The gamma camera, along with SPECT and PET scanners, is one of the main imaging technologies in nuclear medicine. A collimator is typically constructed from tungsten to provide high absorption of gamma photon energies. It has a hole or holes for imaging. Gamma rays from a radioactive source within the body are emitted in all directions, while the photons required constructing an image travel through the hole. A scintillator is the most common material used to convert the high energy of gamma radiation into a lowenergy optical photon. These detectors are one of the primary secrets to radio-diagnosis in nuclear medicine. The photomultiplier tube (PMT) is a versatile device with extraordinarily highly sensitivity and response. A typical photomultiplier tube contains a photo emissive cathode (photocathode), focusing electrodes, an electron multiplier, and an electron collector (anode). Conclusion: In the medical imaging area, everyone works to improve the resolution, sensitivity, and size of their devices so that patients can be treated better and diagnoses can be made more accurately. Also, the results of this study suggest that HGC could be a potential way to give better support during surgery.
In this paper, Bayes estimators for the shape and scale parameters of Gamma distribution under the Entropy loss function have been obtained, assuming Gamma and Exponential priors for the shape and scale parameters respectively. Moment, Maximum likelihood estimators and Lindley’s approximation have been used effectively in Bayesian estimation. Based on Monte Carlo simulation method, those estimators are compared depending on the mean squared errors (MSE’s). The results show that, the performance of the Bayes estimator under Entropy loss function is better than other estimates in all cases.
In this work, the total linear attenuation coefficients µ(cm
-1
) were calculated and studied
for particulate reinforced polymer-based composites. Unsaturated polyester (UP) resin was
used as a matrix filled with different concentrations of Al, Fe, and Pb metal powders as
reinforcements. The effect of the metal powders addition at different weight percentages in
the range of (10,20,30,40,50)wt % and gamma energy on attenuation coefficients was studied.
The results show, as the metallic particulates content increase, the attenuation coefficients will
increase too, while it, were exhibited a decrease in their values when the gamma energy
increase.The total linear attenuation coefficients of gamma ray fo
The effect of 0.66 µeV gamma radiation on the structural and optical properties of the CdTe thin films prepared by thermal evaporation at thickness 350nm, The samples were irradiated with time (50 h and 79h) at room temperature. The absorption spectra for all the samples were recorded using UV-VIS spectrometer in order to calculate the energy gap, refractive index and others parameter . The optical energy gap was found decrease from (1.9 to 1.67) eV.
In the current work various types of epoxy composites were added to concrete to enhance its effectiveness as a gamma- ray shield. Four epoxy samples of (E/clay/B4C) S1, (E/Mag/B4C) S2, (EPIL) S3 and (Ep) S4 were used in a comparative study of gamma radiation attenuation properties of these shields that calculating using Mont Carlo code (MCNP-5). Adopting Win X-com software and Artificial Neural Network (ANN), µ/ρ revealed great compliance with MCNP-5. By applying (µ/ρ) output for gamma at different energies, HVL, TVL and MFP have been also estimated. ANN technique was simulated to estimate (µ/ρ) and dose rates. According to the results, µ/ρ of all epoxy samples scored higher than standard concrete. Both S2 and S3 samples having h
... Show MoreThe research is concerned about studying the absorption spectrum of the solution coumarin dye C47. The chloroform solvent was used with C47 dye in three different concentrations 10-4, 10-5 and 10-6 M. The laser dye solution was prepared by dissolving the required amount of dye in chloroform alcohol, while studying absorption spectrum before and after irradiation with gamma ray by cobalt-60 source 60Co at exposure time, which are 0, 4, 6 and 18 hours with different absorbed doses 0, 136, 204 and 612 Gy. The results show that red shift in the absorption spectrum was increased by increasing the concentration of laser dye solutions , while the increase of gamma dose led to increase the red shift after irradiation, as the exposure period and irr
... Show MoreBackground:
Visceral Leishmaniasis (VL) is a disseminated protozoan infection caused by Leishmania donovani parasites which affects almost half a million persons annually. Classical diagnosis methods of VL still not very sensitive and time consuming. In this study, we reported the success of polymerase chain reaction (PCR) method to identify L. donovani based on kinetoplast deoxyribonucleic acid (kDNA) for the diagnosis of the parasite using in vitro promastigote cultures. LdI species - specific primer was used to identify L. donovani and the result showed a single band of about ~600bp. It can be recommended that this primer is to be used for detection the visceral L. donovani.
Human cytomegalovirus (CMV) is the globally highly prevalent herpesvirus worldwide. CMV infects populations of all ages according to the Center for Disease Control and Prevention (CDC) and World Health Organization (WHO). CMV infections remain the most common viral complication potentially multiple in humans and are a major cause of congenital normality in women, which is why they are critical for diagnosis in several times when it happens during pregnancy. Pregnant women with CMV infection can be in charge of abortion or congenital expandaedby. This study involves the collection a total of (90) samples taken from each aborted and pregnant woman (70 with abortion cases and 20 of pregnant without history of abortion as control subjects) r
... Show MoreBackground: Ultrasound guided core needle biopsy is becoming a gold standard in the work up of suspicious breast lesion. In Iraq, radiologists are not taking the lead in core needle biopsy performance.
Objectives: To evaluate the radiologist performance of core needle biopsy highlighting the precession and accuracy of the procedure, the concordance of ultrasound and histopathology, and identifying challenges facing the radiologist during the procedure.
Subjects and Methods: A prospective study involving a total of 50 patients with ultrasound (US) BIRADS IV or V. Ultrasound guided core needle biopsy was performed for each patient. Surgical pathol
... Show MoreThis research was designed to study the effect of water and alcoholic crude extracts of Calvatia craniiformis in vitro and in vivo On the other hand this study tested the toxic effect of both extracts in normal laboratory mice. The results showed that water and alcoholic extracts relatively have an acute toxic effect in mice in respect to LD50 (85 mg/kg, and 177mg/kg respectively). However the chronic toxicity of water extract at three different concentration (50, 75, 100 mg/kg) and alcoholic extract at concentrations of (100, 150, 200 mg/kg) was investigated in normal mice by (I.P) administration for 30 days alternatively and one drag in 48 hours . The results indicated significant effect (P ? 0.01) increasing in (MI) and (BI) of bone mar
... Show More