A total of 20 raw milk samples were used as the fouling agent for evaluating the bacteriological effectiveness of cleaning and sanitizing of domestic milking equipment by using ozonated water at 0.5 ppm comparing to the warm water at 55! for 5 minutes respectively. The mean values of total aerobic bacteria, Coliform and E.coli that present on the plastic and stainless-steel containers after using the raw milk as fouling agent were 3.4×10-6 , 6.7x10-5 and 5.8×10-3 cfu/cm2 respectively , after cleaning the stainless steel containers by the ozonated water the mean values of total aerobic bacterial counts, Coliforms and E.coli bacteria were reduced to 1.2×10-6, 4.7×10-5 and 3.3×10-3 CFU/cm2 respectively. while after cleaning by the warm water were only reduced to 2.3x10-6, 2.7×10-5and 2.8×10-3 CFU/cm2 respectively . The mean values of total aerobic bacteria, coliform ,and E.coli counts/ cm2 after cleaning the plastic containers by the ozonated water were reduced to 1.4×10-6, 1.8×10-5 and 2.4×10- 3 CFU/cm2 respectively, while the mean values after cleaning by the warm water were reduced to 1.1×10-6, 1.7×10-5 and 2.3×10- 3 CFU/cm2 respectively .The mean values of total aerobic, Coliforms and E.coli bacteria after using both the Ozonating and warm water for both stainless steel and plastic containers were reduced to 4.2x10-5, 2.1x10-3, 1.6x10-2, 2.2x10-5, 5.1x10-3 and 1.4x10-2 CFU/cm2 respectively. The results of the current study showed that the independed either treatment by the ozonated or warm water not effectively reduced the number of the quality control bacteria because such reduction in bacterial population could not be enough to guarantee the safety of the home dairy containers, while the combined both treatments had a significant reduction in the population of the quality control bacteria. The effectiveness of cleaning and sanitization by the ozonated and warm water process may be depending on the initial count contaminated bacteria of raw milk, exposure time, kind of containers and both concentration of ozone and the heating temperature.
The main purpose of the research is to demonstrate the importance of the insurance sector in the economy through its role in providing security for all economic sectors and thus stimulating the gross domestic product and reducing dependence on the output of the oil sector, which may expose the Iraqi economy to several problems and imbalances, I have found that there is a great weakness in the role of the insurance sector in Iraq at the level of government, companies and individuals, and the reason for this is the lack of policies supporting the insurance sector and the lack of work in the strategy of economic diversity and the decrease of security awareness by individuals so became Developing the sector to ensure the urgent need
... Show MoreThe complexity and partially defined nature of jet grouting make it hard to predict the performance of grouted piles. So the trials of cement injection at a location with similar soil properties as the erecting site are necessary to assess the performance of the grouted piles. Nevertheless, instead of executing trial-injected piles at the pilot site, which wastes money, time, and effort, the laboratory cement injection devices are essential alternatives for evaluating soil injection ability. This study assesses the performance of a low-pressure laboratory grouting device by improving loose sandy soil injected using binders formed of Silica Fume (SF) as a chemical admixture (10% of Ordinary Portland Cement OPC mass) to di
... Show MoreDrought is a natural phenomenon in many arid, semi-arid, or wet regions. This showed that no region worldwide is excluded from the occurrence of drought. Extreme droughts were caused by global weather warming and climate change. Therefore, it is essential to review the studies conducted on drought to use the recommendations made by the researchers on drought. The drought was classified into meteorological, agricultural, hydrological, and economic-social. In addition, researchers described the severity of the drought by using various indices which required different input data. The indices used by various researchers were the Joint Deficit Index (JDI), Effective Drought Index (EDI), Streamflow Drought Index (SDI), Sta
... Show MoreRecently, the environmental isotopes are adopted to figure out the hydrological processes, recharge areas, flow paths, groundwater origin and the interaction between different watery bodies. Currently, five samples of the rainwater have been collected since January to April 2012, as well as December 2011. Those sampling periods have highest amounts of precipitation events. Meantime, 25 samples of groundwater, 5 of the Lesser Zab River and 3 of overland flow have been picked up during the wet period. The dry sampling of groundwater and the Lesser Zab River has been achieved in summer 2011. The Local Meteoric Water Line lies between Global Meteoric Water Line (GMWL) and East Mediterranean Water Line (EMWL). The lowest, highest and
... Show MoreThe measurement data of the raw water quality of Tigris River were statistically analyzed to measure the salinity value in relation to the selected raw water quality parameters. The analyzed data were collected from five water treatment plants (WTPs) assembled alongside of the Tigris River in Baghdad: Al-Karkh, Al-Karama, Al-Qadisiya, Al-Dora, and Al-Wihda for the period from 2015 to 2021. The selected parameters are total dissolved solid (TDS), electrical conductivity (EC), pH and temperature. The main objective of this research is to predicate a mathematical model using SPSS software to calculate the value of salinity along the river, in addition, the effect of electrical conductivi
In this study, four sampling stations were selected on the Tigris River (Baghdad region) in order to determine concentrations, seasonal variation and pollution intensity assessment of heavy metals (Cd, Zn and Mn) in water, sediments and Barbus xanthpterus fish in this river. The study results showed that the mean concentration of dissolved heavy metals (cadmium, zinc and manganese) were 0.004 ppm, 0.023 ppm and 0.007 ppm, respectively. Whereas, their concentrations in sediments were 1.38 ppm, 86 ppm and 231.4 ppm respectively. Irregular seasonal variation for concentrations of these metals in both sediments and water. The mean concentration of these metals in tissues of fish muscles were 0.0043 ppm, 0.0023 ppm and 0.03 ppm for cadmium, z
... Show MoreThe dialogue considers a method and life curriculum help to solve many problems as well as the best way to build a healthy family setting supports the growth of children and leads to the formation sound, strong and positive character. It also supports the family relationship. many of family members needs may achieve through what prevails among them such as continuing a comprehensive and deep combines word, deed and feeling it enters the body and soul . So each part strengthens by the other part and exchanges effect The deep domestic dialogue opens hearts between parents and children Family increases more loving , intimacy , honesty and happiness. So the domestic dialogue became an urgent necessity in the light of many socia
... Show MoreWheat straw was modified with malonic acid in order to get low cost adsorbent have a good ability to remove copper and ferric ions from aqueous solutions, chemical modification temperature was 120°C and the time was 12 h. Parameters that affect the adsorption experiments were studied and found the optimum pH were 6 and 5 for copper and iron respectively and the time interval was 120 min and the adsorbent mass was 0.1 g. The values for adsorption isotherms parameters were determined according to Langmuir [qmax were 54.64 and 61.7 mg/g while b values were 0.234 and 0.22 mg/l] , Freundlich [Kf were 16.07 and 18.89 mg/g and n were 2.77 and 3.16], Temkin [B were 0.063 and 0.074 j/mol and At were 0.143 and 1.658 l/g] and for Dubinin-Radushkev
... Show MoreAbstract
The removal of water turbidity by using crumb rubber filter was investigated .The present study was conducted to evaluate the effect of variation of influent water turbidity (10, 25 and 50 NTU), media size (0.6and 1.14mm), filtration rate (25, 45 and 65 l/hr) and bed depth (30 and 60 cm) on the performance of mono crumb rubber filter in response to the effluent filtered water turbidity and head loss development, and compare it with that of conventional sand filter.Results revealed that 25 l/hr flow rate and 25 NTU influent turbidity were the best operating conditions. smaller media size and higher bed depth gave the best removal efficiency while higher media size and small bed depth gave lower head
... Show More