Objective: To review and identify the major drivers for COVID-19 vaccine acceptance. Methods: A scoping review of studies of COVID-19 vaccine perceptions and barriers to using the COVID-19 vaccines. Two search engines, including PubMed and Google Scholar, were purposefully searched. Results: Eight studies from different countries were reviewed to categorize factors influencing people's acceptance of COVID-19 according to the Health Belief Model (HBM). Perceived susceptibility, and severity of the disease (COVID-19), in addition to perceived benefits of COVID-19 vaccination and "cues to action", can enhance vaccination acceptance. In contrast, perceived barriers to the COVID-19 vaccine can increase people's hesitancy to be vaccinated. Conclusions: The HBM domains are successful in the prediction of human behaviors toward preventive measures, including vaccination. In general, high perceived susceptibility, severity, benefits, and minimum barriers should always be maintained to keep the vaccination rate high. Reducing the hesitancy to get the vaccine can be achieved by increasing awareness campaigns about the vaccine's efficacy in preventing infection.
Background: Nursing interventions tailored to the smoking triggers in patients with non-communicable chronic diseases are essential. However, these interventions are scant due to the nature of factors associated with smoking cessation and the poor understanding of the effect of nurse-led intervention in Iraq.Purpose: This study aimed to determine the dominant smoking triggers and examine the effects of a tailored nursing intervention on smoking behavior in patients with non-communicable chronic diseases.Methods: Convenience samples of 128 patients with non-communicable chronic diseases, male and female patients, who were 18-70 years old, were recruited in this quasi-experimental, randomized comparative trial in the outpatient clinic
... Show MoreAn analytical expression for the charge density distributions is derived based on the use of occupation numbers of the states and the single particle wave functions of the harmonic oscillator potential with size parameters chosen to reproduce the observed root mean square charge radii for all considered nuclei. The derived expression, which is applicable throughout the whole region of shell nuclei, has been employed in the calculations concerning the charge density distributions for odd- of shell nuclei, such as and nuclei. It is found that introducing an additional parameters, namely and which reflect the difference of the occupation numbers of the states from the prediction of the simple shell model leads to obtain a remarkabl
... Show MoreIn this research, a factorial experiment (4*4) was studied, applied in a completely random block design, with a size of observations, where the design of experiments is used to study the effect of transactions on experimental units and thus obtain data representing experiment observations that The difference in the application of these transactions under different environmental and experimental conditions It causes noise that affects the observation value and thus an increase in the mean square error of the experiment, and to reduce this noise, multiple wavelet reduction was used as a filter for the observations by suggesting an improved threshold that takes into account the different transformation levels based on the logarithm of the b
... Show MoreThe migration from IPv4 to IPv6 can not be achieved in a brief period, thus both protocols co-exist at certain years. IETF Next Generation Transition Working Group (NGtrans) developed IPv4/IPv6 transition mechanisms. Since Iraq infrastructure, including universities, companies and institutions still use IPv4 protocol only. This research article tries to highlight, discuss a required transition roadmap and extend the local knowledge and practice on IPv6. Also, it introduces a prototype model using Packet tracer (network simulator) deployed for the design and implementation of IPv6 migration. Finally, it compares and evaluates the performance of IPv6, IPv4 and dual stack using OPNET based on QoS metrics such as throughput, delay and point to
... Show MoreDBN Rashid, Asian Quarterly: An International Journal of Contemporary Issue, 2018
KE Sharquie, SA Al-Mashhadani, AA Noaimi, AA Hasan, Journal of Cutaneous and Aesthetic Surgery, 2012 - Cited by 19
This article investigates how an appropriate chaotic map (Logistic, Tent, Henon, Sine...) should be selected taking into consideration its advantages and disadvantages in regard to a picture encipherment. Does the selection of an appropriate map depend on the image properties? The proposed system shows relevant properties of the image influence in the evaluation process of the selected chaotic map. The first chapter discusses the main principles of chaos theory, its applicability to image encryption including various sorts of chaotic maps and their math. Also this research explores the factors that determine security and efficiency of such a map. Hence the approach presents practical standpoint to the extent that certain chaos maps will bec
... Show MoreBackground: The highest concentrations of
blood glucose during the day are usually found
postprandialy. Postprandial hyperglycemia (PPH)
is likely to promote or aggravate fasting
hyperglycemia. Evidence in recent years suggests
that PPH may play an important role in functional
& structural disturbances in different body organs
particularly the cardiovascular system.
Objective: To evaluate the effect of (PPH) as a
risk factor for coronary Heart disease in Type 2
diabetic patients.
Methods: Sixty-three type2 diabetic patients
were included in this study. All have controlled
fasting blood glucose, with HbA1c correlation.
They were all followed for five months period
(from May to October 2008)
Solar activity monitoring is important in our life because of its direct or indirect influence on our life, not only on ionospheric communications. To study solar activity, researchers need measuring and monitoring instruments, these instruments are mostly expensive and are not available in all universities. In this paper, a very low frequency radio receiver had been designed and implemented with components available in most markets to support the researchers, college students, and radio astronomy amateurs with a minimum input voltage less than 100µV, an output voltage less than 135 m V with no distortion and an overall gain of 34dB. A comparison had been done between two circuit structures using a workbench software program and experim
... Show More