Preferred Language
Articles
/
y-YeBp0BmraWrQ4dH1Gg
Supra Topological Spaces Via Delta-Semi-Open Sets
...Show More Authors

The significance of supra topological spaces as a subject of study cannot be overstated, as they represent a broader framework than traditional topological spaces. Numerous scholars have proposed extensions to supra open sets, including supra semi-open sets, supra delta-open sets and others. In this paper, the concept of supra delta-semi-open set was introduced within the generalizations of the supra topology of sets. Our investigation involves harnessing this category of sets to introduce new notions in these spaces, specifically supra delta-semi-limit points, supra delta-semi-derive points and examining their relationship with supra semi-open. Building upon this set classification, we introduce several additional concepts such as supra delta-semi-symmetric, supra (delta, delta) semi-generalized closed, supra delta-semi-continuous functions, supra semi-kernel-delta sets, supra delta-semi-separation axioms, supra temperate delta-semi 0, 1 spaces and supra delta-semi rho0, 1 spaces, and we have presented several theories that demonstrate cases of equivalence among these ideas under specific conditions. Additionally, we have proven a collection of useful relationships and properties for the aforementioned ideas. Furthermore, the research was enhanced with illustrative and refuting examples.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
New Method for the On-Line Determination of Molybdenum Via New Microphotometric Home Mode Instrument, Using Hight Emitting Diode as a Variable Intensity Radiant Source with a Miniture Photosilicone Diode Detector for System: Molybdenum(VI)-Hydrogen Peroxide-Ammonium Solution
...Show More Authors

This research work aims to the determination of molybdenum (VI) ion via the formation of peroxy molybdenum compounds which has red-brown colour with absorbance wave length at 455nm for the system of ammonia solution-hydrogen peroxide-molybdenum (VI) using a completely newly developed microphotometer based on the ON-Line measurement. Variation of responses expressed in millivolt. A correlation coefficient of 0.9925 for the range of 2.5-150 ?g.ml-1 with percentage linearity of 98.50%. A detection limit of 0.25 ?g.ml-1 was obtained. All physical and chemical variable were optimized interferences of cation and anion were studied classical method of measurement were done and compared well with newly on-line measurements. Application for the use

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Apr 30 2025
Journal Name
Iraqi Journal Of Science
Determination of Cobalt(II) Ion in Various Selected Alloys via Utilizing Continous Flow Injection Analysis ((CFIA) (Nagham-Four Sources of White  Snow LED Arranged in Three Rows Corresponding to Three Detectors Analyzer) (NAG-4SX3-3D)) Analyzer at 0-180o Angle
...Show More Authors

The research study focuses on the efficient and accurate detection and determination of cobalt ions. The detection method involves the formation of brilliant green aggregates with calcium hexacyanoferrate in the presence of nitric acid. (Nagham-four sources of white snow light-emitting diodes arranged in three rows corresponding to three detectors) (The NAG-4SX3-3D Analyzer is an optical, chemical, electronic, and detection tool that receives a cumulative signal (no amplification is required). The total distance travelled is 760 mm with regard to YZ(mV) - tsec (dmm). It was selected for its precise calculation of the energy transducer profile. The linear range for measuring cobalt (II) ions is 0.05 to 20 mM. For concentrations of 5

... Show More
View Publication
Scopus (2)
Crossref (4)
Scopus Crossref