pressures (0.5, 0.4, 0.3, and 0.2 torr) with constant deposition time
4 hrs. The results of electron temperature were (31596.19, 31099.77,
26020.14 and 25372.64) kelvin, and electron density (7.60*1016,
8.16*1016, 6.82*1016 and 7.11*1016) m-3. Optical properties of Si
were determined through the optical transmission method using
ultraviolet visible spectrophotometer with in the range
(

... Show More
Crossref (1)
Crossref
View Publication Preview PDF
Publication Date
Fri Oct 20 2023
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Spectroscopic Diagnostic of Laser-Induced Zn Plasma

The sample's physical characteristics and laser parameters impact the generation and characterization of Laser-Induced Plasma (LIP), which is a relevant phenomenon in many applications. We investigated the effect of laser energy on laser-induced Zn plasma characterization in this study. A Zn plasma with a repeating frequency of 6 Hz, a first wavelength of 1064 nm, a pulse duration of 10 ns, and a laser energy range of 300 mJ to 500 mJ was created using a Q-switched ND: YAG laser. The basic plasma properties, such as electron temperature and density, were estimated using optical emission spectroscopy (OES). The electrons' temperature was measured by the Boltzmann plot method, and the value of the electrons' temperature ranged from 1.6 eV

... Show More
Crossref
View Publication Preview PDF
Publication Date
Fri Mar 03 2023
Journal Name
Iraqi Journal Of Science
The effect of background argon gas pressure on parameters of plasma produced by Dc- glow discharge

Non-thermal plasmas have become popular as plasma technology has advanced in various fields, including waste management, aerospace technology, and medicinal applications. They can be used to replace combustion fuels in stationary hall motors and need little effort to keep running for longer periods of time. To improve overall system performance, non-reactive gases such as )Xe, Ar, and Kr) are utilized in pure or mixed form to generate plasma. Since DC glow discharge is a fundamental topic of importance, these gases have been researched. The paper concentrates on 2-D modeling and simulation. DC glow-discharge tubes are utilized with argon gas to create plasma and learn about its properties. The magnitude of the electron density, increases wi

... Show More