Abstract Background: The novel coronavirus 2 (SARS?CoV?2) pandemic is a pulmonary disease, which leads to cardiac, hematologic, and renal complications. Anticoagulants are used for COVID-19 infected patients because the infection increases the risk of thrombosis. The world health organization (WHO), recommend prophylaxis dose of anticoagulants: (Enoxaparin or unfractionated Heparin for hospitalized patients with COVID-19 disease. This has created an urgent need to identify effective medications for COVID-19 prevention and treatment. The value of COVID-19 treatments is affected by cost-effectiveness analysis (CEA) to inform relative value and how to best maximize social welfare through evidence-based pricing decisions. Objective: compare the clinical outcome and the costs of two anticoagulants (heparin and (enoxaparin)) used to treat hospitalized patients with COVID-19 infection. Patients and method: The study was a retrospective review of medical records of adult, non-pregnant, COVID-19 infected hospitalized patients who had baseline and last outcome measurements at Alamal Epidemiology Center, Al-Najaf city from (Augast 2020 to June 2021). The outcome measures included D-dimer, length of stay (LOS), and mortality rate. Only the cost of the medical treatment was considered in the analysis. The pharmacoeconomics analysis was done in three different cost-effectiveness analysis methods. Microsoft Excel spreadsheet and Statistical Package for the Social Sciences software (SPSS), was used to conduct statistical analysis. Kaplan Meier test was used to compare the mortality rate. T-TEST was used to compare the outcomes of the two groups. Results and discussion: two groups were compared, the first group consists of 72 patients who received heparin, and the second group consists of 72 patients who received enoxaparin. COVID-19 infected patients had a higher abnormal average D-dimer (2534.675 ng/dl). No significant differences between both genders with regards to the basal average D-dimer (males= 2649.95 ng/dl, females= 2374.1mg/dl, P-value>0.05). There was a significant difference between patient's ages 60 years and patients <60. (3177.33 ng/dl, 1763.06 ng/dl, P-value <0.05). It seems that, higher D-dimer levels were associated with a higher mortality rate (died=3166.263 ng/dl, survived= 1729.94 ng/dl, P-value <0.05). Heparin was more effective in decreasing D-dimer levels than enoxaparin which inversely increased the D-dimer levels (-24.4 ng/dl/day, +154.701 ng/dl/day, P-value <0.05). Additionally, heparin was more effective in increasing the survival rate compared to enoxaparin (55% vs, 35%, P-value<0.05). Heparin was associated with a longer duration of stay in hospital than enoxaparin but with no significant difference (13.7 days, 12.3 days, P-value >0.05). Concerning the cost, treatment with heparin cost less than enoxaparin (2.08 U.S $, 9.44 U.S $)/per patient/per day. Conclusion: Originator heparin was a more cost-effective anticoagulant therapy compared to originator enoxaparin, it was associated with a lower cost and better effect, treatment with Heparin resulted in positive INB= 11.3, where a positive result means that heparin is more cost-effective than Enoxaparin. All three methods of pharmacoeconomic analysis decide that heparin was more cost-effective than enoxaparin in treating COVID-19 infected patients.
The turning process has various factors, which affecting machinability and should be investigated. These are surface roughness, tool life, power consumption, cutting temperature, machining force components, tool wear, and chip thickness ratio. These factors made the process nonlinear and complicated. This work aims to build neural network models to correlate the cutting parameters, namely cutting speed, depth of cut and feed rate, to the machining force and chip thickness ratio. The turning process was performed on high strength aluminum alloy 7075-T6. Three radial basis neural networks are constructed for cutting force, passive force, and feed force. In addition, a radial basis network is constructed to model the chip thickness ratio. T
... Show MoreIn this paper, the Monte-Carlo simulation method was used to compare the robust circular S estimator with the circular Least squares method in the case of no outlier data and in the case of the presence of an outlier in the data through two trends, the first is contaminant with high inflection points that represents contaminant in the circular independent variable, and the second the contaminant in the vertical variable that represents the circular dependent variable using three comparison criteria, the median standard error (Median SE), the median of the mean squares of error (Median MSE), and the median of the mean cosines of the circular residuals (Median A(k)). It was concluded that the method of least squares is better than the
... Show MoreWater pollution has created a critical threat to the environment. A lot of research has been done recently to use surface-enhanced Raman spectroscopy (SERS) to detect multiple pollutants in water. This study aims to use Ag colloid nanoflowers as liquid SERS enhancer. Tri sodium phosphate (Na3PO4) was investigated as a pollutant using liquid SERS based on colloidal Ag nanoflowers. The chemical method was used to synthesize nanoflowers from silver ions. Atomic Force Microscope (AFM), Scanning Electron Microscope (SEM), and X-ray diffractometer (XRD) were employed to characterize the silver nanoflowers. This nanoflowers SERS action in detecting Na3PO4 was reported and analyzed
... Show MoreNew microphotometer was constructed in our Laboratory Which deals with the determination of Molybdenum (VI) through its Catalysis effect on Hydrogen peroxide and potasum iodide Reaction in acid medium H2SO4 0.01 mM. Linearity of 97.3% for the range 5- 100 ppm. The repeatability of result was better than 0.8 % 0.5 ppm was obtanined as L.U. (The method applied for the determination of Molybdenum (VI) in medicinal Sample (centrum). The determination was compared well with the developed method the conventional method.
In this work, a fiber-optic biomedical sensor was manufactured to detect hemoglobin percentages in the blood. SPR-based coreless optical fibers were developed and implemented using single and multiple optical fibers. It was also used to calculate refractive indices and concentrations of hemoglobin in blood samples. An optical fiber, with a thickness of 40 nanometers, was deposited on gold metal for the sensing area to increase the sensitivity of the sensor. The optical fiber used in this work has a diameter of 125μm, no core, and is made up of a pure silica glass rod and an acrylate coating. The length of the fiber was 4cm removed buffer and the splicing process was done. It is found in practice that when the sensitive refractive i
... Show MoreThe fuzzy assignment models (FAMs) have been explored by various literature to access classical values, which are more precise in our real-life accomplishment. The novelty of this paper contributed positively to a unique application of pentagonal fuzzy numbers for the evaluation of FAMs. The new method namely Pascal's triangle graded mean (PT-GM) has presented a new algorithm in accessing the critical path to solve the assignment problems (AP) based on the fuzzy objective function of minimising total cost. The results obtained have been compared to the existing methods such as, the centroid formula (CF) and centroid formula integration (CFI). It has been demonstrated that operational efficiency of this conducted method is exquisitely develo
... Show MoreIn this study, vegetable tanned leather waste of cow (VTLW-C) is used as adsorbent for removing methyl violet 10B dye from aqueous solution. The VTLW-C adsorbent was characterized by FTIR and SEM in order to evaluate its surface properties before using in adsorption experiments. Batch adsorption method was applied to study the effect of different factors such as weight of leather waste, time of shaking, and starting concentration of methyl violet 10B dye. Different isothermal models such as Langmuir, Freundlich, Temkin and Dubinin-Radushkevich (D–R) were used to analyze the experimental data. Kinetic study proceeds using (PFO) kinetic model and (PSO) kinetic model. The results showed better agreement with the Freundlich model; this means
... Show MoreWe report a new theranostic device based on lead sulfide quantum dots (PbS QDs) with optical emission in the near infrared wavelength range decorated with affibodies (small 6.5 kDa protein-based antibody replacements) specific to the cancer biomarker human epidermal growth factor receptor 2 (HER2), and zinc(II) protoporphyrin IX (ZnPP) to combine imaging, targeting and therapy within one nanostructure. Colloidal PbS QDs were synthesized in aqueous solution with a nanocrystal diameter of ∼5 nm and photoluminescence emission in the near infrared wavelength range. The ZHER2:432 affibody, mutated through the introduction of two cysteine residues at the C-terminus (