Sub-threshold operation has received a lot of attention in limited performance applications.However, energy optimization of sub-threshold circuits should be performed with the concern of the performance limitation of such circuit. In this paper, a dual size design is proposed for energy minimization of sub-threshold CMOS circuits. The optimal downsizing factor is determined and assigned for some gates on the off-critical paths to minimize the energy at the maximum allowable performance. This assignment is performed using the proposed slack based genetic algorithm which is a heuristic-mixed evolutionary algorithm. Some gates are heuristically assigned to the original and the downsized design based on their slack time determined by static timing analysis. Other gates are subjected to the genetic algorithm to perform an optimal downsizing assignment taking into account the previous assignments. The algorithm is applied for different downsizing factors to determine the optimal dual size for low energy operation without a performance degradation. Experimental results are obtained for some ISCAS-85 benchmark circuits such as 74283, 74L85, ALU74181, and 16 bit ripple carry adder. The proposed design shows an energy per cycle saving ranged from (29.6% to 56.59%) depending on the utilization of available slack time from the off-critical paths. © School of Engineering, Taylor’s University.
the study including isolation and identification of candida spp causing UTIs from patintes coming to al-yarmouk hospital
B3LYP density functional is utilized for probing the effect of decorating Al, Ga, and In on the sensing performance of a boron phosphide nanotube (BPNT) in detecting the 2-chloroethanol (CHE) molecule. We predict that the interaction of pure BPNT with CHE is physisorption, and the sensing response (SR) of BPNT is approximately 6.3. The adsorption energy of CHE is about − 26.3 to − 91.1, − 96.6, and − 100.3 kJ/mol, when the Al, Ga, and In metals are decorated on the BPNT surface, respectively. This indicates that the decorated metals significantly strength the interaction. Also, the corresponding SR meaningfully rises to 19.4, 41.0, and 93.4, indicating that by increasing the atomic number of metals, the sensitivity i
... Show MoreIn this work the corrosion behavior of Al metal was studied by using non- destructive testing (NDT), which is a noninvasive technique for determining the integrity of a material. The ultrasonic waves was used to measure the corrosion which occur by two corrosive medium (0.1N sodium chloride and 0.1N sodium hydroxide) and study the corrosion by weight-loss method and electrochemical method in addition to performance the microscopic inspection for the samples before and after the immersion in the corrosive medium. Corrosion parameters were interpreted in these media which involve corrosion potential (Ecorr) and corrosion current density (icorr). The results indicate that both
... Show Moreالمستخلص
يهدف البحث إلى وضع إطار معرفي ومفاهيمي شامل لموضوع البحث, واغناء القارئ والمستفيد بالمعلومات الوافية عنه وتقليص الفجوات المعرفية للمهتمين به وقياس مدى ما هو متوفر وغير متوفر من المتطلبات الأساسية والضرورية لإنشاء صناديق التحوط في البيئة العراقية, وتمثلت صناديق التحوط بالمتغير الرئيس للبحث اما المتغيرات الفرعية فشملت (المتطلبات المالية, المتطلبات البشرية, البيئة التشريعية, الب
... Show MoreObjectives: To determine the (QoL) for patients with permanent pacemaker and to find-out the relationship between
these patients’ (QoL) and their sociodemographic characteristics such as age, gender, level of education, and
occupation.
Methodology: ٨ purposive non-probability” sample of (62) patient with permanent pacemaker was involved in this
study. The developed questionnaire consists of (4) parts which include !.demographic data form, 2.disease-related
information form, 3.socioeconomic data form, and 4.Permanent pacemaker patient’s quality of life questionnaire data
form. The validity and reliability of the questionnaire were determined through the application of a pilot study. ٨
descriptive statistical a
Many problems are facing the installation of piles group in laboratory testing and the errors in results of load and settlement are measured experimentally may be happened due to select inadequate method of installation of piles group. There are three main methods of installation in-flight, pre-jacking and hammering methods. In order to find the correction factor between these methods the laboratory model tests were conducted on small-scale models. The parameters studied were the methods of installation (in-flight, pre-jacking and hammering method), the number of piles and in sandy soil in loose state. The results of experimental work show that the increase in the number of piles value led to increase in load carrying capacity of piled raft
... Show MoreThis research considers the preservation of environment through recycling old toys. This is achieved by transforming the old toys into educational clothing accessories for kindergarten stages. The research methodology adapts both descriptive and applied approaches. The research questionnaire targeted a sample of 35 teachers to collect information about the waste toys in kindergarten. Also, another sample of 30 teachers and mothers were targeted to measure the suitability of the clothing designs for the early childhood stages. The results shows that both teachers and mothers were well satisfied with clothing accessories designed with the toys waste. This concept contributes to limiting the pollution caused by toys and could save time, eff
... Show More