A bolted–welded hybrid demountable shear connector for use in deconstructable steel–concrete composite buildings and bridges was proposed. The hybrid connector consisted of a partially threaded stud, which was welded on the flange of a steel section, and a machined steel tube with compatible geometry, which was bolted on the stud. Four standard pushout tests according to Eurocode 4 were carried out to assess the shear performance of the hybrid connector. The experimental results show that the initial stiffness, shear resistance, and slip capacity of the proposed connector were higher than those of traditional welded studs. The hybrid connector was a ductile connector, according to Eurocode 4, with slip capacity higher than 6 mm. A nonlinear finite-element model was calibrated against the pushout tests and found capable of reproducing the experimental behavior with good agreement. The verified finite-element model was then used to conduct a series of parametric studies in order to assess the effect of infilled grout, concrete slab strength, stud diameter, stud tensile strength, tube thickness, and tube tensile strength on the shear resistance and stiffness of the hybrid connector. Based on the experimental and numerical results, a design equation is proposed for the prediction of the shear resistance of the novel connector.
This paper proposes a compact, plasmonic-based 4 × 4 nonblocking switch for optical networks. This device uses six 2 × 2 plasmonic Mach-Zehnder switch (MZS), whose arm waveguide is supported by a JRD1 polymer layer as a high electro-optic coefficient material. The 4 × 4 switch is designed in COMSOL environment for 1550 nm wavelength operation. The performance of the proposed switch outperforms those of conventional (nonplasmonic) counterparts. The designed switch yields a compact structure ( 500 × 70 µ m 2 ) having V π L = 12 V · µ m , 1.5 THz optical bandwidth, 7.7 dB insertion loss, and −26.5 dB crosstalk. The capability of the switch to route 8 × 40 Gbps WDM signal is demonstrated successfully.
... Show MoreDesigning and Standardizing two tests for motor coordination timing for youth basketball players Research submitted by Prof. Faris sami & asst. prof. Wasan hanoon ali & asst. prof. Feras muttasher Baghdad University-College Of Physical Education and Sport Sciences Motor coordination in basketball is considered one of the most important factors for success in skill performance accuracy and speed due to the defensive and offensive situations of the game. The problem of the research lies in the lack of tests that can specify the growth of motor coordination through which the relative change for a number of players can be noticed due to practice and training. The subjects of the research were (30) young league players of National Center for gif
... Show MoreThe problem of the research lies in choosing agility tests suitable to the test taker to observe the relative changes in some players. In addition to that, there are a lot of agility tests that lack special test models that coordinate gender and age. This means the youth basketball player on one hand and time and distance in applying the tests on the other. The importance of the research lies in designing agility tests for youth basketball players to achieve variations in tests a matter that will benefit coaches in their training. The subjects of the research were (30) youth basketball players from the specialized school of the National Center that sponsor gifted basketball players in Baghdad for the season 2014 – 2015. The data was colle
... Show MoreA Modified version of the Generlized standard addition method ( GSAM) was developed. This modified version was used for the quantitative determination of arginine (Arg) and glycine ( Gly) in arginine acetyl salicylate – glycine complex . According to this method two linear equations were solved to obtain the amounts of (Arg) and (Gly). The first equation was obtained by spectrophotometic measurement of the total absorbance of (Arg) and (Gly) colored complex with ninhydrin . The second equation was obtained by measuring the total acid consumed by total amino groups of (Arg) and ( Gly). The titration was carried out in non- aqueous media using perchloric acid in glacial acetic acid as a titrant. The developed metho
... Show MoreThe development of low profile gamma-ray detectors has encouraged the production of small field of view (SFOV) hand-held imaging devices for use at the patient bedside and in operating theatres. Early development of these SFOV cameras was focussed on a single modality—gamma ray imaging. Recently, a hybrid system—gamma plus optical imaging—has been developed. This combination of optical and gamma cameras enables high spatial resolution multi-modal imaging, giving a superimposed scintigraphic and optical image. Hybrid imaging offers new possibilities for assisting clinicians and surgeons in localising the site of uptake in procedures such as sentinel node detection. The hybrid camera concept can be extended to a multimodal detec
... Show More