In this study used three methods such as Williamson-hall, size-strain Plot, and Halder-Wagner to analysis x-ray diffraction lines to determine the crystallite size and the lattice strain of the nickel oxide nanoparticles and then compare the results of these methods with two other methods. The results were calculated for each of these methods to the crystallite size are (0.42554) nm, (1.04462) nm, and (3.60880) nm, and lattice strain are (0.56603), (1.11978), and (0.64606) respectively were compared with the result of Scherrer method (0.29598) nm,(0.34245),and the Modified Scherrer (0.97497). The difference in calculated results Observed for each of these methods in this study.
In this research, the X-ray diffraction pattern was used, which was obtained experimentally after preparation of barium oxide powder. A program was used to analyze the X-ray diffraction lines of barium oxide nanoparticles, and then the particle size was calculated by using the Williamson-Hall method, where it was found that the value of the particle size is 25.356 nm. Also, the dislocation density was calculated, which is equal to1.555 x1015 (lines/nm2), and the value of the unit cell number was also calculated, as it is equal to 23831.
People who undertaken different X-ray examinations are already exposed to ionizing radiation which causes biological effects. Therefore assessing the patient radiation dose is a prerequisite element in optimizing the X-ray practice and to avoid the unnecessary radiation dose. The aim of this research is to assess the skin radiation dose for those patients who undertaking routine X-ray examinations in selected three hospitals in Al Najaf city.
Three X-ray units were involved in this experimental study; these were belonging to three hospitals in Al Najaf city-Iraq, namely Al-Sadder teaching hospital, Al-Hakeem general hospital and Al-Zahraa hospital. Data of exposure parameters (tube potential (kVp), tube c
... Show MoreBackground: The use of the chest x-ray measurements which includes the cardiothoracic ratio(C-T) and frontal area (FA) of the heart by the CXR are useful measures for primary assessment of the cardiac dysfunction.
Patients and Methods: A Prospective study was done from the 1st of January 2005 to the 1st of October in the same year on a 120 consecutive patients who have been admitted for coronary and L.V angiogram at IBN-AL-BITAR hospital. The C-T ratio and the frontal area were measured.
Results: The study comprised 120 subjects who were admitted for coronary and L.V angiogram for diagnostic reasons. 89subjects (74.2%) are male and 31subjects (25.8%) are female .17(14%) subjects have left ventricular d
Different bremsstrahlung spectra from tungsten anode x-ray tube generated at 30, 40 and 50 kV have been examined theoretically and experimentally for an attempt to find a most suitable spectrum to radiograph a test object of 0.01 cm thickness of Cu and Ag. The high contrast using this suitable spectrum is demonstrated and the possible effects of fluorescent radiation are discussed.
In this research, the Williamson-Hall method and of size-strain plot method was employed to analyze X- ray lines for evaluating the crystallite size and lattice strain and of cadmium oxide nanoparticles. the crystallite size value is (15.2 nm) and (93.1 nm) and lattice strain (4.2 x10−4 ) and (21x10−4) respectively. Also, other methods have been employed to evaluate the crystallite size. The current methods are (Sherrer and modified Sherrer methods ) and their results are (14.8 nm) and (13.9nm) respectively. Each method of analysis has a different result because the alteration in the crystallite size and lattice strain calculated according to the Williamson-Hall and size-strain plot methods shows that the non-uniform strain in nan
... Show MoreMedical images play a crucial role in the classification of various diseases and conditions. One of the imaging modalities is X-rays which provide valuable visual information that helps in the identification and characterization of various medical conditions. Chest radiograph (CXR) images have long been used to examine and monitor numerous lung disorders, such as tuberculosis, pneumonia, atelectasis, and hernia. COVID-19 detection can be accomplished using CXR images as well. COVID-19, a virus that causes infections in the lungs and the airways of the upper respiratory tract, was first discovered in 2019 in Wuhan Province, China, and has since been thought to cause substantial airway damage, badly impacting the lungs of affected persons.
... Show MoreBackground: The bone mineral density of the lumbar vertebra has been assessed according to the results of the Dual-Energy X-Ray Absorptiometry (DEXA). Although anemia is known to affect bone mineral density, at the present time, it is not clear which vertebra is more affected by this disease. Objective: To evaluate the effects of anemia on the bone mineral density of the lumbar vertebra in comparison with a normal subject and determine which part of the lumbar vertebra is more affected by anemia. Methods: All 205 participants in this study complained of bone pain (90 males and 105 females). 95 patients, including both sexes, suffered from anemia. Additionally, the study included 110 seemingly healthy volunteers as the control group
... Show MoreThe concentration of elements were analyzed of twelve cultivation medium (Peat moss, Perlite and Hermon) selected from Iraqi markets using X-ray fluorescence techniques. The analytical results show that the cultivation medium contained high concentration of (Na, Al, Si, S, K, Ca, Fe) and low concentration of (Mg, P, Cl, Ti, V, Cr, Mn, Co, Ni, Cu, Zn). The samples also contained trace concentration of (Ge, As, Se, Br, Sr, Y, Mo, Cd, I, Hg, Pb, U). The results were compared using atomic absorption spectrophotometric technique for measuring the concentration of (K, Ca, Cu, Mn, Zn, Pb).
The Results showed that there is significant difference in the concentration of each element in most of the samples. The concentrations of elements a
... Show MoreX-rays fluorescence technology was used to measure the concentrations of trace and toxic elements in tobacco smoke. One sample local and eight samples were imported selected from Iraqi markets. The results proved that tobaccos contain few concentrations of element (calcium, potassium, sodium, manganese, magnesium, chlorine, and sulfur), trace concentrations of element (aluminum, vanadium, iron, cobalt, nickel, copper and zinc), and toxic concentrations of element (arsenic, selenium, bromine, antimony, cadmium, mercury and lead). Results are proved the concentrations of elements of samples are lower levels with the other countries in few element like (calcium, potassium, sodium and manganese), while the other elements were hi
... Show More