Delays and disruption are a common issue in both community and personal building programs The problem exists all throughout the world, but it is particularly prevalent in Iraq, where millions of dollars are squandered each time as a outcome. Delays and interruptions may have serious consequences not just for Iraq's construction plans, but also for the country's economic and social status. While numerous studies have been conducted to investigate the factors driving delays and disruption in Iraqi construction projects, slight consideration has been given to by what means project management implements and approaches have affected the occurrence of project delays and disruption. After analyzing the crucial reasons for delays and instability in public and private construction projects in Iraq, this paper aims to improve the recording and recommendations using Project Supervision concepts. A thorough investigation was conducted to identify the critical factors that are causing delays and disruptions in construction projects in Iraq's public and private sectors and present project management application procedures in order to establish recommendations to successfully reduce work disruptions and instability in Iraq This paper identifies the top crucial factors contributing to construction project delays and disruptions in Iraq. It further identifies project management Tools and techniques that, when used appropriately, have the potential to address the major causes of delays and interruptions. Following that, a new set of guidelines for applying Project Management methodologies and strategies to address the identified delay and disruption issues is provided, with the objective of aiding practitioners in minimizing the possibility for construction delays and interruption in Iraqi projects.
The numerical investigation has been performed to study the radiation affected steady state laminar mixed convection induced by a hot inner varied positions circular core in a horizontal rectangular channel for a fully developed flow. To examine the effects of thermal radiation on thermo fluid dynamics behavior in the eccentric geometry channel, the generalized body fitted co-ordinate system is introduced while the finite difference method is used for solving the radiative transport equation. The governing equations which used are continuity, momentum and energy equations. These equations are normalized and solved using the Vorticity-Stream function. After validating numerical results for the case without radiation, the detailed rad
... Show MoreIn individuals with type 2 diabetes mellitus (T2DM), the cannabinoid receptor 1 (CNR1) gene polymorphism has been linked to diabetic nephropathy (DN). Different renal disorders, including DN, have been found to alter cannabinoid (CB) receptor expression and activation. This cross-sectional study aimed to investigate the relationship between CNR1 rs1776966256 and rs1243008337 genetic variants and the risk of developing DN in Iraqi patients with T2DM. The study included 100 patients with T2DM, divided into two groups: 50 with DN and 50 without DN. Genotyping of CNR1 rs1776966256 and rs1243008337 polymorphisms was conducted using PCR in DN patients and control samples. The distribution of rs1776966256 and rs1243008337 genotypes and alleles bet
... Show MoreThe gas material balance equation (MBE) has been widely used as a practical as well as a simple tool to estimate gas initially in place (GIIP), and the ultimate recovery (UR) factor of a gas reservoir. The classical form of the gas material balance equation is developed by considering the reservoir as a simple tank model, in which the relationship between the pressure/gas compressibility factor (p/z) and cumulative gas production (Gp) is generally appeared to be linear. This linear plot is usually extrapolated to estimate GIIP at zero pressure, and UR factor for a given abandonment pressure. While this assumption is reasonable to some extent for conventional reservoirs, this may incur
Steady conjugate natural convection heat transfers in a two-dimensional enclosure filled with fluid saturated porous medium is studied numerically. The two vertical boundaries of the enclosure are kept isothermally at same temperature, the horizontal upper wall is adiabatic, and the horizontal lower wall is partially heated. The Darcy extended Brinkman Forcheimer model is used as the momentum equation and Ansys Fluent software is utilized to solve the governing equations. Rayleigh number (1.38 ≤ Ra ≤ 2.32), Darcy number (3.9 * 10-8), the ratio of conjugate wall thickness to its height (0.025 ≤ W ≤ 0.1), heater length to the bottom wall ratio (1/4 ≤ ≤ 3/4) and inclination angle (0°, 30° and 60°) are the main consid
... Show MoreA study of the Torymid collection of Iraq. resulted in undescribed species of the genus
Liodontonierus Gah. L. longicorpus sp. n. with 2 figures.
The type of groundwater in the studied area is slightly brackish. In general, the dominant water type is calcium-sulfate. The reasons behind these different chemical groundwater types can be referred to the active ion exchange between the groundwater of the Dammam aquifer and Rus Formation. The groundwater of the Dammam unconfined aquifer is not suitable for human drinking in all the parameters properties. The groundwater class is fair in the Qasir Al-Ukhaider area, while the Shebcha area and Al-Salman area are poor class except the eastern part of Al-Salman area is very poor.