Performance Evaluation of Two Stages Parallel Flow Indirect Evaporative Cooling with Aspen Pads in Baghdad Climate Conditions
...Show More Authors

This study delves into the realm of advanced cooling techniques by examining the performance of a two-stage parallel flow indirect evaporative cooling system enhanced with aspen pads in the challenging climate of Baghdad. The objective was to achieve average air dry bulb temperatures (43 oC) below the ambient wet bulb temperatures (24.95 oC) with an average relative humidity of 23%, aiming for unparalleled cooling efficiency. The research experiment was carried out in the urban environment of Baghdad, characterized by high temperature conditions. The investigation focused on the potential of the two-stage parallel flow setup, combined with the cooling capability of aspen pads, to surpass the limitations imposed by conventional cooling methods. The empirical findings underscored the capacity of the two-stage parallel flow configuration to achieve air-dry bulb temperatures surpassing the ambient wet bulb temperature.

Nonetheless, it was evident that an excessive application of water (exceeding 9 lpm) onto the aspen pads within the wet channels yielded adverse repercussions on the cooler's performance metrics, specifically in terms of wet bulb effectiveness and coefficient of performance. A range of air flows spanning from 150 CMH to 350 CMH was analyzed, revealing the influence of heightened air flow rates on the resultant dry bulb temperatures delivered by the cooling system. Notably, the peak wet-bulb effectiveness registered at 1.08, concurrently yielding a coefficient of performance measuring 7.8.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri May 12 2023
Journal Name
European Journal Of Dentistry
Salivary IL-17 and IL-10 as Potential Diagnostic Biomarkers of Different Stages of Periodontitis in Smoker and Nonsmoker Patients
...Show More Authors
Abstract<p> Objectives The gold standard in the field of periodontal research currently is to find a valid biomarker that can reliably be used for diagnosing periodontal diseases. Given the limitations of the current diagnostic tools that stall to predict susceptible individuals and determine whether active tissue destruction is occurring, there is an increased urge to develop alternative diagnostic techniques that would compensate for the problems inherited in these available methods, such as measuring levels of biomarkers present in oral fluids such as saliva; so the aim of this study was to determine the diagnostic potential of interleukin-17 (IL-17) and IL-10 to differentiate periodontal health </p> ... Show More
View Publication
Scopus (8)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Wed Mar 01 2023
Journal Name
Journal Of Engineering
Effect of a Parked Car Orientation on a Temperature Distribution and Cooling Load Calculation: Experimental Study
...Show More Authors

When a vehicle is left parked in the sun for an extended period, the gathered heat causes damage to several interiors within the cabin and causes discomfort for people and animals left inside the car. In the present work, the effect of the orientation of a parked white minibus on temperature distribution and cooling load calculation is studied experimentally in an open environment. Two different cases were studied facing south and facing east. For several hours, the temperature inside the car cabin had been monitored and measured at five separate locations. The cooling load calculations are carried out based on the experimental measurements. The results show that the overheating of parked cars always happens as a result

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Thu Dec 01 2016
Journal Name
Journal Of Engineering
A Laboratory Study Attempt of Flow and Energy Dissipation in Stepped Spillways
...Show More Authors

A new laboratory study conducted on stepped spillways in order to investigate their efficiency of dissipating flow energy. All previous study on stepped spillway indicated that the flow energy dissipation decreased as increasing in discharge. Increasing in the step numbers and the spillway slope led to energy dissipation decrease. In this study, an experimental attempt to increase energy dissipation at variable discharges was performed on stepped spillway and that leads to decreasing the cost of initiating the stilling basin or may be ignoring it. Five spillways were constructed from concrete and tested to investigate and compare among them. Three were roughed by gravel with different size for each one, one of them was s

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 01 2017
Journal Name
Journal Of Engineering
Effect of Air Bubbles on Heat Transfer Coefficient in Turbulent Convection Flow
...Show More Authors

Experimental and numerical studies have been conducted for the effect of injected air bubbles on the heat transfer coefficient through the water flow in a vertical pipe under the influence of uniform heat flux. The investigated parameters were water flow rate of (10, 14 and 18) lit/min, air flow rate of (1.5, 3 and 4) lit/min for subjected heat fluxes of (27264, 36316 and 45398) W/m2. The energy, momentum and continuity equations were solved numerically to describe the motion of flow. Turbulence models k-ε was implemented. The mathematical model is using a CFD code Fluent (Ansys15). The water was used as continuous phase while the air was represented as dispersed. phase. The experimental work includes design, build and instrument a test

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 01 2020
Journal Name
Baghdad Science Journal
Indirect Spectrofluorometric Method for the Determination of Cefotaxime Sodium, Ciprofloxacin Hydrochloride and Famotidine in Pharmaceuticals Using Bromate-Bromide and Acriflavine Dye
...Show More Authors

An Indirect simple sensitive and applicable spectrofluorometric method has been developed for the determination of Cefotaxime Sodium (CEF), ciprofloxacin Hydrochloride (CIP) and Famotidine (FAM) using reaction system bromate-bromide and acriflavine (AF) as fluorescent dye. The method is based on the oxidation of drugs with known excess bromate-bromide mixture in acidic medium and subsequent determination of unreacted oxidant by quenching fluorescence of AF. Fluorescence intensity of residual AF was measured at 528 nm after excitation at 402 nm. The fluorescence-concentration plots were rectilinear over the ranges 0.1-3.0, 0.05-2.6 and 0.1-3.8 µg ml-1 with lower detection limits of 0.013, 0.018 and 0.021 µg ml-1 an

... Show More
View Publication Preview PDF
Scopus (11)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Sun Jun 30 2013
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Zinc Element Traces to Inhibit Scale Formation on Cooling Tower and Air Cooler Systems
...Show More Authors

Calcium carbonate is predominantly present in aqueous systems, which is
commonly used in industrial processes. It has inverse solubility characteristics
resulting in the deposition of scale on heat transfer surface. This paper focuses on
developing methods for inhibition of calcium carbonate scale formation in cooling
tower and air cooler system where scaling can cause serious problems, ZnCl 2 and ZnI
2 has been investigated as scale inhibitor on AISI 316 and 304. ZnCl 2 were more
effective than ZnI 2 in both systems, and AISI 316 show more receptivity to the
chlorides salt compared to AISI 304. The inhibitors were more effective in cooling
tower than air cooler system. AISI 316 show more constant inhibition effic

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 11 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Evaluation of Nursing staff Performance in Cardiac Care Units at Teaching and Non Teaching Hospitals in Kirkuk City: A Comparative Study
...Show More Authors

Objective: The descriptive study was used to evaluate nursing staff performance in cardiac care units at teaching
and non teaching hospitals in kirkuk city: A comparative study.
Methodology: A descriptive study was used to evaluate nursing staff performance in cardiac care units. The study
was conducted from December 29th
, 2013 up to the 27th of Apr. 2014. A non-probability (purposive) sample of
(44) nurses who work in cardiac care unit at Azady teaching Hospital and Kirkuk general Hospital was evaluated by
a questionnaire which consisted of two parts; the first part is concerned with the demographic characteristics of
the nurses and the second part concerned Observation check list for evaluation nursing staff Perfo

... Show More
View Publication Preview PDF
Publication Date
Fri May 01 2020
Journal Name
International Journal Of Psychosocial Rehabilitation
The Psychological Pollution And Its Role In The Effectiveness Of The Administrative Performance Of International Stadiums Staff (Baghdad, Arbil, Basrah)
...Show More Authors

MT Abed, ALSG Irhayyim, TH Rija, International Journal of Psychosocial Rehabilitation, 2020 - Cited by 1

View Publication
Publication Date
Wed Oct 01 2014
Journal Name
Iosr Journal Of Mathematics
Flow through an Oscillating Rectangular Duct for Generalized Oldroyd-B Fluid with Fractional Derivatives
...Show More Authors

The analytic solution for the unsteady flow of generalized Oldroyd- B fluid on oscillating rectangular duct is studied. In the absence of the frequency of oscillations, we obtain the problem for the flow of generalized Oldroyd- B fluid in a duct of rectangular cross- section moving parallel to its length. The problem is solved by applying the double finite Fourier sine and discrete Laplace transforms. The solutions for the generalized Maxwell fluids and the ordinary Maxwell fluid appear as limiting cases of the solutions obtained here. Finally, the effect of material parameters on the velocity profile spotlighted by means of the graphical illustrations

View Publication
Publication Date
Tue Jun 17 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of tissue displacement in posterior palatal seal area with different impression techniques with varying palatal forms
...Show More Authors

Background: This study was designed to measure the displacement pattern of posterior palatal seal (pps) area in different forms of the palate and with different impression techniques. Materials and method: This study was used to measure the displacement pattern of (pps)in different palatal shapes by using different impression materials Korrecta wax No.4,Green compound and design of House for pps for each palatal forms by using a 3D Scanner of CAD/CAM and measuring the distance between 2 points in pps area by using Caural Threw. Result: The results show highly significant differences between these techniques and the control group (impression with light body) Conclusion: The physiological impression technique of pps with Korecta wax no.4

... Show More
View Publication Preview PDF