The gamma camera, along with SPECT and PET scanners, is one of the main imaging technologies in nuclear medicine. A collimator is typically constructed from tungsten to provide high absorption of gamma photon energies. It has a hole or holes for imaging. Gamma rays from a radioactive source within the body are emitted in all directions, while the photons required constructing an image travel through the hole. A scintillator is the most common material used to convert the high energy of gamma radiation into a lowenergy optical photon. These detectors are one of the primary secrets to radio-diagnosis in nuclear medicine. The photomultiplier tube (PMT) is a versatile device with extraordinarily highly sensitivity and response. A typical photomultiplier tube contains a photo emissive cathode (photocathode), focusing electrodes, an electron multiplier, and an electron collector (anode). Conclusion: In the medical imaging area, everyone works to improve the resolution, sensitivity, and size of their devices so that patients can be treated better and diagnoses can be made more accurately. Also, the results of this study suggest that HGC could be a potential way to give better support during surgery.
This paper presents a complete design and implementation of a monitoring system for the operation of the three-phase induction motors. This system is built using a personal computer and two types of sensors (current, vibration) to detect some of the mechanical faults that may occur in the motor. The study and examination of several types of faults including (ball bearing and shaft misalignment faults) have been done through the extraction of fault data by using fast Fourier transform (FFT) technique. Results showed that the motor current signature analysis (MCSA) technique, and measurement of vibration technique have high possibility in the detection and diagnosis of most mechanical faults with high accuracy. Subsequently, diagnosi
... Show MoreBackground: The critically ill patient is at risk of developing intensive care acquired infection, with the lungs being especially vulnerable. Ventilator associated pneumonia (VAP) occurring after two days of mechanical ventilation and it is the most nosocomial infection seen in the intensive care unit .The establishment of an accurate diagnosis of ventilator associated pneumonia remains problematic and yet there is still no accepted "gold standard" for the diagnosis.
Patients& Methods: This is a cross section study for 328 patients admitted to intensive care unit at medical city teaching hospital. Full history, physical examination and investigation were done after 48 hours of admission according to
In this paper, the optical emission spectrum (OES) technique was used to analyze the spectrum resulting from the (CdO:CoO) plasma in air, produced by Nd:YAG laser with λ=1064 nm, τ=10 ns, a focal length of 10 cm, and a range of energy of 200-500 mJ. We identified laser-induced plasma parameters such as electron temperature (Te) using Boltzmann plot method, density of electron (ne), length of Debye (λD), frequency of plasma (fp), and number of Debye (ND), using two-Line-Ratio method. At a mixing ratio of X= 0.5, the (CdO:CoO) plasma spectrum was recorded for different energies. The results of plasma parameters caused by laser showed that, with t
... Show MoreA factorial experiment (2× 3) in randomized complete block design (RCBD) with three replications was conducted to examine the effect of honeycomb selection method using three interplant distances on yield and its components of two cultivars of bean, Bronco and Strike. Interplant distances used were 75× 65 cm, 90× 78 cm, and 105× 91 cm (row× plant) represent short (high plant density), intermediate (intermediate plant density), and wide (low plant density) distance, respectively. Parameters used for selection were number of days from planting to the initiation of first flower, number of nodes formed prior to first flower, and number of main branches. Results showed significant superiority of the Bronco cultivar represented in the number
... Show MoreIn the present study the radon concentration was measured in indoor places by the RAD7 (radon detector) was in some locations at Al-Tuwaitha nuclear site and some surrounding areas for the duration from 13/10/2016 to 2/1/2017 and the measurement of the indoor radon concentration ranged from (4.96±4.4 to 102±25) Bq/m3. The high value of radon has been found at decommissioning directorate /emergency room, which is lower than the action value recommended by the Environmental Protection Agency (EPA) which is (148 Bq/m3) while the lowest value has been founded in central laboratories directorate \ models room. These values were used to calculate the annual effective dose and the health risks for cells bronchial which caused by the inhalatio
... Show MoreThe analysis of Iraqi light oil (light naphtha) by capillary gas chromatography- mass spectrometry (GC-MS) was performed by the injection of whole naphtha sample without use of solvents. Qualitative analysis and the identification of the hydrocarbon constituents of light naphtha was performed and comparison had been done with American light oil (light naphtha). The obtained results showed a major difference between the two-light naphtha.
We define skew matrix gamma ring and describe the constitution of Jordan left centralizers and derivations on skew matrix gamma ring on a -ring. We also show the properties of these concepts.
Background: Urine cytology has an acceptable sensitivity, & specificity that justifies its use in the current diagnostic protocol. In Iraq transitional cell carcinoma (TCC) constitute about 62.1 % of bladder cancer (which ranks the third according to the results of Iraqi Cancer Registry 1995-1997). Urine cytology used in the primary diagnosis, follow up, and in the screening programs of asymptomatic but high-risk patients.
Patients and methods: This study was conducted on 93 patients, diagnosed or clinically suspected to have TCC of the urinary bladder attending to the Urological department in ALKadhimiya Teaching Hospital, AL-Yarmouk Teaching Hospital, and Baghdad Medical City. During the p
Article information: COVID-19 has roused the scientic community, prompting calls for immediate solutions to avoid the infection or at least reduce the virus's spread. Despite the availability of several licensed vaccinations to boost human immunity against the disease, various mutated strains of the virus continue to emerge, posing a danger to the vaccine's ecacy against new mutations. As a result, the importance of the early detection of COVID-19 infection becomes evident. Cough is a prevalent symptom in all COVID-19 mutations. Unfortunately, coughing can be a symptom of various of diseases, including pneumonia and inuenza. Thus, identifying the coughing behavior might help clinicians diagnose the COVID-19 infection earlier and distinguish
... Show MoreBackground: The incidence of maternal mortality in
placenta previa accrete is 7%,and its preoperative
diagnosis is of a great value.
Objective: to evaluate the efficacy of transabdominal
color Doppler ultrasound in diagnosing placenta
previa accreta and inccreta. Color Doppler imaging
criteria used in: includes diffuse parenchymal
placental lacunar flow, focal intra parenchymal
placental lacunar flow and bladder uterine serosa
interphase hyper-vascularity.
Design: Prospective study on patients from
January2007 to January 2008.
Patients and method: 48patients with one caesarean
section or more and with persistent anterior placenta
previa diagnosed by transabdominal ultrasound were
examined by c