Preferred Language
Articles
/
ijl-208
Stress Urinary Incontinence Treatment Using Vaginal Fractional CO2 Laser (10600nm)
...Show More Authors

Stress urinary incontinence (SUI) is involuntary urine leakage during activities that increase abdominal pressure such as coughing, sneezing and lifting of heavy weights. This is a very common disorder among women with history of multiple vaginal deliveries with an obstructed labor. SUI is considered one of the most distressing problems, especially for younger women, with severe quality of life implications, it caused by the loss of urethral support, usually as a consequence of the supporting structural muscles in the pelvis.

Objective: To prove and demonstrate the effect of a fractional CO2 micro-ablative laser (10600nm) in intra vaginal therapy for treating SUI and achieve a clinical improvement of the urogenital system support.

Methods: This is a prospective, observational study which was conducted over six month from the 1st . of July to 29th of December 2016 in Consultation Gynecologist Clinic in Al-Hila city, Iraq, in patients who complain of SUI. Twenty female patients were included in the study, their age ranged from 30- 69 year, at range (49.5 year ) fifteen patient delivered vaginally, two delivered by cesarean section, two had combined delivery and one was Nulliparous ,all of them received the same treatment protocol. Detailed history about continence assessment, quality of life and sexuality before and after therapy. The fractional CO2 Aphrodite laser was used. The parameters used in each session were energy/(dot)pixel 119.4mJ, pulse duration 900 μs, frequancy1000Hz, and exposure time 300ms /shot with average of shots 34 and in range 26-42, in three sessions four weeks apart between them. The patients were followed for three months started from the beginning of the second session to one month after the last session.

 Results: Thirty-five percent of patients 35%(n=7) were cured ,and these 35% included all patients delivered by cesarean section and one third of patients who delivered vaginally and extensively most of patients were 60%(n=12) improved of their SUI. Patient reported no leakage any more while coughing or sneezing. Only 5%(n=1) not responded was menopause women.

Conclusions: This study shows that micro-ablative fractional CO2 laser is effective can produce a remodeling of vaginal connective tissue without causing damage to surrounding tissue and the group of patients with continence disorder without vaginal delivery achieved marked improvement .

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Aug 18 2020
Journal Name
Journal Of Mechanics Of Continua And Mathematical Sciences
THE COMPARISON OF THE METHODS ESTIMATING THE FRACTIONAL DIFFERENCES OF PARAMETER AND ITS DEPENDENCE ON ESTIMATION THE BEST LINEAR MODEL OF TIME SERIES IN THE ENVIRONMENTAL FIELD
...Show More Authors

View Publication
Crossref
Publication Date
Sun Feb 02 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of Nd-YAG laser-irradiation on fluoride uptake by tooth enamel surface (In vitro)
...Show More Authors

Background: The irradiation of teeth with a laser results in an interaction between the light and the biological constituents of the dental hard substance, which is converted directly into heat.This thermal effect is the cause of the structural and chemical enamel changes.The combined treatment of topical fluoride agent with laser may increase fluoride uptake, and reduce progression of caries-like lesions. The aim of this study was to measure the uptake of the acidulated phosphate fluoride and sodium fluoride to the buccal and lingual caries-like lesion enamel surfaces before and after irradiated by Nd-YAG laser in comparison with matching control group. Materials and methods: The sample consisted of 30 human healthy upper premolar teeth wh

... Show More
View Publication Preview PDF
Publication Date
Sat Aug 31 2019
Journal Name
Iraqi Journal Of Physics
A Study of the Spectroscopic Performance of Laser Produced CdTe(x):S(1-x) Plasma
...Show More Authors

Abstract

In this work, the plasma parameters (electron temperature (Te), electron density( ne), plasma frequency (fp) and Debye length (λD)) have been studied by using the spectrometer that collect the spectrum of Laser produce CdTe(X):S(1-X) plasma at X=0.5 with different energies. The results of electron temperature for CdTe range 0.758-0.768 eV also the electron density 3.648 1018 – 4.560 1018 cm-3  have been measured under vacuum reaching 2.5 10-2 mbar .Optical properties of CdTe:S were determined through the optical transmission method using ultraviolet visible spectrophotometer within the r

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 01 2008
Journal Name
Baghdad Science Journal
Study the Effect of thickness on the Optical Properties Performance of active polymeric laser media
...Show More Authors

The paper include study the effect thickness of the polymeric sample which is manufactured by thermo press way. The sample was used as an active tunable R6G laser media. The remarks show that, when the thickness of the samples is increased, with the same concentration, the spectrum will shift towards the short wavelength, & the quantum fluorescence yield will increased. The best result we obtained for the quantum fluorescence yield is (0.68) at the sample, with thickness (0.304mm) in Ethanol solvent, while when we used the Pure Water as a solvent, we found that the best quantum fluorescence yield is (0.63) at (0.18mm) thickness of the sample.

View Publication Preview PDF
Crossref
Publication Date
Sun Mar 01 2009
Journal Name
Laser And Particle Beams
Surface morphology modifications of human teeth induced by a picosecond Nd:YAG laser operating at 532nm
...Show More Authors

Scopus (11)
Scopus
Publication Date
Sat Feb 09 2019
Journal Name
Journal Of The College Of Education For Women
Optical Design of Laser Zoom Beam Expander at near & far Ranges for Tracked Atmospheric Target
...Show More Authors

In this research, beam expander, BEX, is explained and designed for illuminating the
remote flying target. The BEX is optically designed to be suited for Nd:YAG laser of given
specifications. The BEX is modified to be zoom one to meet the conditions of preventing the
receiving unit; i.e the photodetector, from getting saturated at near and far laser tracking.
Decollimation could be achieved by automatic motor, which controls zoom lens of the BEX
according to the required expansion ratio of beam expander

View Publication Preview PDF
Publication Date
Sun Mar 07 2010
Journal Name
Baghdad Science Journal
The Effect of Fluorine and Hydrogen Concentrations on the Chain Reaction of HF Chemical Laser
...Show More Authors

A numerical investigation has been performed to examine the effect of fluorine concentration on the chain reaction mechanisms and parameters of hydrogen fluoride (HF) chemical laser. The practical difficulties associated with this type of lasers impose that an alternative route might be quite useful. Thus, particular attention was paid to develop a computer program to investigate various processes. The results of this computer simulation program proved their credibility when compared with the little published data. This computer program is called Reaction Rate Simulation Model (RRSM). An entirely new approach to emulate the reaction mechanisms has been followed. The effectiveness of reaction rates in the processes of HF lase

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Mar 01 2019
Journal Name
Iraqi Journal Of Physics
Influence of working pressure and lasing energy of Al plasma in laser-induced breakdown spectroscopy
...Show More Authors

Aluminum plasma was generated by the irradiation of the target
with Nd: YAG laser operated at a wavelength of 1064 nm. The
effect of laser power density and the working pressure on spectral
lines generating by laser ablation, were detected by using optical
spectroscopy. The electron density was measured using the Stark
broadening of aluminum lines and the electron temperature by
Boltzmann plot method it is one of the methods that are used. The
electron temperature Te, electron density ne, plasma frequency
and Debye length increased with increasing the laser peak
power. The electron temperature decrease with increasing gas
pressure.

View Publication Preview PDF
Crossref
Publication Date
Tue Jul 14 2020
Journal Name
Materials Science Forum
The Cyclic Fatigue Behavior for 6061-T6 Al Alloy Shafts Processed by Laser Shock Peening
...Show More Authors

The optimal combination of aluminum quality, sufficient strength, high stress to weight ratio and clean finish make it a good choice in driveshafts fabrication. This study has been devoted to experimentally investigate the effect of applying laser shock peening (LSP) on the fatigue performance for 6061-T6 aluminum alloy rotary shafts. Q-switched pulsed Nd:YAG laser was used with operating parameters of 500 mJ and 600 mJ pulse energies, 12 ns pulse duration and 10 Hz pulse repetition rate. The LSP is applied at the waist of the prepared samples for the cyclic fatigue test. The results show that applying 500 mJ pulse energy yields a noticeable effect on enhancing the fatigue strength by increasing the required number of cycles to fracture the

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Tue Nov 30 2021
Journal Name
Iraqi Journal Of Science
Synthesis and Characteristics of Ag, Cu/Au Core/Shell Nanoparticles Produced by Pulse Laser Ablation
...Show More Authors

Colloidal dispersions of mono Au, Ag , Cu and bimetallic Ag/Au and Cu/Au
core/shell nanoparticles are synthesized by pulsed laser ablation of metals targets
immersed in 5 ml distilled water (DW). Surface Plasmon resonance (SPR) and
particle sizes are characterized by UV-VIS and HRTEM, the X-ray diffraction
shows the structure of core/shell. The Surface Plasmon resonance of the produced
nanoparticles solutions for silver nanoparticles about 402 nm and copper
nanoparticles about 636 nm. While for the core-shell observed two peaks of SPR,
Ag/Au core/shell at (406-516) nm, and Cu/Au core/shell observed one peak at
565nm, because the region of gold and copper close together. The shape and
particle size have been con

... Show More
View Publication Preview PDF