Preferred Language
Articles
/
6IZsboYBIXToZYALmInN
Investigation into the Distribution of Erosion-Corrosion in the Furnace Tubes of Oil Refineries
...Show More Authors

Crude oil is one of the most important sources of energy in the world. To extract its multiple components, we need oil refineries. Refineries consist of multiple parts, including heat exchangers, furnaces, and others. It is known that one of the initial operations in the refineries is the process of gradually raising the temperature of crude oil to 370 degrees centigrade or higher. Hence, in this investigation the focus is on the furnaces and the corrosion in their tubes. The investigation was accomplished by reading the thickness of the tubes for the period from 2008 to 2020 with a test in every two year, had passed from their introduction into the work. Where the thickness of more than one point was measured on each tube in the same row and the corrosion rate was extracted for three furnaces, starting from the area of ​​heat transfer by radiation to the heat transfer area of ​​the convection in three different operating units. It was found that the highest percentage corrosion value between the standard tube thickness and the thickness of conduction position was 37% with the conduction zone, and 31% with radiation zone. There, the tubes specification was tested. Five percent Cr-0.5 Moly and the temperature of radiation zone was 578 °C to 613 °C and the stack temperature was 410 °C to 450 °C. So, the results show that the maximum erosion occur at the convection zone.

Scopus Crossref
Publication Date
Wed Jan 26 2022
Journal Name
Nanomaterials
Improved Melting of Latent Heat Storage Using Fin Arrays with Non-Uniform Dimensions and Distinct Patterns
...Show More Authors

Employing phase-change materials (PCM) is considered a very efficient and cost-effective option for addressing the mismatch between the energy supply and the demand. The high storage density, little temperature degradation, and ease of material processing register the PCM as a key candidate for the thermal energy storage system. However, the sluggish response rates during their melting and solidification processes limit their applications and consequently require the inclusion of heat transfer enhancers. This research aims to investigate the potential enhancement of circular fins on intensifying the PCM thermal response in a vertical triple-tube casing. Fin arrays of non-uniform dimensions and distinct distribution patterns were des

... Show More
View Publication
Scopus (52)
Crossref (54)
Scopus Clarivate Crossref
Publication Date
Fri Jun 29 2018
Journal Name
Journal Of Engineering
Experimental Study and Analysis on Degradation of Oily Sludge from Process Equipment by Continuous Hybrid Treatment
...Show More Authors

It is well known that petroleum refineries are considered the largest generator of oily sludge which may cause serious threats to the environment if disposed of without treatment. Throughout the present research, it can be said that a hybrid process including ultrasonic treatment coupled with froth floatation has been shown as a green efficient treatment of oily sludge waste from the bottom of crude oil tanks in Al-Daura refinery and able to get high yield of base oil recovery which is 65% at the optimum operating conditions (treatment time = 30 min, ultrasonic wave amplitude = 60 micron, and (solvent: oily sludge) ratio = 4). Experimental results showed that 83% of the solvent used was recovered meanwhile the main water

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of Engineering
Efficient Energy Management for a Proposed Integrated Internet of Things-Electric Smart Meter (2IOT-ESM) System
...Show More Authors

In this work, an efficient energy management (EEM) approach is proposed to merge IoT technology to enhance electric smart meters by working together to satisfy the best result of the electricity customer's consumption. This proposed system is called an integrated Internet of things for electrical smart meter (2IOT-ESM) architecture. The electric smart meter (ESM) is the first and most important technique used to measure the active power, current, and energy consumption for the house’s loads. At the same time, the effectiveness of this work includes equipping ESM with an additional storage capacity that ensures that the measurements are not lost in the event of a failure or sudden outage in WiFi network. Then then these

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Fri May 01 2015
Journal Name
Journal Of Engineering
Use of non-Conventional Material to Remove Cu+2 ions from Aqueous Solutions using Chemical Coagulation
...Show More Authors

Coagulation - flocculation are basic chemical engineering method in the treatment of metal-bearing industrial wastewater because it removes colloidal particles, some soluble compounds and very fine solid suspensions initially present in the wastewater by destabilization and formation of flocs. This research was conducted to study the feasibility of using natural coagulant such as okra and mallow and chemical coagulant such as alum for removing Cu and increase the removal efficiency and reduce the turbidity of treated water. Fourier transform Infrared (FTIR) was carried out for okra and mallow before and after coagulant to determine their type of functional groups. Carbonyl and hydroxyl functional groups on the surface of

... Show More
View Publication Preview PDF
Publication Date
Fri May 01 2020
Journal Name
Journal Of Engineering
Removal of Acidic Dye from Aqueous Solution Using Surfactant Modified Bentonite (Organoclay): Batch and Kinetic Study
...Show More Authors

Modified bentonite has been used as effective sorbent material for the removal of acidic dye (methyl orange) from aqueous solution in batch system. The natural bentonite has been modified using cationic surfactant (cetyltrimethyl ammonium bromide) in order to obtain an efficient sorbent through converting the properties of bentonite from hydrophilic to organophilic. The characteristics of the natural and modified bentonite were examined through several analyses such as Scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), and Surface area. The batch study was provided the maximum dye removal efficiency of 88.75 % with a sorption capacity of 555.56 mg/g at specified conditions (150 min, pH= 2, 250 rpm, and 0.

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Thu Oct 03 2024
Journal Name
Applied Organometallic Chemistry
Synthesis, Characterization, Molecular Docking, Cytotoxicity, and Antimicrobial Activity of Schiff Base Ligand and Its Metal Complexes
...Show More Authors

A Schiff base ligand (L) was synthesized via condensation of N-( 1-naphthyl) ethylenediamine dihydrochloride with phthalaldehyde. The ligand was characterized by FT-IR, UV–Vis, 1H NMR, mass spectrometry, and elemental analysis (C, H, N). Five metal complexes (Co(II), Ni(II), Cu(II), Zn(II), and Cd(II)) were prepared with the ligand in a 1:1 (M:L) ratio using an aqueous ethanol solution. The complexes were characterized by FT-IR, UV–Vis, mass spectrometry, and elemental analysis (C, H, N). Additionally, 1H NMR spectroscopy was employed for Cd(II) complex. Antimicrobial activity of the ligand and its metal complexes against pathogenic bacteria (K. pneumoniae, E. coli, S. aureus, and S. epidermidis) and fungus (C. albicans) were evaluated

... Show More
Scopus (7)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Thu Oct 03 2024
Journal Name
Applied Organometallic Chemistry
Synthesis, Characterization, Molecular Docking, Cytotoxicity, and Antimicrobial Activity of Schiff Base Ligand and Its Metal Complexes
...Show More Authors
ABSTRACT<p>A Schiff base ligand (L) was synthesized via condensation of <italic>N</italic>‐(1‐naphthyl)ethylenediamine dihydrochloride with phthalaldehyde. The ligand was characterized by FT‐IR, UV–Vis, <sup>1</sup>H NMR, mass spectrometry, and elemental analysis (C, H, N). Five metal complexes (Co(II), Ni(II), Cu(II), Zn(II), and Cd(II)) were prepared with the ligand in a 1:1 (M:L) ratio using an aqueous ethanol solution. The complexes were characterized by FT‐IR, UV–Vis, mass spectrometry, and elemental analysis (C, H, N). Additionally, <sup>1</sup>H NMR spectroscopy was employed for Cd(II) complex. Antimicrobial activity of the ligand and its metal complexes against </p> ... Show More
View Publication
Scopus (7)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Fri Oct 01 2021
Journal Name
Applied Thermal Engineering
Simultaneous and consecutive charging and discharging of a PCM-based domestic air heater with metal foam
...Show More Authors

View Publication
Scopus (68)
Crossref (70)
Scopus Clarivate Crossref
Publication Date
Fri Dec 20 2024
Journal Name
Iraqi Journal Of Pharmaceutical Sciences
Sulfur Derivatives of 1,2,4-Triazole: Recently Developed Compounds, Structure Activity Relationship, and Biological Activity: Review article
...Show More Authors

The term of heterocyclic chemistry focuses only on heterocyclic compounds, which consider as a percentage of organic chemistry, they equal to greater than sixty-five. These compounds are widely founded in nature and most of them are important to life. In the past few years, scientist fused on 1,2,4-triazoles and their condensed heterocyclic ring due to their medicinal significance, 1,2,4-triazole containing Sulphur atom is one of the important heterocyclic moieties due to its broad range of biological activities also their derivatives can accommodate one of the alternatives as electronic effect as exchanges of the electronic density (electron donating or withdrawing) groups ; for all what mentioned above they are consider as a core

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Fri Jun 16 2023
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Formulation and Assessment of Delayed/Slow-Release Diclofenac Sodium Edible Organogel Utilizing Low Molecular Weight Organogelators
...Show More Authors

Organogel as a system was to estimate its capacity to delay and slow the drug release in the duodenum. The gelators, 12HSA (12-hydroxystearic acid), span 60. span 40 were used; the castor oil (CO) and anise oil (AO) also represented the liquid phase. To achieve the goal of this work was by using diclofenac sodium (DS). Organogels specifications were by estimating thermal attitude using tabletop rheology and differential scanning calorimetry (DSC). The organogel strength study was by applying oscillatory rheology tests the amplitude sweep and the frequency sweep. Realizing the morphology of the organogel was done utilizing an optical microscope. CO and AO binding capacity was also manifested. The transition temperatures for all organogels

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (3)
Scopus Crossref