This research deals with the risks of non-compliance and its impact on the profitability of Islamic banks. Research variables were measured and analyzed as the risk of non-compliance as an independent variableand profitability as a dependent variable. The profitability was measured by three indicators ((rate of return on assets, rate of return on equity and rate of return on Total deposits)) The results of the research showed a significant relationship between the risk of non-compliance and the rate of return on assets and rate of return on total deposits, while there was no relationship between the risk of non-compliance and rate of return on ownership. The research recommended that the senior management of the Islamic Investment Bank should work to find the appropriate outlets to enhance the banking return by attracting bank deposits and directing investments towards investment channels that are compatible with the nature of Islamic banking work and working in the light of a moderate balance between liquidity, profitability and safety, On the competitive role of the bank with other competitors.
This study investigates the surgical and thermal effects on oral soft tissues produced by CO2 laser emitting at 10.6 micrometers with three different fluences 490.79, 1226.99 and 1840.4 J/cm2. These effects are specifically; incision depth, incision width and the tissue damage width and depth. The results showed that increasing the fluence and /or the number of beam passes increase the average depths of ablation. Moreover, increasing the fluence and the number of beam passes increase the adjacent tissue damage in width and depth. Surgeons using CO2 laser should avoid multiple pulses of the laser beam over the same area, to avoid unintentional tissue damage.
Background: pulmonary function can change with age for normal individual's .Spirometric measurement for the ratio of forced expiratory volume in one second (FEV1), the forced vital capacity and the ratio (FEV1/FVC) can reveal airway obstruction and the consequence change in pulmonary performance. These parameters can be different for different race /ethnic and gender.
Methods: Pulmonary function test were carried out on 29normal male and 37 normal female the test parameters were FEV1 and FVC from which the ratio of FEV1/FVC %was calculated in relation to age. Iraqi average for FEV1 and FVC and FEV1/FVC % has also been obtained
Results: results of these tests reveled that the ratio of FEV1/FVC % is almost th
Background: Treatment of malocclusions using removable orthodontic appliances may prepare new stagnant areas susceptible for colonization and retention of Candida species, therefore; the aim of this study was to investigate the effect of upper removable orthodontic appliances on the mucosal Candidal count in group of apparently healthy orthodontic patients. Materials and Methods: Patients enrolled in this study were children aged 8-12 years having upper removable orthodontic appliances. Candidal counts at six mucosal sites were estimated using Imprint Culture method before, 14 and 28 days during orthodontic therapy. Results: Whole mouth and individual mucosal sites for Candidal counts increase significantly during treatment with upper remov
... Show MoreElectrospun nanofiber membranes are employed in a variety of applications due to its unique features. the nanofibers' characterizations are effected by the polymer solution. The used solvent for dissolving the polymer powder is critical in preparing the precursor solution. In this paper, the Polyacrylonitrile (PAN)-based nanofibers were prepared in a concentration of 10 wt.% using various solvents (NMP, DMF, and DMSO). The surface morphology, porosity, and the mechanical strength of the three prepared 10 wt.% PAN-based nanofibers membranes (PAN/NMP, PAN/DMF, and PAN/DMSO) were characterized using the Scanning Electron Microscopy (SEM), Dry-wet Weights method, and Dynamic Mechanical Analyzer (DMA). Using DMF as a solvent resulted in a lon
... Show MoreIn this paper, the effect of wear in the fluid film journal bearings on the dynamic behavior of rotor bearing system has been studied depending on the analytical driven of dynamic stiffness and damping coefficients of worn journal bearing. The finite element method was used to modeling rotor bearing system. The unbalance response, critical speed and natural frequency of rotor bearing system have been studied to determine the changes in these parameters due to wear. MATLAB software was used to find the analytical values of dynamic coefficients of journal bearing. The results of rotor mounted on fluid film journal bearings showed that the wear in journal bearing increases the amplitude of unbalance response and decrease critical speed, sta
... Show MoreThe fatigue is one of the major reasons for fracture of materials. Aluminum 7204 AA alloy with various heat treatments and (2.0) wt % of SiC nanoparticles were prepared by stir-casting method under rotating bending loading with ratio of stress (R= -1). The composite was strengthened by SiC particles size of) 10 (nanometre. The fatigue strength and life were obtained experimentally by the family of S-N curves for different heat treatments. The endurance limits (107cycles) for 7204 AA/ 2.0wt% SiC nano-composite fatigue strength as related to untreated nanocomposite was enhanced by 72 and 78.5% for T4 and T6, respectively.The improvement 
... Show MoreThis contribution investigates structural, electronic, and optical properties of cubic barium titanate (BaTiO3) perovskites using first-principles calculations of density functional theory (DFT). Generalized gradient approximations (GGA) alongside with PW91 functional have been implemented for the exchange–correlation potential. The obtained results display that BaTiO3 exhibits a band gap of 3.21 eV which agrees well with the previously experimental and theoretical literature. Interestingly, our results explore that when replacing Pd atom with Ba and Ti atoms at 0.125 content a clear decrease in the electronic band gap of 1.052 and 1.090 eV located within the visible range of electromagnetic wavelengths (EMW). Optical parameters such as a
... Show MoreBackground: Left ventricular function and volumes have major diagnostic and prognostic importance in patients with various cardiac diseases, such as ischemic heart disease which is a life-threatening heart disease condition characterized by systolic dysfunction and a decrease in cardiac output.
According to left ventricular ejection fraction, the degree of ischemic heart disease was classified as mild, moderate, and severe. To determine cardiac function and hemodynamics, the echocardiography technique is used, which is a noninvasive diagnostic method.
Patients and Methods: The study included 216 patients between 25 and 75 years old; 121 males and 95 females; 265 normal individuals (age range: 25 to 75 years ol
... Show MoreNinety eight specimens were collected from patients referring different hospitals in Baghdad in period from August to November in 2012. Specimens including (swabs from (Sputum, burn, wound, urine, ear, and eye).Sixty six isolates were identified as Pseudomonas aeruginosa. The isolates were identified according to morphological, cultural, biochemical characteristics and API 20E test. 90% of P. aeruginosa isolates produced pyocyanin pigment on King A medium in different amounts, whereas other isolates were produced other types of pigments such as (pyoverdine-yellow, pyorubin-red, and pyomelanin-black) on King B medium and also in different amounts.Quantitative assay of pyocyanin production was conducted. The results were shown that the iso
... Show More