Preferred Language
Articles
/
uBd7MI8BVTCNdQwCl19h
Cleaning efficacy and instrumentation time using rotary file system in primary molars (comparative study)
...Show More Authors

ABSTRACT— In primary teeth, root canal treatment is a time consuming and challenging procedure, particularly during the most important step in endodontic treatment which is the preparation of the canal. Pulpectomy is the treatment of choice in all the necrotic primary teeth. For better treatment protocol, advancing technology brought the rotary system to reduce the manual dexterity and improve the quality of treatment for pulpectomy. This study aimed to compare and assess the efficacy of cleaning and the time required for the instrumentation during the preparation of root canals of the primary molars using the rotary and the manual (conventional) systems. Thirty root canals of primary teeth were selected. These teeth submitted to access opening and then all the canals injected with Indian ink. Then, 48 hours later, the teeth were randomly classified into two groups: group A (n=fifteen tooth): where the manual preparation of the root canals was done by stainless steel K- files, while group B (n= fifteen tooth): consisted of the root canals that prepared with rotary two shape system. The total instrumentation time was measured using a digital stopwatch. After that, a disk bur was used to section the roots. Then, a digital camera was used to photograph the specimens to evaluate the root canal cleaning. The cleaning efficacy was compared at the coronal, middle and apical level. In the coronal third, rotary two shape system showed more removal to the ink than the K-file with statistical significant difference (p <0.05), however, for the middle third of the canal, no statistical difference was found between the two systems (p=0.05). While at the apical level, K-file showed more removal to the ink than the rotary two shape system and with statistical significant difference (p <0.05). Evaluation of the total samples revealed no statistical significant difference concerning the efficacy of cleaning between K-files and rotary two shape system files. The group that was rotary prepared took less time for the canal preparation as compared to the manual group (80.063 sec., 144.576 sec. respectively). No significant difference was found between the two systems concerning the cleaning efficacy. Instrumentation done by the rotary system took significantly less time than that of the manual. KEYWORDS: Cleaning efficacy, manual instrumentation, primary teeth, rotary instrumentation.

Publication Date
Sat Jul 28 2018
Journal Name
Journal Of Engineering
Experimental and Numerical Study Effect of Using Nanofluids in Perforated Plate Fin Heat Sink for Electronics Cooling
...Show More Authors

An experimental and numerical investigation of the effect of using two types of nanofluids with suspending of (Al2O3 and CuO) nanoparticles in deionized water with a volume fraction of (0.1% vol.), in addition to use three types of fin plate configurations of (smooth, perforated, and dimple plate) to study the heat transfer enhancement characteristics of commercial fin plate heat sink for cooling computer processing unit. All experimental tests under simulated conditions by using heat flux heater element with input power range of (5, 16, 35, 70, and 100 W). The experimental parameters calculated are such as water and nanofluid as coolant with Reynolds number of (7000, 8000, 9400 and 11300); the air

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Sep 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Microleakage of Pit and Fissure Sealants after Using Different Occlusal Surface Preparation Techniques: An In Vitro Study
...Show More Authors

Background: The marginal seal is essential for sealant success because penetration of bacteria under the sealant might allow caries onset or progression. The aim of the present study was to estimate and compare the microleakage of pit and fissure sealant after various methods of occlusal surface preparation. Materials and methods: Thirty non-carious premolars extracted for orthodontic reasons were equally divided into three groups. In group one, occlusal fissures were opened with round carbide bur, in group two, occlusal surfaces of the teeth were cleaned with a dry pointed bristle brush and samples of group three were cleaned with a slurry of fine flour of pumice in water using rubber cup. Then fissures of all teeth were etched using 35% p

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Apr 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
Study and Diagnosis of the Poverty Phenomenon in Rural Areas of Iraq Using the Traditional Method (Crisp)
...Show More Authors

Poverty is defined as a low standard of living in the sense that a poor person can not afford a minimum standard of living. The phenomenon of poverty is one of the most serious problems that must be dealt with seriously. This phenomenon has persisted in Iraq for decades because of the harsh economic conditions and unstable security conditions due to the crises it has faced since 2013. This study requires much study and analysis. And rural areas as a special case. In this study, the researcher examined the poverty line as a criterion in estimating the poverty indicators, which include (poverty percentage H, poverty gap PG, poverty intensity PS), based on the continuous social and economic survey data for households in 2014. The ma

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Sep 25 2017
Journal Name
Biomedical And Pharmacology Journal
Comparative Study of the Effect of Incorporating SiO2 Nano-Particles on Properties of Poly methyl Methacrylate Denture Bases
...Show More Authors

View Publication
Crossref (26)
Crossref
Publication Date
Fri Feb 25 2022
Journal Name
Open Access Macedonian Journal Of Medical Sciences
Prospective Comparative Study of Fixing Displaced Transverse Patellar Fracture by Tension Band Wiring Versus Cannulated Screws with Wiring
...Show More Authors

BACKGROUND: Transverse fractures of the patella are important fractures with a wide variety of subtypes, the common incidence in the age group of 20–50 years. Surgical interference aims to achieve a perfect alignment of the joint surface, in addition to rigid fixation of the fracture for early re-habitation and early movement to retain the extensor mechanism of the knee joint. AIM: The aim of this study was to compare the radiological and functional outcomes of the displaced transverse patella fracture in adult patients treated by ORIF using tension band wiring versus cannulated screws with wiring. METHODS: A prospective analytic comparative study was conducted in Al-Kindy Teaching Hospital/Baghdad/Iraq for 18 months from Apr

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Mon Oct 02 2023
Journal Name
Journal Of Engineering
Controlling the Unbalanced Voltages of a Series-Connected Lead-Acid Batteries in a PV Power Storage System using Dynamic Capacitor Technique
...Show More Authors

Lead-acid batteries have been used increasingly in recent years in solar power systems, especially in homes and small businesses, due to their cheapness and advanced development in manufacturing them. However, these batteries have low voltages and low capacities, to increase voltage and capacities, they need to be connected in series and parallel. Whether they are connected in series or parallel, their voltages and capacities must be equal otherwise the quality of service will be degraded. The fact that these different voltages are inherent in their manufacturing, but these unbalanced voltages can be controlled. Using a switched capacitor is a method that was used in many methods for balancing voltages, but their respons

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Dec 01 2012
Journal Name
Iraqi Journal Of Physics
Power dissipation and time of breakdown in AC discharge of argon at a low pressure in the frequency range 5-10 kHz
...Show More Authors

The influence of 5-10 kHz audio frequency on the power dissipation in ac discharge of argon gas was studied experimentally, at pressures 50-80 mTorr and electrodes separation 10 cm (pd range 0.5-0.8 Torr.
cm). The measurements have shown that the discharge behavior in the ac circuit is equivalent to a series RC circuit. It is observed that the variation curve of discharge power P with the frequency f is approximately has a Gaussian shape. It is also observed that the curve of Pm- pd is the inverse of Paschen curve, where Pm is the maximum power in the frequency range. The time of breakdown is estimated from the curve of P- f.

View Publication Preview PDF
Publication Date
Wed May 20 2026
Journal Name
Al–bahith Al–a'alami
Foreign Propaganda in the Electronic Press about the Syrian Crisis A Comparative Study of the Sites of Russia Today and Alhurra - A research drawn from a Master Degree thesis
...Show More Authors

The research problem lies in the ambiguity of the usage of propaganda contents by two main media outlets (the Russian RT and American Alhurra) in their news coverage of the Syrian crisis through their websites and the methods used by them to convince users taking into account the mutual propaganda conflict between the United States and Russia in the war against Syria. The objectives of the research can be represented by the following: investigating the contents of American and Russian electronic propaganda towards Syrian crisis.
• Identifying the contents that received most of the coverage in the Syrian crisis by the two news outlets.
• Identifying the terms and phrases that have been most used by the websites of RT and Alhurr

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Aug 15 2024
Journal Name
Al-rafidain Journal Of Medical Sciences ( Issn 2789-3219 )
The Impact of the Chlorhexidine Gel (WISDOM®) on Postoperative Sequelae Associated with the Surgical Removal of Impacted Mandibular Third Molars: A Randomized Controlled Clinical Trial
...Show More Authors

Background: One of the most prevalent procedures in oral surgery is the removal of impacted mandibular third molars, typically accompanied by trismus, edema, and pain. Several methods and biomaterials were implemented to mitigate or avoid these surgical problems. Objectives: To evaluate the efficiency of chlorhexidine gel (WISDOM®) in minimizing postoperative sequelae associated with the impacted mandibular third molar that will be surgically extracted and its role in promoting early soft tissue closure of the surgical site. Methods: The study design was a double-masked and randomized, controlled clinical study that included healthy patients needing the removal of a mandibular third molar through surgery. The participants were rand

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Lecture Notes In Networks And Systems
Advanced Security Technique in Presence of Open Communication System and Cyber Era
...Show More Authors

View Publication
Scopus Crossref