Preferred Language
Articles
/
joe-276
Thermal Characteristics of Closed Wet Cooling Tower Using Different Heat Exchanger Tubes Arrangement
...Show More Authors

This paper presents thermal characteristics analysis of a modified Closed Wet Cooling Tower (CWCT) based on heat and mass transfer principles to improve the performance of this tower in Iraq. A prototype of CWCT optimized by added packing was designed, manufactured and tested for cooling capacity of 9 kW. Experiments are conducted to explore the effects of various operational and conformational parameters on the thermal performance. In the test section, spray water temperature and both dry bulb temperature and relative humidity of the air measured at intermediate points of the heat exchanger and packing. Heat exchangers consist of four rows and eight columns for an inline tubes arrangement and six rows and five columns for staggered tubes arrangement. According to experimental data, the inline tubes arrangement has a better thermal performance than the staggered tubes arrangement. The inline tubes arrangement enhanced thermal efficiency more than (7%) compared to the staggered tubes arrangement. Furthermore the effect of added packing to CWCT on thermal performance was significant compared to CWCT without packing. Comparing CWCT with packing, it has been observed that the best performance for the CWCT with packing under heat exchanger. It can be watched that the thermal efficiency for CWCT with packing under heat exchanger and CWCT with packing above heat exchanger approximately (28%) and (16%) higher than that CWCT without packing respectively. This study provides correlations to predict heat and mass transfer considering the influences of operational parameters for both inline and staggered heat exchanger tubes arrangement.

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Dec 31 2015
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Reducing of Corrosion Rate in Boiler Tubes by Using Oxygen Scavengers
...Show More Authors

The corrosion behavior of carbon steel at different temperatures 100,120,140 and 160 Cͦ under different pressures 7,10 and 13 bar in pure distilled water and after adding three types of oxygen scavengers Hydroquinone, Ascorbic acid and Monoethanolamine in different concentrations 40,60 and 80 ppm has been investigated using weight loss method. The carbon steel specimens were immersed in water containing 8.2 ppm dissolved oxygen (DO) by using autoclave. It was found that corrosion behavior of carbon steel was greatly influenced by temperature with high pressure. The corrosion rate decreases, when adding any one of oxygen scavengers. The best results were obtained at a concentration of 80 ppm of each scavenger. It was observed that 

... Show More
View Publication Preview PDF
Publication Date
Fri Nov 13 2020
Journal Name
Mechanics Of Advanced Materials And Structures
Enhancing the strength of reinforced concrete columns using steel embedded tubes
...Show More Authors

This paper demonstrates an experimental and numerical study on the behavior of reinforced concrete (RC) columns with longitudinal steel embedded tubes positioned at the center of the column cross-section. A total of 12 pin-ended square sectional columns of 150 × 150 mm having a total height of 1400 mm were investigated. The considered variables were the steel tube diameters of 29, 58, and 76 mm and the load eccentricity (0, 50, and 150) mm. Accordingly, these columns were divided into three groups (four columns in each group) depending on the load eccentricity (e) to column depth (h) ratio (e/h = 0, 1/3, and 1). For each group, one column was solid (reference), and the other three columns contained steel tubes with hollow rat

... Show More
Crossref (17)
Crossref
Publication Date
Fri May 01 2020
Journal Name
Journal Of Engineering
Chemical and Thermal Investigation on Stability of Tanuma Formation Using Different Additives with Drilling Fluids
...Show More Authors

Wellbore stability is considered as one of the most challenges during drilling wells due to the
reactivity of shale with drilling fluids. During drilling wells in North Rumaila, Tanuma shale is
represented as one of the most abnormal formations. Sloughing, caving, and cementing problems
as a result of the drilling fluid interaction with the formation are considered as the most important
problem during drilling wells. In this study, an attempt to solve this problem was done, by
improving the shale stability by adding additives to the drilling fluid. Water-based mud (WBM)
and polymer mud were used with different additives. Three concentrations 0.5, 1, 5 and 10 wt. %
for five types of additives (CaCl2, NaCl, Na2S

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Apr 01 2023
Journal Name
Alexandria Engineering Journal
Employing Sisko non-Newtonian model to investigate the thermal behavior of blood flow in a stenosis artery: Effects of heat flux, different severities of stenosis, and different radii of the artery
...Show More Authors

View Publication
Scopus (28)
Crossref (30)
Scopus Clarivate Crossref
Publication Date
Sat Sep 01 2018
Journal Name
International Journal Of Heat And Mass Transfer
Accelerated melting of PCM in energy storage systems via novel configuration of fins in the triplex-tube heat exchanger
...Show More Authors

View Publication
Scopus (270)
Crossref (265)
Scopus Clarivate Crossref
Publication Date
Tue Sep 01 2015
Journal Name
Journal Of Al-nahrain University-science
St-closed Submodule
...Show More Authors

Abstract Throughout this paper R represents commutative ring with identity and M is a unitary left R-module, the purpose of this paper is to study a new concept, (up to our knowledge), named St-closed submodules. It is stronger than the concept of closed submodules, where a submodule N of an R-module M is called St-closed (briefly N ≤Stc M) in M, if it has no proper semi-essential extensions in M, i.e if there exists a submodule K of M such that N is a semi-essential submodule of K then N = K. An ideal I of R is called St-closed if I is an St-closed R-submodule. Various properties of St-closed submodules are considered.

View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Wed Jan 01 2014
Journal Name
Advances In Mechanical Engineering
Experimental and Numerical Investigations of Heat Transfer Characteristics for Impinging Swirl Flow
...Show More Authors

This paper reports experimental and computational fluid dynamics (CFD) modelling studies to investigate the effect of the swirl intensity on the heat transfer characteristics of conventional and swirl impingement air jets at a constant nozzle-to-plate distance ( L = 2 D). The experiments were performed using classical twisted tape inserts in a nozzle jet with three twist ratios ( y = 2.93, 3.91, and 4.89) and Reynolds numbers that varied from 4000 to 16000. The results indicate that the radial uniformity of Nusselt number (Nu) of swirl impingement air jets (SIJ) depended on the values of the swirl intensity and the air Reynolds number. The results also revealed that the SIJ that was fitted with an insert of y = 4.89, which correspo

... Show More
View Publication
Scopus (16)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Energy Conversion And Management
Simultaneous energy storage and recovery in the triplex-tube heat exchanger with PCM, copper fins and Al2O3 nanoparticles
...Show More Authors

View Publication
Scopus (261)
Crossref (254)
Scopus Clarivate Crossref
Publication Date
Tue Mar 31 2015
Journal Name
Al-khwarizmi Engineering Journal
Experimental Study of the Thermal Diffusivity and Heat Capacity Concerning Some Duplex Stainless Steel
...Show More Authors

Abstract

In the present work, thermal diffusivity and heat capacity measurements have been investigated in temperature range between RT and 1473 K for different duplex stainless steel supplied by Outokumpu Stainless AB, Sweden. The purpose of this study is to get a reliable thermophysical data of these alloys and to study the effect of microstructure on the thermal diffusivity and heat capacity value. Results show the ferrite content in the duplex stainless steel increased with temperature at equilibrium state. On the other hand, ferrite content increased with increasing Cr/Ni ratio and there is no significant effect of ferrite content on the thermal diffusivity value at room temperature. Furthermore, the heat capacity of all sam

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 01 2020
Journal Name
International Journal Of Mathematical Modelling And Numerical Optimisation
Reconstruction of an orthotropic thermal conductivity from non-local heat flux measurements
...Show More Authors

View Publication
Scopus (9)
Crossref (1)
Scopus Crossref