Preferred Language
Articles
/
yBjCfpUBVTCNdQwCki59
Effect of plasma surface treatment of three different CAD/CAM materials on the micro shear bond strength with resin cement (A comparative in vitro study)
...Show More Authors

Objectives: This study aimed to evaluate and compare the effect of plasma treatment versus conventional treatment on the micro shear bond strength (μSBS), surface roughness, and wettability of three different CAD/CAM materials. Materials and methods: Sixty cylindrical specimens (5 mm diameter ×3 mm height) were prepared from three different CAD/CAM materials: Group A: Zirconia, Group B: Lithium disilicate, and Group C: Resin nano-ceramic. Each group was subdivided into two subgroups according to surface treatment used: Subgroup I: Conventional treatment, zirconia was sandblasted with Al2O3, while lithium disilicate and resin nano-ceramic were etched with hydrofluoric acid. Subgroup II: Plasma treatment, the surface of each material was treated with a plasma device (PiezoBrush® PZ3 Handheld Device, Relyon Plasma, Regensburg, Germany). G-Multi PRIMER was applied, then self-adhesive cement (G-CEM ONE) was applied using a split mold (1 mm diameter ×3 mm height), and μSBS was tested in a universal testing machine. The surface roughness was measured using a profilometer. Nine additional specimens of each material for wettability test using an optical tensiometer. Statistical analysis: The data were analyzed using ANOVA and Bonferroni test at a level of significance of 0.05. Results: The highest mean of μSBS was recorded by AII (27.3 MPa), while the lowest was recorded by AI (17.9 MPa). One-way ANOVA test revealed a significant difference among groups. Bonferroni test showed each two subgroups significant difference except subgroups AI, CI and BII, CII, where there was a non-significant difference. For all CAD/CAM materials, conventional treatment increased the surface roughness compared to plasma treatment, while the contact angle decreased after plasma treatment. Conclusion: Plasma treatment increased the μSBS of resin cement to zirconia significantly while not significantly affecting the μSBS of resin nano-ceramic. Conventional treatment of lithium disilicate provided significantly higher μSBS than plasma treatment.

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jan 01 2024
Journal Name
Dental Hypotheses
Evaluation of the Impact of Ozonated Water on Water Sorption and Solubility of Heat Cure Acrylic Resin: An In Vitro Study
...Show More Authors

Introduction: This study aimed to evaluate the impact of ozonated water on water sorption and solubility of heat-cure acrylic resin. Methods: Thirty-three samples of heat-cured acrylic resin were manufactured and divided into three groups: control, immersion for 10 and 20 minutes in ozonated water. Water sorption and water solubility tests were carried out in line with ADA Standard No. 12 for denture-base acrylic resin. Data were analyzed using one-way ANOVA at a significance level of 5%. Results: There was a nonsignificant difference between the control and experimental groups regarding water sorption (P

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Sun Feb 01 2015
Journal Name
Journal Of Engineering
Punching Shear Strength of Self Compacted Ferrocement Slabs
...Show More Authors

This study aims to investigate the behavior and strength of self-compacted ferrocement slabs under punching shear load. Experimental results of thirteen square ferrocement slabs of 500×500 mm simply supported on all edges are presented.  The main parameters investigated include the volume fraction of reinforcement, slab thickness and size of load-bearing plate. The load deflection and cracking characteristics of the tested slabs are studied and compared.  The test results showed that the volume fraction of wire mesh has significant effect on both ultimate load and displacement. The increase of slab thickness leads to decrease in deflection values and increase in stiffness of slabs. Both ductility and stiffness increase as the

... Show More
View Publication Preview PDF
Publication Date
Thu Oct 03 2024
Journal Name
Dentistry 3000
Antimicrobial Efficiency of Hypochlorous Acid Incorporation and its Effect on Surface Properties of Irreversible Hydrocolloid Materials
...Show More Authors

Objective: Conventional approaches for disinfection, including spraying and immersion, resulted in only surface disinfection of impressions. As a result, self-disinfecting impression materials incorporated with antimicrobial compounds require more extensive studies. The incorporation of a disinfectant into irreversible hydrocolloid impression materials could eliminate the need for the disinfection step by conventional approaches, including spraying and immersion which only result in surface disinfection of impressions. The study was aimed to investigate the effect of incorporation of hypochlorous acid in irreversible hydrocolloid materials on antimicrobial efficiency, detail reproduction, and dimensional stability. Materials and

... Show More
View Publication
Scopus Crossref
Publication Date
Mon Aug 01 2022
Journal Name
Baghdad Science Journal
The Patterns of Poisoning Exposure in Different Ages in Duhok Governate: A three Years Study (2016, 2017, 2018)
...Show More Authors

Poisoning with toxic substances accidently or deliberately can be life threatening and especially in some countries that lack the essential tests and facilities to identify the types and causes of these toxic substances. In Iraq, as many other countries, poisoning is one of the chronic public health problems. However, very little literature about the pattern of poisoning cases, types and age is available in Duhok Governorate. Therefore, this study was conducted to determine the most common patterns of poisoning and the related age and gender in Duhok Governorate from 2016-2018, which would possibly contribute to the early diagnosis and treatment of poisoning. The present study was conducted for three years, started from 1st of

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Aip Conference Proceedings
Plasma levels and diagnostic utility of MMP-2 and TIMP-2 in the diagnosis of Iraqi women with breast tumor: A comparative study with Ca 15-3
...Show More Authors

Scopus Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Aip Conference Proceedings
Plasma levels and diagnostic utility of MMP-2 and TIMP-2 in the diagnosis of Iraqi women with breast tumor: A comparative study with Ca 15-3
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Mon Aug 03 2020
Journal Name
Rawal Medical Journal
Surgical fixation and grafting of traumatic distal tibia atrophic nonunion with or without platelet-rich plasma: A comparative study
...Show More Authors

Objective: To compare distal tibia nonunion plating and grafting with and without platelet-rich plasma (PRP) regarding union rate, union time and complications Conclusion: Combining PRP with autologous bone graft results in a higher union rate, less healing duration, less post-operative pain, and more callus formation. (Rawal Med J 202;45:629- 632). Methodology: In this prospective comparative study, 32 patients with nonunion tibia from July 2017 January 2019 were divided into two groups: group A (16 cases) were treated by plating and grafting with PRP and group B (16 cases) were treated by plating and grafting only. Keywords: Tibial nonunion, bone graft, plateletrich plasma. Results: There was higher union rate in group A related to group

... Show More
Preview PDF
Publication Date
Fri Dec 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of Polyamide (Nylon 6) Micro-Particles Incorporation into RTV Maxillofacial Silicone Elastomer on Tear and Tensile Strength
...Show More Authors

Background: The longevity of any prosthesis depends on the materials from which it was fabricated, that is why, defects in the material properties may reduce the service life of prosthesis and necessitate its replacement. The aim of this study was to evaluate the effect of adding different concentrations of Polyamide-6 (Nylon-6) on the tear and tensile strength of A-2186 RTV silicone elastomer. Materials and Methods: 80 samples were fabricated by the addition of 0%, 1%, 3% and 5% by weight PA-6 micro-particles powder to A-2186 platinum RTV silicone elastomer. The study samples were divided into four (4) groups, each group containing 20 samples. One control group was prepared without PA-6 micro particles and three experimental groups were pr

... Show More
View Publication Preview PDF
Crossref (10)
Crossref
Publication Date
Fri Dec 01 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of Polyamide (Nylon 6) Micro-Particles Incorporation into RTV Maxillofacial Silicone Elastomer on Tear and Tensile Strength
...Show More Authors

View Publication
Crossref (10)
Crossref
Publication Date
Wed Dec 31 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Acidity Level on Ions Released and Corrosion of Metal Orthodontic Appliances at Different Time Intervals (An In vitro Study)
...Show More Authors

ABSTRACT Background: This study measured the effects of three parameters pH value, length of immersion and type of archwire on metal ions released from orthodontic appliances. Materials and Methods: Ninety maxillary halves simulated fixed orthodontic appliances that were immersed in artificial saliva of different pH values (6.75, 5 and 3.5) during 28 day period. Three types of archwires were used: stainless steel, nickel titanium and thermal activated nickel titanium. The quantity of nickel and chromium ions was determined with the use of atomic force spectrophotometer while iron ions by spectrophotometer. Each orthodontic set was weighted two times, before the ligation and immersion in the artificial saliva and after 28 days at the end of

... Show More
View Publication Preview PDF