Preferred Language
Articles
/
zRYg4ooBVTCNdQwCzKYY
Effect of pigments of Pseudomonas aeruginosa on adhering and cytotoxicity of A549 cell line
...Show More Authors

Pseudomonas aeruginosa  gram-negative, bacilli and facultative aerobic, P. aeruginosa cause cystic fibrosis patients, wounds, burns, and immunodeficienct patients,  that have many virulence factors such as pyocyanin , cytotoxic ,biofilm formation  and motility, Eighty-eight isolates belonging to P. aeruginosa were collected including the 66 clinical isolates obtained from different hospitals in Baghdad and were from different sources and 22 environmental isolates from previous studies of soil near oil fields. Microscopical and cultural characteristics were studied and diagnosed using biochemical tests, VITEC device, their ability to adhere to non-living (Polystyrene), living cell line (A549) and cytotoxicity of bacterial filtrate by MTT method. The results displayed that all isolates belonged to P. aeruginosa. The pigment-forming (pe26 – pc36) isolates and (PE33 – PC31) non-pigment-forming isolates were selected. That all selected bacteria were able to adhere to the Polystyrene  and an epithelial carcinoma of lung (A549) was of more than 300 colony formation units in dilution (1:10) ,(1:1000), and   (1:10000). The toxicity of the P. aeruginosa filtrate (pc36) isolated from clinical sources and producing pigments was 15.7, 34.5, 44 % at a concentration of 40, 60, 80 % respectively, while the isolate (pc31) that was isolated from clinical sources and non-producing pigment was 28.1, 75.2, 80.9 % at the same concentrations. As for the isolate (pe26),isolated from environmental sources and forming the pigment, the inhibition rate was 38.5, 83.1, 48.8 % at concentrations of 40, 60, 80) % respectively, and the isolate (PE33) that was isolated from environmental sources was 42, 73.4, 74.1 % at concentrations of  40, 60, 80 % respectively. The study will be helpful in evaluating the effect of pigment formation in P. aeruginosa on adhesion.

Scopus Crossref
View Publication
Publication Date
Wed Jul 01 2020
Journal Name
Materials Science Forum
Synthesis, Characterization and Reactivity Ratios of Poly Phenyl Acrylamide-Co-Methyl Methacrylate
...Show More Authors

The monomer phenyl acrylamide was synthesized by reacting acrylamide with chloro benzene in the presence of pyridine. Copolymer of phenyl acrylamide (PAM) with methyl methacrylate (MMA) was synthesized by free radical technique using dimethylsulfoxide (DMSO) as solvent and benzoyl peroxide (BPO) as initiator. The overall conversion was kept low (≤ 15% wt/wt) for all studies copolymers samples. The synthesized copolymers were characterized using fourier transform infrared spectroscopy (FT-IR), and their thermal properties were studied by thermogravimetric analysis (TGA) and differential scanning calorimetry (DSC). The copolymers compositions were determined by elemental analysis. The monomer reactivity ratios have been calculated b

... Show More
View Publication
Scopus (9)
Crossref (2)
Scopus Crossref
Publication Date
Fri Mar 14 2014
Journal Name
Arabian Journal Of Geosciences
Wetting and drying collapse behaviour of collapsible gypseous soils treated by grouting
...Show More Authors

View Publication
Crossref (30)
Crossref
Publication Date
Sun Mar 01 2020
Journal Name
Materials Research Express
Spray pyrolysis of graphene oxide based composite for optical and wettability applications
...Show More Authors
Abstract<p>In this study, silica-graphene oxide nano–composites were prepared by sol-gel technique and deposited by spray pyrolysis method on glass substrate. The effect of changing the graphene/silica ratio on the optical properties and wetting of these nano–structures has been investigated. The structural and morphological properties of the thin films have been studied by x-ray diffraction spectroscopy (XRD), field emission scanning electron microscope (FESEM), energy dispersive x-ray spectroscopy (EDS) and atomic force microscope (AFM). XRD results show that silica structures present in the synthesized films exhibit amorphous character and there is a poor arrangement in graphene plates al</p> ... Show More
View Publication
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Mon Apr 21 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Load-deflection characteristics and force levels of coated nickel titanium orthodontic archwires
...Show More Authors

Background: Coated archwires have been introduced to improve esthetics during orthodontic treatment. Theaim of the present study was to evaluate and compare the load–deflection characteristics and force levels of six brands of coated nickel titanium orthodontic archwires using palatal and gingival deflection. Materials and methods: Ten round wires (0.016 inch) and ten rectangular wires (0.019x0.025 inch) were obtained from each of six brands (G&H, Opal, Ortho Technology, Dany, Hubit and Astar Companies). The load-deflection properties of these archwires were evaluated by the modified bending test usinga readymade dental arch model in both palatal and gingival directions at 37°C temperature using a universal material testing machi

... Show More
View Publication Preview PDF
Publication Date
Wed May 31 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Level of Serum Complements and Immunoglobulins in Iraqi Insulin Dependent Diabetes Mellitus
...Show More Authors

Background: Diabetes mellitus (DM) accompanied with an increase in the death rate and represents a significant public health challenge. It is the cause of other disorders and infection in many body organs. Hence, it is important to study the possible changes in the immunological components in the serum of diabetic patients which are not well understood. In this work, serum C3, C4, IgA, IgG, and IgM were estimated in the patients with insulin dependent diabetes mellitus (IDDM) and compared with healthy persons. Patients and Methods: Twenty-one insulin dependent diabetic patients in addition to twenty-four healthy persons as control group were participated in this study. Serum C3, C4, IgA, IgG, and IgM were measured by using immunodiffusio

... Show More
View Publication Preview PDF
Publication Date
Tue May 16 2023
Journal Name
International Journal Of Online And Biomedical Engineering (ijoe)
Comparative Study of Anemia Classification Algorithms for International and Newly CBC Datasets
...Show More Authors

Data generated from modern applications and the internet in healthcare is extensive and rapidly expanding. Therefore, one of the significant success factors for any application is understanding and extracting meaningful information using digital analytics tools. These tools will positively impact the application's performance and handle the challenges that can be faced to create highly consistent, logical, and information-rich summaries. This paper contains three main objectives: First, it provides several analytics methodologies that help to analyze datasets and extract useful information from them as preprocessing steps in any classification model to determine the dataset characteristics. Also, this paper provides a comparative st

... Show More
View Publication
Scopus (5)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Testing and Commissioning of a Low-Speed Wind Tunnel (LSWT) Test Section
...Show More Authors

The calibration of a low-speed wind tunnel (LSWT) test section had been made in the present work. The tunnel was designed and constructed at the Aerodynamics Lab. in the Mechanical Engineering Department/University of Baghdad. The test section design speed is 70 m/s. Frictional loses and uniformity of the flow inside the test section had been tested and calibrated based on the British standards for flow inside ducts and conduits. Pitot-static tube, boundary layer Pitot tube were the main instruments which were used in the present work to measure the flow characteristics with emphasize on the velocity uniformity and boundary layer growth along the walls of the test section. It is found that the maximum calibrated velocity for empty test s

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Mar 01 2022
Journal Name
Full Text Book Of Minar Congress4
RELATIONSHIP OF ESSENTIALLY SEMISMALL QUASI-DEDEKIND MODULES WITH SCALAR AND MULTIPLICATION MODULES
...Show More Authors

Let R be a ring with 1 and W is a left Module over R. A Submodule D of an R-Module W is small in W(D ≪ W) if whenever a Submodule V of W s.t W = D + V then V = W. A proper Submodule Y of an R-Module W is semismall in W(Y ≪_S W) if Y = 0 or Y/F ≪ W/F ∀ nonzero Submodules F of Y. A Submodule U of an R-Module E is essentially semismall(U ≪es E), if for every non zero semismall Submodule V of E, V∩U ≠ 0. An R-Module E is essentially semismall quasi-Dedekind(ESSQD) if Hom(E/W, E) = 0 ∀ W ≪es E. A ring R is ESSQD if R is an ESSQD R-Module. An R-Module E is a scalar R-Module if, ∀ , ∃ s.t V(e) = ze ∀ . In this paper, we study the relationship between ESSQD Modules with scalar and multiplication Modules. We show that

... Show More
View Publication
Crossref
Publication Date
Tue Oct 08 2002
Journal Name
Iraqi Journal Of Laser
Spatial Response Uniformity of Silicon–Based CdS and PbS Heterojunction Laser Detectors
...Show More Authors

This paper demonstrates the spatial response uniformity (SRU) of two types of heterojunctions (CdS, PbS /Si) laser detectors. The spatial response nonuniformity of these heterojunctions is not significant and it is negligible in comparison with p+- n silicon photodiode. Experimental results show that the uniformity of CdS /Si is better than that of PbS /Si heterojunction

View Publication Preview PDF
Publication Date
Mon Apr 21 2025
Journal Name
Journal Of Engineering
Testing and Commissioning of a Low-Speed Wind Tunnel (LSWT) Test Section
...Show More Authors

The calibration of a low-speed wind tunnel (LSWT) test section had been made in the present work. The tunnel was designed and constructed at the Aerodynamics Lab. in the Mechanical Engineering Department/University of Baghdad. The test section design speed is 70 m/s. Frictional loses and uniformity of the flow inside the test section had been tested and calibrated based on the British standards for flow inside ducts and conduits. Pitot-static tube, boundary layer Pitot tube were the main instruments which were used in the present work to measure the flow characteristics with emphasize on the velocity uniformity and boundary layer growth along the walls of the test section. It is found that the maximum calibrated velocity for empty test sect

... Show More
View Publication