The planning, designing, construction of excavations and foundations in soft to very soft clay soils are always difficult. They are problematic soil that caused trouble for the structures built on them because of the low shear strength, high water content, and high compressibility. This work investigates the geotechnical behavior of soft clay by using tyre ash material burnt in air. The investigation contains the following tests: physical tests, chemical tests, consolidation test, Compaction tests, shear test, California Bearing Ratio test CBR, and model tests. These tests were done on soil samples prepared from soft clay soil; tyre ash was used in four percentages (2, 4, 6, and 8%). The results of the tests were; The soil samples which gave the value of plasticity test were 2% (25), 4% (25.18), 6% (25.3), and 8% (26.7).The soil samples which gave the value of specific gravity were 2% (2.65), 4% (2.61), 6% (2.5), and 8% (2.36).The value of maximum dry density in a compaction test observed with 2% percentage gave the value 15.8 kN/m3, the 4% gave the value 15.4 kN/m 3 34 , 6% gave 15.3 kN/m 3 and 8%with 15.2 kN/m3 .Samples that gave the values of undrained shear strength test were 2% (55 kN/m 2 ), 4% (76 kN/m2 ), 6% (109 kN/m 2), and 8% (122 kN/m 2). The best of them is 8%. The sample that gave the best value for swelling test was 8%.The best value for compression index Cc was in 8%.The results of CBR test, were improved in all soil samples. The soil samples which gave the value for CBR were 2% (3.507%), 4% (4.308%), 6% (5.586%), and 8% (9.569%). The best value was obtained from 8%.
Background: Because of its clinical and surgical importance and lack of precise information about this rare and important anatomical landmark, this study was designed to detect the presence, configurations and length of Mandibular Retromolar Canal (MRMC) with aid of CBCT visualization. Materials and methods: In this retrospective study the data was obtained from Specialist Health Center in AL-Sadder city in Baghdad for (100) patients with 200 inferior dental canal, all of them referred to CBCT scan (Kodak 9500, French origin). The scanning was done with tube voltage 90 kVp, tube current with 10mA and exposure time was 10 s., the field of view was measured with 5cm x 3.7cmwith 0.03mm voxel size Results: In the present study the prevalence of
... Show MoreAn ultrasonic treatment was applied to the vacuum gas oil at intervals of 5 to 30 minutes, at 70°C. In this work, the improvement of the important properties of Iraqi vacuum gas oil, such as carbon residue, was studied with several parameter conditions that affect vacuum efficiency, such as sonication time (5, 10, 15, 20, 25, and 30) min, power amplitude (10–50%). After ultrasonic treatment, the carbon residue of vacuum gas oil was evaluated using a Conradson carbon residue meter (ASTM D189). The experiment revealed that the oil's carbon residue had decreased by 16%. As a consequence of the experiment It was discovered that ultrasonic treatment might reduce the carbon residual and density of oil samples being studied. It also notice
... Show MoreBackground: The aims of the study were to evaluate the unclean/clean root canal surface areas with a histopathological cross section view of the root canal and the isthmus and to evaluate the efficiency of instrumentation to the isthmus using different rotary instrumentation techniques. Materials and Methods:The mesial roots of thirty human mandibular molars were divided into six groups, each group was composed of five roots (10 root canals)which prepared and irrigated as: Group one A: Protaper system to size F2 and hypodermic syringe, Group one B: Protaper system to size F2 and endoactivator system, Group two A:Wave One small then primary file and hypodermic syringe, Group two B:Wave One small then primary file and endoactivator system, Gr
... Show MoreReduction of noise and vibration in spur gear experimentally by using asymmetric teeth profiles with tip relief was presented. Both of classical (symmetric) and asymmetric (with and without tip relief) spur gears are used in this work. Gear test rig was constructed to achieve torsional vibration measuring, and two modified cutters are designed and manufactured to achieve tooth profile modifications. First to cut asymmetric gear tooth with pressure angles (14.5o/25 o) without tip relief for loaded and unloaded tooth sides respectively, and second to cut asymmetric gear tooth with pressure angles (14.5o/25 o) for loaded and unloaded tooth sides respectively with tip relief to ach
... Show MoreThe basic objective of the research is to study the quality of the water flow service in the Directorate of Karbala sewage and how to improve it after identifying the deviations of the processes and the final product and then providing the possible solutions in addressing the causes of the deviations and the associated quality gaps. A number of quality tools were used and applied to all data Stations with areas and activities related to the drainage of rainwater, as the research community determines the stations of lifting rainwater in the Directorate of the streams of Karbala holy, and the station was chosen Western station to apply the non-random sampling method intended after meeting a number of. It is one of the largest and m
... Show MoreIn current study a computation fluid dynamic (CFD) technique was used to investigate the effect of groynes shape and spacing on the scour pattern and the maximum scour depth in open channel flow. CFD model have been validated throughout comparing the numerical results with three previous experimental studies for a single groyne located in open channel with three different shapes (L, quadrant, and parabola shapes). The comparison revealed very good agreement between numerical results of the maximum scour depth with the results of all experimental models. Moreover, investigations of the effect of multi-groynes (three groynes and four groynes) arranged in parallel with constant spacing and also with variable spacing have been done, the
... Show MoreIn light of the rapid changes in the business environment and the entry of administrative leaders in the challenges of the atheist and twenty- increasing competition between sectors and the desire to acquire the skills, the traditional methods are no longer viable, which requires doing evaluates performance according to a more holistic, rather than limiting the performance evaluation on the financial hub that has not longer enough alone, as well as benchmarking method that has proven successful in developed countries as a way to develop and improve products and services.
I've touched your search to the development of indicators evaluating the performance and preparation of a mechanism for making comparisons of reference between o
... Show MoreThe neutron, proton, and matter densities of the ground state of the proton-rich 23Al and 27P exotic nuclei were analyzed using the binary cluster model (BCM). Two density parameterizations were used in BCM calculations namely; Gaussian (GS) and harmonic oscillator (HO) parameterizations. According to the calculated results, it found that the BCM gives a good description of the nuclear structure for above proton-rich exotic nuclei. The elastic form factors of the unstable 23Al and 27P exotic nuclei and those of their stable isotopes 27Al and 31P are studied by the plane-wave Born approximation. The main difference between the elastic form factors of unstable nuclei and the
... Show MoreQuantum dots (QDs) can be defined as nanoparticles (NPs) in which the movement of charge carriers is restricted in all directions. CdTe QDs are one of the most important semiconducting crystals among other various types where it has a direct energy gap of about 1.53 eV. The aim of this study is to exaine the optical and structural properties of the 3MPA capped CdTe QDs. The preparation method was based on the work of Ncapayi et al. for preparing 3MPA CdTe QDs, and hen, the same way was treated as by Ahmed et al. via hydrothermal method by using an autoclave at the same temperature but at a different reaction time. The direct optical energy gap of CdTe QDs is between 2.29 eV and 2.50 eV. The FTIR results confirmed the covalent bonding betwee
... Show More