Preferred Language
Articles
/
uBd7MI8BVTCNdQwCl19h
Cleaning efficacy and instrumentation time using rotary file system in primary molars (comparative study)
...Show More Authors

ABSTRACT— In primary teeth, root canal treatment is a time consuming and challenging procedure, particularly during the most important step in endodontic treatment which is the preparation of the canal. Pulpectomy is the treatment of choice in all the necrotic primary teeth. For better treatment protocol, advancing technology brought the rotary system to reduce the manual dexterity and improve the quality of treatment for pulpectomy. This study aimed to compare and assess the efficacy of cleaning and the time required for the instrumentation during the preparation of root canals of the primary molars using the rotary and the manual (conventional) systems. Thirty root canals of primary teeth were selected. These teeth submitted to access opening and then all the canals injected with Indian ink. Then, 48 hours later, the teeth were randomly classified into two groups: group A (n=fifteen tooth): where the manual preparation of the root canals was done by stainless steel K- files, while group B (n= fifteen tooth): consisted of the root canals that prepared with rotary two shape system. The total instrumentation time was measured using a digital stopwatch. After that, a disk bur was used to section the roots. Then, a digital camera was used to photograph the specimens to evaluate the root canal cleaning. The cleaning efficacy was compared at the coronal, middle and apical level. In the coronal third, rotary two shape system showed more removal to the ink than the K-file with statistical significant difference (p <0.05), however, for the middle third of the canal, no statistical difference was found between the two systems (p=0.05). While at the apical level, K-file showed more removal to the ink than the rotary two shape system and with statistical significant difference (p <0.05). Evaluation of the total samples revealed no statistical significant difference concerning the efficacy of cleaning between K-files and rotary two shape system files. The group that was rotary prepared took less time for the canal preparation as compared to the manual group (80.063 sec., 144.576 sec. respectively). No significant difference was found between the two systems concerning the cleaning efficacy. Instrumentation done by the rotary system took significantly less time than that of the manual. KEYWORDS: Cleaning efficacy, manual instrumentation, primary teeth, rotary instrumentation.

Publication Date
Mon Dec 23 2019
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Design, Synthesis and Cytotoxicity Study of Primary Amides as Histone Deacetylase Inhibitors
...Show More Authors

Primary amide derivatives as histone deacetylase inhibitors (HDACIs) are very rare. This paper describes the synthesis of primary amide derivatives (compounds 6 and 7) that have the requirements to be histone deacetylase inhibitors of the zinc-binding type. Both of them exhibited good cytotoxicity against the tested cancer cell lines with much lower cytotoxicity against normal cell line.

View Publication Preview PDF
Scopus (7)
Crossref (2)
Scopus Crossref
Publication Date
Sat Sep 01 2007
Journal Name
Al-khwarizmi Engineering Journal
A Fully Computerized Method to Backup the Router Configuration File
...Show More Authors

This paper presents a fully computerized method to backup the router configuration file. The method consists of a friendly graphical interface programmed by Java programming language.

    The proposed method is compared with the two existing methods, namely: TFTP server method and Copy/Paste method. The comparison reveals that the proposed method has many advantages over the existing ones. The proposed method has been implemented on Cisco routers (series 2500, 2600 and 2800).

View Publication Preview PDF
Publication Date
Sun Sep 01 2013
Journal Name
International Journal Of Advanced Research In Computer Science And Software Engineering
Real Time Motion Detection in Surveillance Camera Using MATLAB
...Show More Authors

Surveillance cameras are video cameras used for the purpose of observing an area. They are often connected to a recording device or IP network, and may be watched by a security guard or law enforcement officer. In case of location have less percentage of movement (like home courtyard during night); then we need to check whole recorded video to show where and when that motion occur which are wasting in time. So this paper aims at processing the real time video captured by a Webcam to detect motion in the Scene using MATLAB 2012a, with keeping in mind that camera still recorded which means real time detection. The results show accuracy and efficiency in detecting motion

Preview PDF
Publication Date
Sat Aug 01 2015
Journal Name
Journal Of Engineering
A Real-Time Fuzzy Load Flow and Contingency Analysis Based on Gaussian Distribution System
...Show More Authors

Fuzzy logic is used to solve the load flow and contingency analysis problems, so decreasing computing time and its the best selection instead of the traditional methods. The proposed  method is very accurate with outstanding computation time, which made the fuzzy load flow (FLF) suitable for real time application for small- as well as large-scale power systems. In addition that, the FLF efficiently able to solve load flow problem of ill-conditioned power systems and contingency analysis. The FLF method using Gaussian membership function requires less number of iterations and less computing time than that required in the FLF method using triangular membership function. Using sparsity technique for the input Ybus sparse matrix data gi

... Show More
View Publication Preview PDF
Publication Date
Wed Oct 31 2018
Journal Name
Heat Transfer-asian Research
Comparative study on heat transfer enhancement of nanofluids flow in ribs tube using CFD simulation
...Show More Authors

View Publication
Scopus (20)
Crossref (15)
Scopus Clarivate Crossref
Publication Date
Sun Jul 31 2022
Journal Name
Iraqi Journal Of Science
A Comparative Study Using DCT, Delta Modulation, and Double Shift Coding for Compressing Electroencephalogram Data
...Show More Authors

      Storing, transferring, and processing high-dimensional electroencephalogram (EGG) signals is a critical challenge. The goal of EEG compression is to remove redundant data in EEG signals. Medical signals like EEG must be of high quality for medical diagnosis. This paper uses a compression system with near-zero Mean Squared Error (MSE) based on Discrete Cosine Transform (DCT) and double shift coding for fast and efficient EEG data compression. This paper investigates and compares the use or non-use of delta modulation, which is applied to the transformed and quantized input signal. Double shift coding is applied after mapping the output to positive as a final step. The system performance is tested using EEG data files from the C

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (2)
Scopus Crossref
Publication Date
Thu Feb 07 2019
Journal Name
Iraqi Journal Of Laser
Gingival Enlargement Management using Diode Laser 940 nm and Conventional Scalpel Technique (A Comparative Study)
...Show More Authors

Diode lasers are becoming popular in periodontal surgery due to their highly absorption by pigments such as melanin and hemoglobin their weak absorption by water and hydroxyapatite makes them safe to be used around dental hard tissues. Objective: The aim of the present study was to evaluate the efficiency of diode laser in performing gingivectomy in comparison to conventional scalpel technique in patients with chronic inflammatory enlargement. Materials and methods: Thirty patients were selected for this study. All of them required surgical treatment of gingival enlargements and were randomly divided into two groups: Control group (treated by scalpel and include sixteen patients) and study group (treated with diode laser 940nm and includ

... Show More
View Publication Preview PDF
Publication Date
Sat Apr 01 2023
Journal Name
Journal Of Engineering
Comparative Study of Water Desalination using Reverse Osmosis (RO) and Electro-dialysis Systems (ED): Review
...Show More Authors

The increasing drinking water demand in many countries leads to an increase in the use of desalination plants, which are considered a great solution for water treatment processes. Reverse osmosis (RO) and electro-dialysis (ED) systems are the most popular membrane processes used to desalinate water at high salinity. Both systems work by separating the ionic contaminates and disposing of them as a brine solution, but ED uses electrical current as a driving force while RO uses osmotic pressure. A direct comparison of reverse osmosis and electro-dialysis systems is needed to highlight process development similarities and variances. This work aims to provide an overview of previous studies on reverse osmosis and electro-dial

... Show More
View Publication Preview PDF
Crossref (8)
Crossref
Publication Date
Sun Jan 01 2006
Journal Name
Journal Of Engineering
SELF ORGANIZING FUZZY CONTROLLER FOR A NON-LINEAR TIME VARYING SYSTEM
...Show More Authors

This paper proposes a self organizing fuzzy controller as an enhancement level of the fuzzy controller. The adjustment mechanism provides explicit adaptation to tune and update the position of the output membership functions of the fuzzy controller. Simulation results show that this controller is capable of controlling a non-linear time varying system so that the performance of the system improves so as to reach the desired state in a less number of samples.

Publication Date
Wed Jul 12 2023
Journal Name
Energies
Finite Time Disturbance Observer Based on Air Conditioning System Control Scheme
...Show More Authors

A novel robust finite time disturbance observer (RFTDO) based on an independent output-finite time composite control (FTCC) scheme is proposed for an air conditioning-system temperature and humidity regulation. The variable air volume (VAV) of the system is represented by two first-order mathematical models for the temperature and humidity dynamics. In the temperature loop dynamics, a RFTDO temperature (RFTDO-T) and an FTCC temperature (FTCC-T) are designed to estimate and reject the lumped disturbances of the temperature subsystem. In the humidity loop, a robust output of the FTCC humidity (FTCC-H) and RFTDO humidity (RFTDO-H) are also designed to estimate and reject the lumped disturbances of the humidity subsystem. Based on Lyapunov theo

... Show More
View Publication
Scopus (5)
Crossref (3)
Scopus Clarivate Crossref