Preferred Language
Articles
/
Bxe-Yo8BVTCNdQwC7XV9
The effect of left ventricle ischemia severity on cardiac performance appeared on ejection fraction using radioactive TC <sup>99m</sup> MIBI in comparison with echocardiography
...Show More Authors
Abstract<p>Ischemic heart disease is a major causes of heart failure. Heart failure patients have predominantly left ventricular dysfunction (systolic or diastolic dysfunction, or both). Acute heart failure is most commonly caused by reduced myocardial contractility, and increased LV stiffness. We performed echocardiography and gated SPECT with Tc<sup>99m</sup> MIBI within 263 patients and 166 normal individuals. Left ventricular end systolic volume (LVESV), left ventricular end diastolic volume (LVEDV), and left ventricular ejection fraction (LVEF) were measured. For all degrees of ischemia, there was a significant difference between ejection fraction values measured by SPECT and echocardiography, and there were no significant differences among end systolic volume and end diastolic volume value calculated by two methods for all cases.</p><p>The mean value for EDV (ECHO)/EDV (SPECT) was 1.07 ± 0.31 for degree (1, 2); in the degree 3 the mean value was 1.02 ± 0.08, and 1.005 ± 0.07 for degree 4.</p><p>The mean value for ESV (ECHO)/ESV (SPECT) was 1.08 ± 0.34 for degree (1, 2); while 1.03 ± 0.12, 1.021 ± 0.128 for degree 3 and 4 respectively.</p><p>This study was showed a good relation between left ventricular size and ejection fraction measured by SPECT with Tc<sup>99m</sup>, and echocardiography.</p>
Scopus Crossref
View Publication
Publication Date
Tue Nov 30 2021
Journal Name
Iraqi Journal Of Science
Evaluation of Left Ventricle Performance in Patients with Ischemic Heart Disease Using Single Photon Emission Computed Tomography (SPECT) in Comparison with Echocardiography
...Show More Authors

Background: Ischemic heart disease is a major cause of the diastolic heart failure. Risk of heart failures was increased with microvascular coronary disease, which is characterized by left ventricular stiffness  with impaired relaxation and reduced compliance. Aim of this study is to estimate the effect of the severity of myocardium ischemia on the left ventricle ejection fraction and left ventricular volume using SPECT with 99mTc MIBI and to compare the results  with the echocardiography. The study included 117 subjects with ischemic heart disease were examined using SPECT and echocardiography techniques. The following

... Show More
View Publication Preview PDF
Crossref (1)
Scopus Crossref
Publication Date
Mon Jul 01 2013
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Left Ventricle Remodeling for Patients with Heart Failure and its Influence on Cardiac Performance
...Show More Authors

Background: Many cardiac diseases can cause cardiac hypertrophy developed by the established cardiac overload, such as long term of uncontrolled hypertension, valvuler disease or congenital anomaly and many more causes. If the cause of hypertrophy persists for long time it will generate heart failure, as a result changes in size, shape and function of the heart which refer as remodeling.
Objective: To investigate the types of remodeling in patients with heart failure, and study its relation with cardiac performance.
Patients and methods: The study included fifty normal individuals and fifty patients, only those patients who developed hypertrophy and failure were chosen. The study has included the measurements of many cardiac parame

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Dec 30 2015
Journal Name
Al-kindy College Medical Journal
Estimation Of Left Ventricular Ejection Fraction Using Mitral Annular Displacement Derived By Speckle Tracking Echocardiography In Patients With Different Heart Diseases
...Show More Authors

Background: Speckle tracking echocardiography (STE)-derived mitral annular displacement (MAD) utilizes the speckle tracking technique to measure strain vectors, which provides accurate estimates of left ventricular ejection fraction (LVEF).Objectives: To validate the accuracy of mitral annular displacement (MAD), assessed by Speckle Tracking Echocardiography (STE), as a surrogate for determination of left ventricular systolic function in comparison to 2-Dimensions Simpson method in patients with different heart diseases.Methods : This cross-sectional study included patients who referred to outpatient department of Ibn Albitar Center for Cardiac Surgery, Baghdad, Iraq, between October 2012 and April 2013. STE continuously tracked annular

... Show More
View Publication Preview PDF
Publication Date
Sat Sep 01 2012
Journal Name
Australian Journal Of Basic And Applied Sciences
Electrochemical interferences of Mn<sup>2+</sup> with Hg<sup>2+</sup>, Cd<sup>2+</sup> and Cu<sup>2+</sup> at different modified GCE
...Show More Authors

Glassy carbon electrode (GCE) was modified with carbon nanotubes CNT and C60 by attachment and solution evaporation techniques, respectively. CNT/Li+/GCE and C60/Li+/GCE were prepared by modifying CNT/GCE and C60/GCE in Li+ solution via cyclic voltammetry (CV) potential cycling. The sensing characteristics of the modified film electrodes, demonstrated in this study for interference of Mn2+ in different heavy metals ion esp. Hg2+, Cd2+ and Cu2+. The interfering effect was investigated that exert positive interference on the redox peaks of Mn2+. The modification of GCE with nano materials and Li+ act an enhancement for the redox current peaks to observe the effect of interference for Mn2+ in 1:1 ratio with different heavy metals ion.

Scopus (3)
Scopus
Publication Date
Mon Jan 01 2024
Journal Name
Journal Of Oral Medicine And Oral Surgery
Evaluating dental implant stability using three devices Osstell<sup>®</sup>, Periotest<sup>®</sup>, and AnyCheck<sup>®</sup>: a clinical study
...Show More Authors

Introduction: Implant stability is usually measured with resonance frequency analysis (RFA) and damping capacity assessment (DCA). This study aimed to measure primary and secondary stabilities using 3 devices that are based on these methods, namely; RFA (Osstell®) and DCA (Periotest® and AnyCheck®) to assess the correlations of the measurements obtained by these devices and the correlations between implant stability and insertion torque. Material and Methods: This observational prospective study included 35 dental implants. The implant stability was measured using the 3 devices. Mann–Whitney U

... Show More
View Publication
Crossref
Publication Date
Thu Apr 08 2021
Journal Name
Journal Of Interdisciplinary Mathematics
The F-composition operator on Hardy space ℍ<sup>2</sup>
...Show More Authors

View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Fri May 01 2020
Journal Name
Journal Of Physics: Conference Series
The Product of Automorphic Weighted Composition Operators on Hardy Space H <sup>2</sup>
...Show More Authors
Abstract<p>Let <inline-formula> <tex-math><?CDATA $n\in {\mathbb{N}},{p}_{i}\in {\rm{U}},{\alpha }_{{P}_{i}}(z)=\frac{{p}_{i}-z}{1-{\bar{p}}_{i}z}(z\in {\rm{U}})$?></tex-math> <math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mrow> <mi>n</mi> <mo>∈</mo> <mi>ℕ</mi> <mo>,</mo> <msub> <mi>p</mi> <mi>i</mi> </msub></mrow></math></inline-formula></p> ... Show More
View Publication
Scopus Crossref
Publication Date
Sun Apr 01 2012
Journal Name
2012 International Conference On Future Communication Networks
Efficient method to find the multiplicative inverse in GF (2&lt;sup&gt;m&lt;/sup&gt;) using FPGA by exponentiation to (2&lt;sup&gt;k&lt;/sup&gt;)
...Show More Authors

Crossref (1)
Crossref
Publication Date
Sun Apr 01 2012
Journal Name
2012 International Conference On Future Communication Networks
Efficient method to find the multiplicative inverse in GF (2&lt;sup&gt;m&lt;/sup&gt;) using FPGA by exponentiation to (2&lt;sup&gt;k&lt;/sup&gt;)
...Show More Authors

Multiplicative inverse in GF (2 m ) is a complex step in some important application such as Elliptic Curve Cryptography (ECC) and other applications. It operates by multiplying and squaring operation depending on the number of bits (m) in the field GF (2 m ). In this paper, a fast method is suggested to find inversion in GF (2 m ) using FPGA by reducing the number of multiplication operations in the Fermat's Theorem and transferring the squaring into a fast method to find exponentiation to (2 k ). In the proposed algorithm, the multiplicative inverse in GF(2 m ) is achieved by number of multiplications depending on log 2 (m) and each exponentiation is operates in a single clock cycle by generating a reduction matrix for high power of two ex

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Mon Mar 01 2021
Journal Name
World Heart Journal
Change in Left Ventricular Size and Ejection Fraction in Patients at Rest vs. Stress with Different Degrees of Ischemic Heart Failure
...Show More Authors

Background and Aim. Coronary artery disease (CAD) is a major risk factor for the progression to heart failure (HF), which is associated with an increase in left ventricular volume (LVV). This study aims to measure ventricular function and myocardial perfusion imaging markers of the left side of the heart, which can be performed with injection of a 99mTc at stress and rest by using single-photonemission-computed-tomography (SPECT). Subject and methods. The study included 121 patients with CAD, comprising 53 females and 68 males with ages between 25 to 88 years and 265 healthy subjects comprising 84 males and 181 females. All patients and healthy subjects volunteered to participate in this study. They were classified according to

... Show More