The piled raft is a geotechnical composite construction consisting of three elements: piles, raft and soil.
In the design of piled rafts, the load shared between the piles and the raft, and the piles are used up to a
load level that can be of the same order of magnitude as the bearing capacity of a comparable single
pile or even greater. Therefore, the piled raft foundation allows reduction of settlements in a very
economic way as compared to traditional foundation concepts.
This paper presents experimental study to investigate the behavior of piled raft system in sandy
soil. A small scale “prototype” model was tested in a sand box with load applied to the system through
a compression machine. The settlement was measured at the center of the raft, strain gages were used
to measure the strains and calculate the total load carried by piles. Four configurations of piles (2x1,
3x1, 2x2 and 3x2) were tested in the laboratory, in addition to rafts with different sizes. The effects of
pile length, pile diameter, and raft thickness on the load carrying capacity of the piled raft system are
included in the load-settlement presentation.
It was found that the percentage of the load carried by piles to the total applied load of the
groups (2x1, 3x1, 2x2, 3x2) with raft thickness of 5 mm, pile diameter of 9 mm, and pile length of 200
mm was 28% , 38% , 56% , 79% , respectively. The percent of the load carried by piles increases with
the increase of number of piles.
In this study, simply supported reinforced concrete (RC) beams were analyzed using the Extended Finite Element Method (XFEM). This is a powerful method that is used for the treatment of discontinuities resulting from the fracture process and crack propagation in concrete. The mesoscale is used in modeling concrete as a two-phasic material of coarse aggregate and cement mortar. Air voids in the cement paste will also be modeled. The coarse aggregate used in the casting of these beams is a rounded aggregate consisting of different maximum sizes. The maximum size is 25 mm in the first model, and in the second model, the maximum size is 20 mm. The compressive strength used in these beams is equal to 26 MPa.
The subje
... Show MorePurpose: To determine the impact of service encounter in stimulating voluntary customer behaviors.
- Approach / methodology: It was selected a sample of customers Bank Iraqi Trade (TBI) was (105) individual, using a questionnaire designed in the light of previous studies, was drafted scale and tested in the light of a group of statistical methods developed (reliability coefficient, reliability coefficient composite, convergence). Then test hypotheses through structural equation modeling.
- Results: The behaviors and characteristics of the service provider in effect urged bank customers to perform voluntary extra, as the service environment service encounter
The research aims to know the concept of politic behavior as one of the important behaviours in the different fields and sectors. It is considered to be part of the organizatial work to face the expected risks. It includes two group of factors personal (self –monitors, locus of control ,expectation s of success, perceived job alternatives)and organizational(promotion ,division resources,role ambiguity ,democratic decision)studied by the researcher in the frame of the relationship with the variable of display continuous trust matain which includes two variable (build trust mantain, display trust continuouness)through applied frame by random sample consists of (90)employee at Farouq State
... Show MoreExperimental investigations had been done in this study to demonstrate the effect of natural particles used as a reinforcement material to unsaturated polyester resin. The tensile test and water absorption were investigated according to (ASTM D638) and (ASTM D570), respectively. The influence of sunflower husk and pomegranate husk particles, used as a reinforcement material, on the tensile strength, Young's modulus and water absorption with different weight fraction (3%, 7% and 10%) and particle grain size (50µm, 100 µm and 150 µm), has been investigated. The water absorption of polymer composites was studied by measuring the specimen weight before and after immersion in water for one hundred days. In the experiments of tensile test,
... Show MoreIn real conditions of structures, foundations like retaining walls, industrial machines and platforms in offshore areas are commonly subjected to eccentrically inclined loads. This type of loading significantly affects the overall stability of shallow foundations due to exposing the foundation into two components of loads (horizontal and vertical) and consequently reduces the bearing capacity.
Based on a numerical analysis performed using finite element software (Plaxis 3D Foundation), the behavior of model strip foundation rested on dry sand under the effect of eccentric inclined loads with different embedment ratios (D/B) ranging from (0-1) has been explored. The results display that, the bearing capacity of st
... Show MoreChukar partridge Alectoris chukar (Gray, 1830) is the only species of the 46 species of the genus Alectoris to be found in Iraq. At least there are fourteen subspecies of chukar were described from east Europe, the Middle East and west Asia, two of them were known to be found in Iraq, A.c. Kurdestanica (Meinertzhagen, 1923) from Alpine bio-geographical zone of altitude more than 2000m high, and A.c. werae Zarundny and Loudon, 1904, from the foothills of altitude not more than 400m. In between these two regions, there is another bio-geographical region known as the Irano-toranian zone 400-2000m high. Using morphological, ecological, behavioural, reproduction and hybridization criteria this study discove
... Show MoreThere have been many advances in the solar chimney power plant since 1930 and the first pilot work was built in Spain (Manzanares) that produced 50 KW. The solar chimney power plant is considered of a clean power generation that needs to be investigated to enhance the performance by studying the effect of changing the area of passage of air to enhance the velocity towards the chimney to maximize design velocity. In this experimental and numerical study, the reduction area of solar collector was investigated. The reduction area that mean changing the height of glass cover from the absorbing plate (h1=3.8cm, h2=2.6cm and h3=1.28cm). The numerical study was performed using ANSYS Fluent software package (version 14.0) to solve go
... Show MoreThermal performance of closed wet cooling tower has been investigated experimentally and theoretically
in this work. The theoretical model based on heat and mass transfer equations and heat and mass transfer balance equations which are established for steady state case. A new small indirect cooling tower was used for conducting experiments. The cooling capacity of cooling tower is 1 kW for an inlet water temperature of 38oC, a water mass velocity 2.3 kg/m2.s and an air wet bulb temperature of 26oC. This study investigates the relationship between saturation efficiency, cooling capacity and coefficient of performance of closed wet cooling tower versus different operating parameters such wet-bulb temperature, variable air-spray water fl