Preferred Language
Articles
/
joe-617
Experimental Investigation of Short Square Normal and Hybrid Fiber Reactive Powder Concrete Columns Subjected to Chloride Solution Attack
...Show More Authors

In this research, the structural behavior of reinforced concrete columns made of normal and hybrid reactive powder concrete (hybrid by steel and polypropylene fibers) subjected to chloride salts with concentration was 8341.6 mg/l. The study consists of two parts, the first one is experimental study and the second one is theoretical analysis.  Three main variables were adopted in the experimental program; concrete type, curing type and loading arrangement. Twenty (120x120x1200) mm columns were cast and tested depending on these variables. The samples were reinforced using two different bars; Ø8 for ties and Ø12 with minimum longitudinal reinforcement (0.01Ag). The specimens were divided into two main groups based on curing type: The first group consists of casting and testing of ten columns that cured in tap water for 28 days with two types of concrete (normal and hybrid), five columns for each type. While the second group consists of ten columns that direct cured and fully immersed in chloride water (8341.6 mg/l) 6 months with two types of concrete (normal and hybrid), five columns for each type. The specimens were tested under three types of loading, the first one is axial load, the second one is eccentric load with three different eccentricities (50,100 and 150) mm and where (e/h) are (0.42, 0.83 and 1.25) respectively from the center of column while the third type of loading is tested the specimens as beam.

The experimental results showed an increase in ultimate load capacity and higher chlorides resisting for hybrid reactive powder concrete in comparison with normal concrete in both types of curing (tap and chloride water) through studying strain profile. Interaction diagram charts were obtained from different types of loading for each specimen. These charts showed high values for hybrid reactive powder concrete in comparison with normal concrete.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
EFFCT OF HOOPS AND COLUMN AXIAL LOAD ON SHEAR STRENGTH OF HIGH-STRENGTH FIBER REINFORCED BEAM-COLUMN JOINTS
...Show More Authors

A reinforced concrete frame is referred as "RIGID FRAMES". However, researches indicate that the Beam-Column joint (BCJ) is definitely not rigid. In addition, extensive research shows that failure may occur at the joint instead of in the beam or the column. Joint failure is known to be a catastrophic type which is difficult to repair.
This study was carried out to investigate the effect of hoops and column axial load on the shear strength of high-strength fiber reinforced Beam-Column Joints by using a numerical model based on finite element method using computer program ANSYS (Version 11.0). The variables are: diameter of hoops and magnitude of column axial load.
The theoretical results obtained from ANSYS program are in a good a

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Apr 18 2019
Journal Name
Al-kindy College Medical Journal
Congenital Club Foot Treated By Of Ponseti Method : A Short-Term Results
...Show More Authors

Background: Congenital club foot is a complex deformity of foot .It is a collection of different abnormalities, with different etiologies. Consequently, Severity varies with   difficulties in evaluating treatment strategies with outcome results. The treatment of congenital club foot remains controversial. Usually, the orthopedist's goal is to obtain anatomically and functionally normal feet in all patients.                                Objective: To asses short term follow up result of conservatively treated club feet in relation to the age

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Apr 18 2019
Journal Name
Al-kindy College Medical Journal
Congenital Club Foot Treated By Of Ponseti Method : A Short-Term Results
...Show More Authors

Background: Congenital club foot is a complex deformity of foot .It is a collection of different abnormalities, with different etiologies. Consequently, Severity varies with   difficulties in evaluating treatment strategies with outcome results. The treatment of congenital club foot remains controversial. Usually, the orthopedist's goal is to obtain anatomically and functionally normal feet in all patients.                                Objective: To asses short term follow up result of conservatively treated club feet in relation to the age of initial casting by Ponseti technique.           Methods :A cross sectional observational study with some comparative content done in Al-kindy

... Show More
Preview PDF
Crossref
Publication Date
Sun Sep 25 2022
Journal Name
Hiv Nursing
BIOSYNTHESIS OF SILVER / SILVER CHLORIDE NANOPARTICLES BY IRAQI PROPOLIS AND STUDY THE ANTI – BACTERIAL ACTIVITY
...Show More Authors

Sliver / Sliver chloride is as old used from human but the sliver / sliver chloride nanoparticles have only recently been recogenized. They have used in medicin and agiculture. In the present study have been investigation the effecte biosynthesis Sliver / Sliver chloride nanoparticles as antibacterial by demonstrated that Ag / AgCl NPs arrest the growth of many bacterial: S.typhimurium, k. pneumonia. S. aureus, L.monocytogenes, B. Anthracis, E. coli, C. frundi, S. Pneumonia, P. Aeruginosa. The elements compestion and crystallization panal of biosynthesized nanoparticles were chracterazated by FTIR, XRD and SEM. From XRD, It is confirmed the synthesized nanoparticles contain Sliver / Sliver chloride elements. Synthesized Ag / AgCl NPs showed

... Show More
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Fusion Splicing for a Large Mode Area Photonic Crystal Fiber with Conventional Single Mode Fiber
...Show More Authors

In this paper the experimentally obtained conditions for the fusion splicing with photonic crystal fibers (PCF) having large mode areas were reported. The physical mechanism of the splice loss and the microhole collapse property of photonic crystal fiber (PCF) were studied. By controlling the arc-power and the arc-time of a conventional electric arc fusion splicer (FSM-60S), the minimum loss of splicing for fusion two conventional single mode fibers (SMF-28) was (0.00dB), which has similar mode field diameter. For splicing PCF (LMA-10) with a conventional single mode fiber (SMF-28), the loss was increased due to the mode field mismatch.

View Publication Preview PDF
Publication Date
Mon May 27 2019
Journal Name
Al-khwarizmi Engineering Journal
Investigation the Optimization of Machining Parameters to Surface Roughness in Free Form Surface of Composite Material
...Show More Authors

The aim of this research is to investigation the optimization of the machining parameters (spindle speed, feed rate, depth of cut, diameter of cutter and number of flutes of cutter) of surface roughness for free-form surface of composite material (Aluminum 6061 reinforced boron carbide) by using HSS uncoated flat end mill cutters which are rare use of the free-form surface. Side milling (profile) is the method used in this study by CNC vertical milling machine. The purpose of using ANFIS to obtain the better prediction of surface roughness values and decreased of the error prediction value and get optimum machining parameters by using Taguchi method for the best surface roughness at spindle speed 4500 r.p.m, 920mm/rev feed rate, 0.6mm de

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Nov 24 2025
Journal Name
Scientific Reports
Bearing capacity improvement of medium clay soil using sodium silicate sand columns
...Show More Authors

View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Sat Mar 01 2008
Journal Name
Iraqi Journal Of Physics
Mathematical Model of Amplified Stimulated Raman Scattering and Fiber Raman Amplifier
...Show More Authors

The result of a developed mathematical model for predicting the design
parameters of the fiber Raman amplifier (FRA) are demonstrated. The amplification
parameters are tested at different pump power with different fiber length. Recently,
the FRA employed in optical communication system to increase the repeater distance
as will as the capacity of the communication systems. The output results show, that
high Raman gain can be achieved by high pumping power, long effective area that
need to be small for high Raman gain. High-stimulated Raman gain coefficient is
recommended for high Raman amplifier gain, the low attenuation of the pump and the
transmitted signal in the fiber lead to high Raman gain.

View Publication Preview PDF
Publication Date
Wed Jun 29 2022
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Studying and Analyzing Operating Conditions of Hollow Fiber Membrane Preparation Process
...Show More Authors

Polymeric hollow fiber membrane is produced by a physical process called wet or dry/wet phase inversion; a technique includes many steps and depends on different factors (starting from selecting materials, end with post-treatment of hollow fiber membrane locally manufactured). This review highlights the most significant factors that affect and control the characterization and structure of ultrafiltration hollow fiber membranes used in different applications.        Three different types of polymers (polysulfone PSF, polyethersulfone PES or polyvinyl chloride PVC) were considered to study morphology change and structure of hollow fiber membranes in this review. These hollow fiber membranes were manufactured with different proce

... Show More
View Publication
Crossref
Publication Date
Sun Jan 13 2019
Journal Name
Iraqi Journal Of Physics
The effect of short range correlation on the inelastic C2 and C4 form factors of 18O nucleus
...Show More Authors

The effect of short range correlations on the inelastic Coulomb form factors for excited +2 states (1.982, 3.919, 5.250 and 8.210MeV) and +4 states (3.553, 7.114, 8.960 and 10.310 MeV) in O18 is analyzed. This effect (which depends on the correlation parameterβ) is inserted into the ground state charge density distribution through the Jastrow type correlation function. The single particle harmonic oscillator wave function is used with an oscillator size parameter .b The parameters β and b are adjusted for each excited state separately so as to reproduce the experimental root mean square charge radius of .18O The nucleusO18 is considered as an inert core of C12 with two protons and four neutrons distributed over 212521211sdp−− activ

... Show More
View Publication Preview PDF
Crossref