In this research, we introduce and study the concept of fibrewise bitopological spaces. We generalize some fundamental results from fibrewise topology into fibrewise bitopological space. We also introduce the concepts of fibrewise closed bitopological spaces,(resp., open, locally sliceable and locally sectionable). We state and prove several propositions concerning with these concepts. On the other hand, we extend separation axioms of ordinary bitopology into fibrewise setting. The separation axioms we extend are called fibrewise pairwise T_0 spaces, fibrewise pairwise T_1 spaces, fibrewise pairwise R_0 spaces, fibrewise pairwise Hausdorff spaces, fibrewise pairwise functionally Hausdorff spaces, fibrewise pairwise regular spaces, fibrewise
... Show MoreFructophilic lactic acid bacteria (FLAB) isolated from honeybee’s nectar stomach represent an important source of antimicrobial substances that has been focused on nowadays. In this study, these FLABs were tested for their antibacterial activity in vivo as well as the detection of Interleukine -17 in the serum of rabbits ingested with FLAB isolates. Fructobacillus fructosus FH1, Fructobacillus fructosus FH8 and Lactobacillus kunkeei SHGH-7 FLAB isolates were used against wound infections caused by Pseudomonas aeruginosa and Staphylococcus aureus (MRSA) in rabbit skin . Enzyme linked sorbent immunoassay (ELISA) was used to detect the levels of Interleukine-17 in the sera of rabb
... Show MoreSource, sedimentation, coagulation, flocculation, filter, and tank are parts of a water treatment plant. As a result, some issues threaten the process and affect the drinking water quality, which is required to provide clean drinking water according to special standards and international and local specifications, determined by laboratory results from physical, chemical, and biological tests. In order to keep the water safe for drinking, it is necessary to analyze the risks and assess the pollution that occurs in every part of the plant. The method is carried out in a common way, which is monitoring through laboratory tests, and it is among the standards of the global and local health regulators
Source, sedimentation, coagulation, flocculation, filter, and tank are parts of a water treatment plant. As a result, some issues threaten the process and affect the drinking water quality, which is required to provide clean drinking water according to special standards and international and local specifications, determined by laboratory results from physical, chemical, and biological tests. In order to keep the water safe for drinking, it is necessary to analyze the risks and assess the pollution that occurs in every part of the plant. The method is carried out in a common way, which is monitoring through laboratory tests, and it is among the standards of the global and local health regulators
Pseudomonas aerogenosa lipopolysaccharidewas extracted by hot phenol method and purified by gel filtration method using the Sephadex G-200 gel and detected by the limulus amebocyt lysate (EU/ml 0.03)(Wako Chemicals USA, Inc.). The inhibitory effect of partially purified LPS on Candida glabrata yeast was studied in a microdilution method. This study found that LPS has an inhibitory effect on Candida glabrata with the lower concentrations. The inhibitory effect of LPS which treated with heating was studied under boiling and wet heat effect. The toxicity of LPS on Candida glabrata was not affected when treated with heating LPS and the results were similar to those found in untreated LPS
Background: Neonatal septicemia is a major health problem in developing countries furthermore data on bacteriological profile in early onst sepses (EOS) and late neonatal sepsis (LOS) are lacking in context of continuous change in bacteriological profile and increasing resistant strains. Objectives: The study done to determine the pattern of organisms implicated in neonatal septicemia in a neonatal care unit and to measure the degree of bacterial resistance to some antibiotics.
Type of the study : cross –sectional study.
Methods: Confirmed cases of neonatal septicemia admitted at Al-Alwyia pediatric teaching hospital for the period from January 20
... Show MoreABSTRACT
Metal (II) complexes of Co, Ni, Cu and Zn with cefdinir C14H13N5O5S2 derivative (L) were synthesized and identification by elemental analysis CHNS Uv-Vis, FTIR, TGA, metal analysis AA, magnetic susceptibility and conduct metric measurement. by analysis the ligand behaves as a bidentate. For the cobalt complex, Tetrahedral geometry shape was suggested, while other complexes that have nickel, copper and zinc ions were proposed as octahedral geometry shape. The experimental method was studied for prevention of corrosion carbon steel in 3.5% NaCl by using a novel Cefdinir derivations drugs. The results showed that metal complex was a strong corro
... Show MoreCinnamon plant is considered one of important medicinal plants because it is rich with many active compounds. This research is aimed to study possible effects of extract in culture media of Gardenia jasmenoides. Alcoholic extract was prepared from the bark of cinnamon at different concentrations (0.0, 1.0, 2.0) mg/L, then added to culture media to notice the effect of these concentrations on the growth and development of tissues and organs of Gardenia jasmenoides Ellis in vitro. Results showed the positive effect of increasing callus fresh weight and shoot proliferation from single nodes with presence of plant regulators, 5.0 mg/L Naphthalene acetic acid (NAA) and 3.0 mg/L Benzyl adenine (BA). Results showed that extract has a slight eff
... Show MoreIndustrial characteristics calculations concentrated on the physical properties for break down voltage in sf6, cf4 gases and their mixture with different concentrations are presented in our work. Calculations are achieved by using an improved modern code simulated on windows technique. Our results give rise to a compatible agreement with the other experimental published data.
Al-Rustamiya sewage treatment plant (WWTP) serves the east side of Baghdad city (Rusafa) and is considered one of the largest projects.It consists of three parts (old project F0, first extension F1, and second extension F2) that treat wastewater and the
effluent is discharged into Diyala river and thus into the Tigris River. These plants are designed and constructed with an aim to manage wastewater to reachIraqi effluent standard for BOD5, COD, TSS and chloride concentrations of 40, 100, 60 and 600
mg/L respectively. The data recordedfrom March till December 2011 provided from Al-RustamiyaWWTP, were considered in this study to evaluate the performance of the plant. The results indicated that the strength of the wastewater enterin