Preferred Language
Articles
/
joe-800
Flow Characteristics Of Tigris River Within Baghdad City During Drought
...Show More Authors

The main source of water supply in Iraq is the surface water, especially Tigris and Euphrates Rivers and their tributaries. In the recent years there was a great drop in the water levels of Tigris River within Baghdad City which had affected the operation of twelve water supply projects located on the banks of Tigris River in Baghdad City, due to significant climate changes, and the expansion of hydraulic construction (dams) and implementation of new irrigation projects in Turkey, these factors have greatly reduced the water flowrates of river by about 46%. In the present study the flow characteristics of Tigris River within Baghdad City was studied, the reach involved was about 49km in which it represents the urban zone beginning from the north of the Baghdad City at Al-Muthana Bridge to the confluence of Tigris River with the Diyala River south of Baghdad, using steady flow one-dimensional hydraulic model to achieve raising of water levels within this reach during drought periods. This model was implemented using HEC-RAS software.Three sets of observation data were used to calibrate the model to estimate suitable Manning roughness coefficient (n) considering the root mean square error (RSME) as an accurate indicator. The results showed that n of value 0.032 for the main river bed and 0.040 for flood banks of the river gave the best results with minimum RMSE of 0.076. Several treatments were suggested such as construction of barrage, inflatable weir, and the use of obstruction for the purpose of raising water levels. Moreover, selection of the suitable site of these treatments or hydraulic structures was studied, as well as their cost was analyzed. The results show that the proper solution for maintain the required water levels that ensure continuous operation of water supply project was the construction of an inflatable weirs, due to low initial cost, simplicity of operation, their ability to inflate and deflate quickly and easily to prevent upstream flooding, and offering a high level of control and easy method for recapturing water.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Mar 01 2021
Journal Name
Iraqi Journal Of Physics
Studying of Plasma- Polymerized Pyrrole at Variable Gas Flow Rates Via Plasma Jet
...Show More Authors

     In this manuscript has investigated the synthesis of plasma-polymerized pyrrole (C4H5N) nano-particles prepared by the proposed atmospheric pressure nonequilibrium plasma jet through the parametric studies, particularly gas flow rate (0.5, 1 and 1.5 L/min). The plasma jet which used operates with alternating voltage 7.5kv and frequency 28kHz. The plasma-flow characteristics were investigated based on optical emission spectroscopy (OES). UV-Vis spectroscopy was used to characterize the  oxidization  state for polypyrrole. The major absorption appears around 464.1, 449.7 and 435.3  nm at the three flow rate of argon gas. The chemical composition and structural properties of the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jan 01 2024
Journal Name
2nd International Conference For Engineering Sciences And Information Technology (esit 2022): Esit2022 Conference Proceedings
Spectroscopic study of dielectric barrier discharge argon plasma at different gas flow rates
...Show More Authors

Dielectric barrier discharges (DBD) can be described as the presence of contact with the discharge of one or more insulating layers located between two cylindrical or flat electrodes connected to an AC/pulse dc power supply. In this work, the properties of the plasma generated by dielectric barrier discharge (DBD) system without and with a glass insulator were studied. The plasma was generated at a constant voltage of 4 kV and fixed distance between the electrodes of 5 mm, and with a variable flow rate of argon gas (0.5, 1, 1.5, 2 and 2.5) L/min. The emission spectra of the DBD plasmas at different flow rates of argon gas have been recorded. Boltzmann plot method was used to calculate the plasma electron temperature (Te), and Stark broadeni

... Show More
View Publication
Scopus Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Steady and unsteady flow of non-newtonian fluid in curved pipe with triangular
...Show More Authors

This paper deals with numerical study of the flow of stable and fluid Allamstqr Aniotina in an area surrounded by a right-angled triangle has touched particularly valuable secondary flow cross section resulting from the pressure gradient In the first case was analyzed stable flow where he found that the equations of motion that describe the movement of the fluid

View Publication Preview PDF
Publication Date
Sat Feb 05 2011
Journal Name
International Journal Of Chemical Reactor Engineering
Mass Transport Properties of a Flow-Through Electrolytic Reactor Using Zinc Reduction System
...Show More Authors

An electrolytic process for the removal of Zn(II) from aqueous solution using a parallel amalgamated copper screens cathode operated in the flow through mode is proposed. The current-potential curves recorded at a rotating amalgamated copper disc electrode were used to determine diffusion coefficient of Zn(II). The performance of electrolytic reactor was investigated by using different flow rates at initial zinc ion concentration(48 mg/L). Taking into account the residential Zn(II) concentration, the best results were obtained for cathode potential of (-1.35 V vs. SCE) at flow rate (320 L/h). Zinc ion concentration was found to decrease from 48 mg/L to 1 mg/L during 120 min. of electrolysis. The experimental data are well correlate

... Show More
View Publication
Crossref
Publication Date
Sun Jun 07 2015
Journal Name
Baghdad Science Journal
Flow Injection Spectrophotometric Determination of Thymol using 4-Aminoantipyrine and Copper(II) Nitrate
...Show More Authors

Flow-injection (FI) spectrophotometric method has been developed for the analysis of thymol in pharmaceutical preparations. The method is based on organic coupling reaction between thymol and 4-amino antipyrine in the presence of alkaline medium to form an intense stable red color complex with copper nitrate that has a maximum absorption at 490 nm. Optimum conditions for determination of the drug was investigated .The calibration graph was linear over the range of 5-500 µg.ml-1 of thymol . The limit of detection (LOD) and limit of quantification (LOQ) were 1.81 ?g mL-1 and 3.60 ?g mL-1 respectively .The proposed method was applied satisfactorily to the determination of thymol in mouth wash preparations. The procedure is characterized by

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat May 08 2021
Journal Name
Social Science And Humanities Journal
The impact of accounting for material flow costs in reducing costs: Exploratory study
...Show More Authors

Rapid and continuous developments and changes in the modern business environment in all areas of economic, environmental, social, technology and communications push economic units to search for modern methods and methodologies to produce products at low cost as well as produce products that meet the wishes of customers in terms of quality and environment to maintain their market position, and accounting for the costs of the flow of materials is one of the most prominent environmental management accounting techniques capable of providing information to help produce

Preview PDF
Publication Date
Sun Dec 02 2012
Journal Name
Baghdad Science Journal
Unsteady Magnetohydrodynamics oscillating flow of third order fluid with central free stream velocity
...Show More Authors

In this article the unsteady magnetohydrodynamics oscillating flow of third order fluid with free stream velocity is proposed. It is found that the motion equation is controlled by five dimensionless parameters namely the coecostic parameter 4, viscoelostic parameter ?,acceleration/deceleration c,suction/blowing d and material constants ? . The effect of each of these parameters upon the velocity distribution is analysised

View Publication Preview PDF
Crossref
Publication Date
Sat Jan 01 2011
Journal Name
Journal Of Engineering
THE EFFECTS OF BLOOD REHEOLOGICAL ON THE FLOW THROUGH AN AXISYMMETRIC ARTERIAL STENOSIS
...Show More Authors

The prediction of the blood flow through an axisymmetric arterial stenosis is one of the most important aspects to be considered during the Atherosclrosis. Since the blood is specified as a non-Newtonian flow, therefore the effect of fluid types and effect of rheological properties of non-Newtonian fluid on the degree of stenosis have been studied. The motion equations are written in vorticity-stream function formulation and solved numerically. A comparison is made between a Newtonian and non-Newtonian fluid for blood flow at different velocities, viscosity and Reynolds number were solved also. It is found that the properties of blood must be at a certain range to preventing atheroscirasis

View Publication Preview PDF
Crossref
Publication Date
Thu Oct 01 2020
Journal Name
Alexandria Engineering Journal
The operational matrix of Legendre polynomials for solving nonlinear thin film flow problems
...Show More Authors

Scopus (12)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Fri Sep 25 2020
Journal Name
International Journal Of Drug Delivery Technology
Simultaneous Determination of Trace Mefenamic Acid in Pharmaceutical Samples via Flow Injection Fluorometry
...Show More Authors

Mefenamic acid belongs to non-steroidal anti-inflammatory drugs that are used widely for the treatment of analgesia. Our aim from this study is to establish a new assay for the quantitative determination of mefenamic acid (MFA) in the pharmaceutical sample by two sensitive and rapid flow injection-fluorometric methods. A homemade fluorometer was used in fluorescence measurements, which using solid-state laser diode 405 and 532 nm as a source, combined with a continuous flow injection technique. The first method depends on the effect of MFA on calcein blue (CLB) fluorescence at 405 nm. Another method is a study of rhodamine-6G (Rh-6G) fluorescence after adding MFA, and recording at 532 nm. Optimum parameters as fluorescent dye concen

... Show More
View Publication
Scopus (5)
Crossref (4)
Scopus Crossref