Preferred Language
Articles
/
vRgI55UBVTCNdQwCZn91
Telescope Mirror Cleaning Using Atmospheric Pressure Multi-Channel Radio Frequency Plasma Jet
...Show More Authors

     In this work, the surface of the telescope’s mirror is cleaned using an atmospheric-pressure radio frequency plasma jet (APRFPJ), which is generated by Argon gas between two coaxial metal electrodes. The RF power supply is set to 2 MHz frequencies with three different power levels: 20, 50, and 80 W. Carbon, that has adhered to the surface, can be effectively removed using the plasma cleaning technique, which also modifies any residual bonds. The cleaned surface was clearly distinguished using an optical emission spectroscopy (OES) technique and a water contact angle (WCA) analyzer for the activation property on their surfaces. The sample showed a super hydrophilic surface at an angle of 1° after 2.5 minutes of plasma treatment, as determined by the WCA technique, and an analysis of its optical properties showed that its reflectance had increased from 75% before cleaning to 98% after cleaning. Using the OES technique, the RF plasma jet's spectrum can be observed to contain the ArI, ArII, and NI lines.

Scopus Crossref
View Publication
Publication Date
Mon Dec 22 2025
Journal Name
Journal Of Baghdad College Of Dentistry
A study to compare the cleaning efficiency of different irrigation systems for macro debris removal in instrumented canals (An in vitro study)
...Show More Authors

Background: Irrigation of the canal system permits removal of residual tissue in the canal anatomy that cannot be reached by instrumentation of the main canals so the aim of this study was to compare and evaluate the efficiency of conventional irrigation system, endoactivator sonic irrigation system,P5 Newtron Satelec passive ultrasonic irrigation and Endovac irrigation system in removing of dentin debris at three levels of root canals and to compare the percentage of dentin debris among the three levels for each irrigation system. Materials and methods: Forty extracted premolars with approximately straight single root canals were randomly distributed into 4 tested groups of 10 teeth each. All canals were prepared with Protaper Universal ha

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 01 2021
Journal Name
Baghdad Science Journal
New Spectral Range Generations from Laser-plasma Interaction
...Show More Authors

            High-intensity laser-produced plasma has been extensively investigated in many studies. In this demonstration, a new spectral range was observed in the resulted spectra from the laser-plasma interaction, which opens up new discussions for new light source generation. Moreover, the characterizations of plasma have been improved through the interaction process of laser-plasma. Three types of laser were incorporated in the measurements, continuous-wave CW He-Ne laser, CW diode green laser, pulse Nd: YAG laser. As the plasma system, DC glow discharge plasma under the vacuum chamber was considered in this research. The plasma spectral peaks were evaluated, where they refer to Nitrogen gas. The results indicated that the

... Show More
View Publication Preview PDF
Scopus (12)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sun Mar 13 2011
Journal Name
Baghdad Science Journal
Extraction and Purification of albumin from Hunan plasma
...Show More Authors

This study includes adescription of Human serum Albumin by amodified using ion- exchange chromatography with manipulated comparison with cold ethanol precipitation method , It has been nticed that this procedure is superior orer the classical method . The Final yield by the new method 69.32% with purity of 83.42% compared with cohn which yield 60.30 % with purity of 80.7 % . The new method prored that it suitable for the pusi Fication of such material because it yield no precipitation material and it increases the Final yield of albumin solutions . • Human serum Albumin . • Albumin purification . • Ion – exchange chromatography . • Human plasma . • Albumin extraction .

View Publication Preview PDF
Crossref
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Electrical, thermal and optical characteristics of plasma torch
...Show More Authors

Non thermal argon plasma needle at atmospheric pressure was constructed. The experimental set up was based on simple and low cost electric components that generate electrical field sufficiently high at the electrodes to ionize various gases which flow at atmospheric pressure. A high AC power supply was used with 9.6kV peak to peak and 33kHz frequency. The plasma was generated using two electrodes. The voltage and current discharge waveform were measured. The temperature of Ar gas plasma jet at different gas flow rate and distances from the plasma electrode was also recorded. It was found that the temperature increased with increasing frequency to reach the maximum value at 15 kHz, and that the current leading the voltage, which demonstra

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Dec 01 2023
Journal Name
Iraqi Journal Of Physics
Characterization of Magnetized-Plasma System Induced by Laser
...Show More Authors

  This study investigated the effect of applying an external magnetic field on the characteristics of laser-induced plasma, such as its parameters plasma, magnetization properties, emission line intensities, and plasma coefficients, for plasma induced from zinc oxide: aluminum composite (ZO:AL) at an atomic ratio of 0.3 %. Plasma properties include magnetization and emission line intensities. The excitation was done by a pulsed laser of Nd:YAG with 400 mJ energy at atmospheric pressure. Both the electron temperature and number density were determined with the help of the Stark effect principle and the Boltzmann-Plot method. There was a rise in the amount of (ne) and (Te) that was produced

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Fri Oct 01 2010
Journal Name
Iraqi Journal Of Physics
Correlation of Paschen parameters in magnetized argon plasma
...Show More Authors

A number of glow discharge experiments has been carried out in a relatively large-volume metallic vacuum chamber containing argon at low pressure and immersed in an inhomogeneous magnetic field generated by a solenoidal coil capable of delivering 2100G. Two Paschen curves demonstrating the dependence of the discharge voltage on sparking parameter Pd and magnetic field strength B were deduced. A graphical correlation showing the behaviour of the voltage difference from the two curves on the ratio B/Pd was constructed. Investigations showed a reduction in the nominal impedance of the discharge device of nearly 20% when B reaches a value of 525G. Plasma confinement regions were found around the internal surface of the chamber at the entranc

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Energy Procedia
Electron Contribution to Stopping Power in Burning Plasma
...Show More Authors

The dependence of the energy losses or the stopping power for the energies and the related penetrating factor are arrive by using a theoretical approximation models. in this work we reach a compatible agreement between our results and the corresponding experimental results.

View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Mon Dec 22 2025
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Effect of Temperature and Frequency on the Dielectric Properties of PVC/MnCl2 Composite
...Show More Authors

View Publication
Publication Date
Thu Sep 01 2022
Journal Name
Journal Of Medicine And Life
Arrhythmia related to hypertensive left ventricular hypertrophy in Iraqi patients: frequency and outcome
...Show More Authors

Left ventricular hypertrophy (LVH) caused by high blood pressure is linked to increased mortality and arrhythmia risk. This study aimed to evaluate arrhythmia in hypertensive patients due to left ventricular hypertrophy (LVH). A cross-sectional study was performed, assessing participants' blood pressure, echocardiography and electrocardiography, and Holter monitoring in certain cases. There were 300 hypertensive patients >18 years attending the cardiology unit of Baghdad medical city. The study was conducted between January–June 2022. The electrocardiograms at rest for 300 adults with hypertension were investigated. 130 (43.5%) were females, and 170 (56.5%) were males. The mean age of participants was 58 years. Forty-nine (16.3

... Show More
View Publication
Scopus (13)
Crossref (11)
Scopus Crossref
Publication Date
Fri Sep 01 2017
Journal Name
International Journal Of Science And Nature
FREQUENCY OF LOW BIRTH WEIGHT AMONG NEONATES ADMITTEDTO THE NEONATAL INTENSIVE CARE UNIT
...Show More Authors