Preferred Language
Articles
/
joe-1768
EMG-Based Control of Active Ankle-Foot Prosthesis
...Show More Authors

 Most below-knee prostheses are manufactured in Iraq without considering the fast progress in smart prostheses, which can offer movements in the desired directions according to the type of control system designed for this purpose. The proposed design appears to have the advantages of simplicity, affordability, better load distribution, suitability for subjects with transtibial amputation, and viability in countries with people having low socio-economic status. The designed prosthetics consisted of foot, ball, and socket joints, two stepper motors, a linkage system, and an EMG shield. All these materials were available in the local markets in Iraq. The experimental results showed that the maximum range of motion to move the designed prosthetic in the sagittal and frontal planes reached 70% of the healthy foot range of motion relative to the signals of the gastrocnemius muscle of a healthy leg person. The angles that represented the range of motion achieved in various directions at the ankle joint were Dorsiflexion Angle (35˚), Plantar Flexion Angle (25˚), Inversion Angle (20˚), and Eversion Angle (15˚).

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jan 01 2017
Journal Name
Statistical Applications In Genetics And Molecular Biology
Mixture model-based association analysis with case-control data in genome wide association studies
...Show More Authors
Abstract<p>Multilocus haplotype analysis of candidate variants with genome wide association studies (GWAS) data may provide evidence of association with disease, even when the individual loci themselves do not. Unfortunately, when a large number of candidate variants are investigated, identifying risk haplotypes can be very difficult. To meet the challenge, a number of approaches have been put forward in recent years. However, most of them are not directly linked to the disease-penetrances of haplotypes and thus may not be efficient. To fill this gap, we propose a mixture model-based approach for detecting risk haplotypes. Under the mixture model, haplotypes are clustered directly according to their estimated d</p> ... Show More
View Publication
Scopus (4)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Wed May 01 2024
Journal Name
Journal Of Engineering
Orbital Prosthesis Rehabilitation in Biomedical Engineering by Means of Computer Vision-Photogrammetry and 3D Prototyping
...Show More Authors

Eye loss may be caused as a result of eye trauma, accidents, or malignant tumors, which leads the patient to undergo surgery to remove the damaged parts. This research examines the potential of computer vision represented by Structure from Motion (SfM) photogrammetry in fabricating the orbital prosthesis as a noninvasive and low-cost technique. A low-cost camera was used to collect the data towards extracting the dense 3D data of the patient facial features following Structure from Motion-Multi View Stereo (SfM-MVS) algorithms. To restore the defective orbital, a Reverse Engineering (RE) based approach has been applied using the similarity RE algorithms based on the opposite healthy eye to rehabilitate the defected orbital precisely

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Tue Aug 28 2018
Journal Name
Mechanical Sciences
Mechatronic design and genetic-algorithm-based MIMO fuzzy control of adjustable-stiffness tendon-driven robot finger
...Show More Authors

Abstract. This work presents a detailed design of a three-jointed tendon-driven robot finger with a cam/pulleys transmission and joint Variable Stiffness Actuator (VSA). The finger motion configuration is obtained by deriving the cam/pulleys transmission profile as a mathematical solution that is then implemented to achieve contact force isotropy on the phalanges. A VSA is proposed, in which three VSAs are designed to act as a muscle in joint space to provide firm grasping. As a mechatronic approach, a suitable type and number of force sensors and actuators are designed to sense the touch, actuate the finger, and tune the VSAs. The torque of the VSAs is controlled utilizing a designed Multi Input Multi Output (MIMO) fuzzy controll

... Show More
View Publication
Scopus (7)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Tue Sep 01 2020
Journal Name
Asian Journal Of Pharmacy And Pharmacology
Genetic polymorphisms associated with diabetic foot ulcer: A review article
...Show More Authors

Diabetic foot ulcer (DFU) or Lower limb ulcers are one of the major complications caused by diabetes mellitus especially when patients fail to maintain tight glycemic control. DFU is linked to multiple risk factors along with the genetic factors and ethnicity which play a significant role in the development of DFUs through their effects on multiple aspects of the pathophysiological process. This narrative review aimed to summarize all the previous studies within the last ten years associating gene polymorphism and DFU. Polymorphism associated with vascular endothelial growth factor (rs699947), the G894T polymorphism of the endothelial nitric oxide synthase gene, interleukin-6–174 G>C gene polymorphism, heat shock protein 70 gene polymorph

... Show More
Preview PDF
Crossref (4)
Crossref
Publication Date
Tue Sep 01 2020
Journal Name
Asian Journal Of Pharmacy And Pharmacology
Genetic polymorphisms associated with diabetic foot ulcer: A review article
...Show More Authors

View Publication
Crossref (4)
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Opcion, Año
Active Learning And Creative Thinking
...Show More Authors

Active Learning And Creative Thinking

Publication Date
Sun Jan 01 2023
Journal Name
8th Engineering And 2nd International Conference For College Of Engineering – University Of Baghdad: Coec8-2021 Proceedings
Cascade position-torque control strategy based on function approximation technique (FAT) for flexible joint robots
...Show More Authors

View Publication
Crossref (1)
Crossref
Publication Date
Tue May 23 2023
Journal Name
Journal Of Sensors
On-Board Digital Twin Based on Impedance and Model Predictive Control for Aerial Robot Grasping
...Show More Authors

Aerial manipulation of objects has a number of advantages as it is not limited by the morphology of the terrain. One of the main problems of the aerial payload process is the lack of real-time prediction of the interaction between the gripper of the aerial robot and the payload. This paper introduces a digital twin (DT) approach based on impedance control of the aerial payload transmission process. The impedance control technique is implemented to develop the target impedance based on emerging the mass of the payload and the model of the gripper fingers. Tracking the position of the interactional point between the fingers of gripper and payload, inside the impedance control, is achieved using model predictive control (MPD) approach.

... Show More
View Publication
Scopus (5)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Thu Dec 01 2022
Journal Name
Ieee Transactions On Human-machine Systems
Myoelectric Control With Fixed Convolution-Based Time-Domain Feature Extraction: Exploring the Spatio–Temporal Interaction
...Show More Authors

View Publication
Scopus (31)
Crossref (32)
Scopus Clarivate Crossref
Publication Date
Fri Dec 01 2017
Journal Name
2017 11th Asian Control Conference (ascc)
Super-twisting based integral sliding mode control applied to a rotary flexible joint robot manipulator
...Show More Authors

In this paper, a single link flexible joint robot is used to evaluate a tracking trajectory control and vibration reduction by a super-twisting integral sliding mode (ST-ISMC). Normally, the system with joint flexibility has inevitably some uncertainties and external disturbances. In conventional sliding mode control, the robustness property is not guaranteed during the reaching phase. This disadvantage is addressed by applying ISMC that eliminates a reaching phase to ensure the robustness from the beginning of a process. To design this controller, the linear quadratic regulator (LQR) controller is first designed as the nominal control to decide a desired performance for both tracking and vibration responses. Subsequently, discontinuous con

... Show More
View Publication
Scopus (11)
Crossref (8)
Scopus Crossref