Preferred Language
Articles
/
xha2yIoBVTCNdQwCSqW0
Very‐high‐resolution electrical resistivity imaging of buried foundations of a Roman villa near Nonnweiler, Germany
...Show More Authors
Abstract<p>Electrical resistivity tomography (ERT) methods have been increasingly used in various shallow depth archaeological prospections in the last few decades. These non‐invasive techniques can save time, costs, and efforts in archaeological prospection and yield detailed images of subsurface anomalies. We present the results of quasi‐three‐dimensional (3D) ERT measurements in an area of a presumed Roman construction, using a dense electrode network of parallel and orthogonal profiles in dipole–dipole configuration. A roll‐along technique has been utilized to cover a large part of the archaeological site with a 25 cm electrode and profile spacing, respectively. We have designed a new field procedure, which used an electrode array fixed in a frame. This facilitated a very efficient field operation, and overall a total of 9648 electrode positions were occupied. The 3D ERT inversion results clearly characterize the main structures of the Roman foundations. We compared our high‐resolution 3D electrical resistivity model with findings from archaeological excavations, which have been done in some parts of the surveyed area. The ERT result coincide well with the excavation results, i.e. the location as well as the vertical and horizontal extensions of the structures could be precisely imaged. The ERT results successfully images most parts of the walls, pits and also smaller internal structures of the Roman building; moreover, excavation ditches that had been refilled prior to the ERT survey are delineated as resistivity heterogeneities as well.</p>
Scopus Clarivate Crossref
View Publication
Publication Date
Sat Dec 01 2012
Journal Name
Journal Of Engineering
Different Resolution Merging Methods For Environmental Areas Extraction
...Show More Authors

The usage of remote sensing techniques in managing and monitoring the environmental areas is increasing due to the improvement of the sensors used in the observation satellites around the earth. Resolution merge process is used to combine high resolution one band image with another one that have low resolution multi bands image to produce one image that is high in both spatial and spectral resolution. In this work different merging methods were tested to evaluate their enhancement capabilities to extract different environmental areas; Principle component analysis (PCA), Brovey, modified (Intensity, Hue ,Saturation) method and High Pass Filter methods were tested and subjected to visual and statistical comparison for evaluation. Both visu

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Jun 01 2010
Journal Name
Journal Of The College Of Languages (jcl)
La Fragilité des Personnages du Roman DeMme Bovary de Flaubert
...Show More Authors

Le but de la présente étude est de mettre en lumière la fragilité des personnages dans le roman de "Mme Bovary". En fait, la fragilité n'est pas uniquement propre aux héros de Flaubert. Nous pouvons attribuer cette caractéristique à la plupart des protagonistes du XIXe siècle. Nous pouvons dire qu'aucun auteur n'excelle autant que Flaubert à incarner cette fragilité.

                Flaubert présente un personnage frustré de toute force et de toute volonté comme le personnage d'Emme Bovary.

                Ce personnage n'a pas de confiance en soi, E

... Show More
View Publication Preview PDF
Publication Date
Thu Apr 18 2019
Journal Name
Al-kindy College Medical Journal
Demonstration of the value of diffusion weighted MR imaging for differentiation of benign from malignant breast lesions
...Show More Authors

Background: Radiologic evaluation of breast lesions is being achieved through several imaging modalities. Mammography has an established role in breast cancer screening and diagnosis. Still however, it shows some limitations particulary in dense breast.

Methods : Magnetic resonance imaging is an attractive tool for the diagnosis of breast tumors1 and the use of magnetic resonance imaging of the breast is rapidly increasing as this technique becomes more widely available.1 As an adjunct to mammography and ultrasound, MRI can be a valuable addition to the work-up of a breast abnormality. MRI has the advantages of providing a three-dimensional view of the breast, performing wit

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Aug 01 2022
Journal Name
Journal Of Engineering
Dynamic Behavior of Machine Foundations on layered sandy soil under Seismic Loadings
...Show More Authors

In this paper, a dynamic investigation is done for strip, rectangular and square machine foundation at the top surface of two-layer dry sand with various states (i.e., loose on medium sand and dense on medium sand). The dynamic investigation is performed numerically using finite element programming, PLAXIS 3D. The soil is expected as a versatile totally plastic material that complies with the Mohr-Coulomb yield criterion. A harmonic load is applied at the base with an amplitude of 6 kPa at a frequency of (2 and 6) Hz, and seismic is applied with acceleration – time input of earthquake hit Halabjah city north of Iraq. A parametric study is done to evaluate the influence of changing L/B ratio (Length=12,6,3 m and width=3 m), type of sand

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sun May 01 2016
Journal Name
Journal Of Engineering
Three-Dimensional Finite Element Simulation of the Buried Pipe Problem in Geogrid Reinforced Soil
...Show More Authors

Buried pipeline systems are commonly used to transport water, sewage, natural oil/gas and other materials. The beneficial of using geogrid reinforcement is to increase the bearing capacity of the soil and decrease the load transfer to the underground structures.

This paper deals with simulation of the buried pipe problem numerically by finite elements method using the newest version of PLAXIS-3D software. Rajkumar and Ilamaruthi's study, 2008 has been selected to be reanalyzed as 3D problem because it is containing all the properties needed by the program such as the modulus of elasticity, Poisson's ratio, angle of internal friction. It was found that the results

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 01 2021
Journal Name
Iraqi Journal Of Physics
A Study of Crystallographic and DC Electrical Characteristics of PPy/Ag Nanocomposites
...Show More Authors

ABSTRACT: Polypyrrole and polypyrrole / silver nanocomposites were fabricated by in-situ polymerization employing Ammonium Persulphate as an oxidizing agent. Nanocomposites were synthesized by combining polypyrrole and silver nanoparticles in various weight percentages (0.1%, 0.5%, 3%, 5% and 7% wt.). Crystallographic data were collected using X-ray diffraction.  PPy particles were found to have an orthorhombic symmetry. In contrast, PPy/Ag nanocomposites were reported to have monoclinic structure. The crystallite size was determined by XRD using Scherrer equation and considered to be within 49 nm range. DC conductivity of pelletized samples was evaluated in the temperature range of 323.15k to 453.15k. The conductiv

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jan 24 2019
Journal Name
Al-kindy College Medical Journal
Role of MRI diffusion weighted imaging in differentiation between benign and malignant ovarian masses
...Show More Authors

Background: Characterization of the ovarian masses preoperatively is important to inform the surgeon about the possible management strategies. MRI may be of great help in identifying malignant lesion before surgery. Diffusion Weighted Imaging (DWI) is a sensitive method for changes in proton of water mobility caused by pathological alteration of tissue cellularity, cellular membrane integrity, extracellular space perfusion, and fluid viscosity.

Objective: to study the diagnostic accuracy of DWI in differentiation between benign and malignant ovarian masses.

Type of the study:Cross-sectional study.

Methods: this study included  53with complex

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Feb 27 2020
Journal Name
Iraqi Journal Of Science
Isotopic Study of Springs Near Haditha Dam Western Iraq
...Show More Authors

     Stable isotopic technique and hydrochemistry was used in studying the water resources interaction of near Haditha Reservoir area, western Iraq. Throughout the study area, 14 groundwater samples (Bashina, Zwachi springs and Wells), 8 surface water samples from the study area, and 7 spring samples were analyzed for 2H and 18O stable isotopes and hydrochemical analysis. In this study, the temperature, altitude and continental effects on the isotopic composition of rain water in Iraq were studied. The climate of the study area is classified as semi-arid to arid region. The results show a variation in the isotopic values of Haditha reservoir and Euphrates river. This variation is due to the effect of the low surface area and the

... Show More
View Publication Preview PDF
Scopus (5)
Scopus Crossref
Publication Date
Mon Feb 18 2019
Journal Name
Iraqi Journal Of Physics
Automated method for buried object detecting using ground penetrating radar (GPR) survey
...Show More Authors

  Ground Penetrating Radar (GPR) is a nondestructive geophysical technique that uses electromagnetic waves to evaluate subsurface information. A GPR unit emits a short pulse of electromagnetic energy and is able to determine the presence or absence of a target by examining the reflected energy from that pulse. GPR is geophysical approach that use band of the radio spectrum. In this research the function of GPR has been summarized as survey different buried objects such as (Iron, Plastic(PVC), Aluminum) in specified depth about (0.5m) using antenna of 250 MHZ, the response of the each object can be recognized as its shapes, this recognition have been performed using image processi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jun 20 2023
Journal Name
Baghdad Science Journal
Assessment of image quality of cervical spine complications using Three Magnetic Resonance Imaging Sequences
...Show More Authors

Examining and comparing the image quality of degenerative cervical spine diseases through the application of three MRI sequences; the Two-Dimension T2 Weighed Turbo Spin Echo (2D T2W TSE), the Three-Dimension T2 Weighted Turbo Spin Echo (3D T2W TSE), and the T2 Turbo Field Echo (T2_TFE). Thirty-three patients who were diagnosed as having degenerative cervical spine diseases were involved in this study. Their age range was 40-60 years old. The images were produced via a 1.5 Tesla MRI device using (2D T2W TSE, 3D T2W TSE, and T2_TFE) sequences in the sagittal plane. The image quality was examined by objective and subjective assessments. The MRI image characteristics of the cervical spines (C4-C5, C5-C6, C6-C7) showed significant difference

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Crossref