Abstract Background: The novel coronavirus 2 (SARS?CoV?2) pandemic is a pulmonary disease, which leads to cardiac, hematologic, and renal complications. Anticoagulants are used for COVID-19 infected patients because the infection increases the risk of thrombosis. The world health organization (WHO), recommend prophylaxis dose of anticoagulants: (Enoxaparin or unfractionated Heparin for hospitalized patients with COVID-19 disease. This has created an urgent need to identify effective medications for COVID-19 prevention and treatment. The value of COVID-19 treatments is affected by cost-effectiveness analysis (CEA) to inform relative value and how to best maximize social welfare through evidence-based pricing decisions. Objective: compare the clinical outcome and the costs of two anticoagulants (heparin and (enoxaparin)) used to treat hospitalized patients with COVID-19 infection. Patients and method: The study was a retrospective review of medical records of adult, non-pregnant, COVID-19 infected hospitalized patients who had baseline and last outcome measurements at Alamal Epidemiology Center, Al-Najaf city from (Augast 2020 to June 2021). The outcome measures included D-dimer, length of stay (LOS), and mortality rate. Only the cost of the medical treatment was considered in the analysis. The pharmacoeconomics analysis was done in three different cost-effectiveness analysis methods. Microsoft Excel spreadsheet and Statistical Package for the Social Sciences software (SPSS), was used to conduct statistical analysis. Kaplan Meier test was used to compare the mortality rate. T-TEST was used to compare the outcomes of the two groups. Results and discussion: two groups were compared, the first group consists of 72 patients who received heparin, and the second group consists of 72 patients who received enoxaparin. COVID-19 infected patients had a higher abnormal average D-dimer (2534.675 ng/dl). No significant differences between both genders with regards to the basal average D-dimer (males= 2649.95 ng/dl, females= 2374.1mg/dl, P-value>0.05). There was a significant difference between patient's ages 60 years and patients <60. (3177.33 ng/dl, 1763.06 ng/dl, P-value <0.05). It seems that, higher D-dimer levels were associated with a higher mortality rate (died=3166.263 ng/dl, survived= 1729.94 ng/dl, P-value <0.05). Heparin was more effective in decreasing D-dimer levels than enoxaparin which inversely increased the D-dimer levels (-24.4 ng/dl/day, +154.701 ng/dl/day, P-value <0.05). Additionally, heparin was more effective in increasing the survival rate compared to enoxaparin (55% vs, 35%, P-value<0.05). Heparin was associated with a longer duration of stay in hospital than enoxaparin but with no significant difference (13.7 days, 12.3 days, P-value >0.05). Concerning the cost, treatment with heparin cost less than enoxaparin (2.08 U.S $, 9.44 U.S $)/per patient/per day. Conclusion: Originator heparin was a more cost-effective anticoagulant therapy compared to originator enoxaparin, it was associated with a lower cost and better effect, treatment with Heparin resulted in positive INB= 11.3, where a positive result means that heparin is more cost-effective than Enoxaparin. All three methods of pharmacoeconomic analysis decide that heparin was more cost-effective than enoxaparin in treating COVID-19 infected patients.
The optimum conditions for the production of neutral protease from local strain Aspergillus niger var carbonarius by solid – state fermentation system (Wheat bran) moisted with 0.2 M phosphate buffer (PH7.0) . the hydration ratio was 1:5 (V:W) . the concentration of inoculum was 1×106 spores per 10 gram of solid materials , initial P H 6.5 and 96 hours of incubation period at 30? C .the enzyme activity was 1300 unit / ml and specific activity was 1550 unit / mg protein .
The Necessity of College of Education for Woman from the Point of view of Students
Power switches require snubbing networks for driving single – phase industrial heaters. Designing these networks, for controlling the maximum allowable rate of rise of anode current (di/dt) and excessive anode – cathode voltage rise (dv/dt) of power switching devices as thyristors and Triacs, is usually achieved using conventional methods like Time Constant Method (TCM), resonance Method (RM), and Runge-Kutta Method (RKM). In this paper an alternative design methodology using Fuzzy Logic Method (FLM) is proposed for designing the snubber network to control the voltage and current changes. Results of FLM, with fewer rules requirements, show the close similarity with those of conventional design methods in such a network of a Triac drivin
... Show MoreThe Electrical power system has become vast and more complex, so it is subjected to sudden changes in load levels. Stability is an important concept which determines the stable operation of the power system. Transient stability analysis has become one of the significant studies in the power system to ensure the system stability to withstand a considerable disturbance. The effect of temporary occurrence can lead to malfunction of electronic control equipment. The application of flexible AC transmission systems (FACTS) devices in the transmission system have introduced several changes in the power system. These changes have a significant impact on the power system protection, due to differences inline impedance, line curre
... Show MoreIn this work, composite materials were prepared by mixing different concentrations of ferrites with polyacrylonitrile (PAN) polymer. Using the electrospinning technique, these composites were deposited on a p-type silicon wafer. The prepared samples demonstrated nanofibers in both pure PAN polymers and their composites with ferrite. Prior to examining the humidity sensing effectiveness with a percentage of relative humidity at a frequency of 10 kHz, based on ambient temperature and a relative humidity range of 50–100%, the composite nanofibers demonstrated stronger humidity sensing compared to the pure PAN nanofibers, which demonstrated a powerful resistance response. More precisely, the PAN@ferrite nanocomposite showed a broad adsorption
... Show More