This paper presents an experimental study of cooling photovoltaic (PV) panels using evaporative cooling. Underground (geothermal energy) water used to extract heat from it during cooling and cleaning of PV panels. An experimental test rig was constructed and tested under hot and dusty climate conditions in Baghdad. An active cooling system was used with auxiliary an underground water tank to provide cold water as a coolant over both PV surfaces to reduce its temperature. The cellulose pad has been arranged on the back surface and sprays cooling on the front side. Two identical PV panels modules used: without cooling and evaporative water cooling. The experiments are comprised of four cases: Case (I): backside cooling, Case (II): front and back cooling (pump supply water every 35 minutes), Case (III): cooling both sides using Arduino controller. Water cooling pump operation depending on the panel temperatures (temperature sensors were installed on the front of the panel), Case (IV): Repeating case III with different water flow rates. Experimental results showed that the average reduction in module temperatures was 4, 8,12.2 and 12.6 ⁰C respectively by Case (I), (II), (III) and (IV) with respect to a non-cooling module. Using evaporative water cooling achieved a total improvement of 1.74%, 2.8%, 15.8%, and 16% in the conversion efficiency of the panel by the Case (I), (II), (III) and (IV) respectively when compared to a non-cooling module.
This work introduces a new electrode geometry for making holes with high aspect ratios on AISI 304 using an electrical discharge drilling (EDD) process. In addition to commercially available cylindrical hollow electrodes, an elliptical electrode geometry has been designed, manufactured, and implemented. The principal aim was to improve the removal of debris formed during the erosion process that adversely affects the aspect ratio, dimensional accuracy, and surface integrity. The results were compared and discussed to evaluate the effectiveness of electrode geometry on the machining performance of EDD process with respect to the material removal rate (MRR,) the electrode wear rate (EWR), and the tool wear ratio (TWR). Dimensional features an
... Show MoreFurfural is one of the one of pollutants in refinery industrial wastewaters. In this study advanced oxidation process using UV/H2O2 was investigated for furfural degradation in synthetic wastewater. The results from the experimental work showed that the degradation of furfural decreases as its concentration increases, reaching 100% at 50mg/l furfural concentration and increasing the concentration of H2O2 from 250 to 500 mg/l increased furfural removal from 40 to 60%.The degradation of furfural reached 100% after 90 min exposure time using two UV lamps, where it reached 60% using one lamp after 240 min exposure time. The rate of furfural degradation k increased at the pH and initial concentratio
... Show MoreDrip irrigation is one of the conservative irrigation techniques since it implies supplying water directly on the soil through the emitter; it can supply water and fertilizer directly into the root zone. An equation to estimate the wetted area in unsaturated soil is taking into calculating the water absorption by roots is simulated numerically using HYDRUS (2D/3D) software. In this paper, HYDRUS comprises analytical types of the estimate of different soil hydraulic properties. Used one soil type, sandy loam, with three types of crops; (corn, tomato, and sweet sorghum), different drip discharge, different initial soil moisture content was assumed, and different time durations. The relative error for the different hydrauli
... Show MoreThe primary function of commercial banks is the process of converting liquid liabilities such as deposits to illiquid assets, (also known as a loan), liquid assets, (aka cash and cash equivalent) in a balanced manner between liquid and illiquid assets, that guaranteed the preservation of the rights of depositors and the bank and not by converting liquid liabilities into liquid assets in a very large percentage. This comes from its role as depository and intermediary institutions between supply and demand, therefore, we find that the high indicators of bank liquidity and solvency may reflect a misleading picture of the status of commercial banks, to some extent in terms of the strength of their balance sheets and
... Show MoreIn this research the performance of 5G mobile system is evaluated through the Ergodic capacity metric. Today, in any wireless communication system, many parameters have a significant role on system performance. Three main parameters are of concern here; the source power, number of antennas, and transmitter-receiver distance. User equipment’s (UEs) with equal and non-equal powers are used to evaluate the system performance in addition to using different antenna techniques to demonstrate the differences between SISO, MIMO, and massive MIMO. Using two mobile stations (MS) with different distances from the base station (BS), resulted in showing how using massive MIMO system will improve the performance than the standar
... Show MoreIntroduction: Breast cancer is a significant global health concern, affecting millions of women worldwide. While advancements in diagnosis and treatment have improved survival rates, the impact of this disease extends beyond physical health. It also significantly influences a woman's lifestyle and overall well-being. Objectives: The current study intends to analyze the lifestyle of breast cancer patients who are receiving therapy or are being followed up at the Oncology Teaching Hospital in Medical City, Baghdad, Iraq. Method: The present study uses a descriptive design with an application of an evaluation approach. A convenience sample of 100 women with breast cancer was selected from the Teaching Oncology Hospital at the Medical C
... Show MoreBiosorpion of lead (Pb), Cadmium (Cd) and Nickl(Ni) by dried biomass of Chara sp. for sample of BMP was used as alternative approach of conventional method. The range of removal percentages was between 92-97%, 70-98.7% and 46.6-96.6% for Pb, Cd and Ni respectively at 3h.Treatment time, with 300-500 mg dried weight from Chara sp. powder at pH 4, with 60 rpm at shaker. FTIR analysis showed the active groups which are responsible for sequestration of heavy metals represented by carboxyl, hydroxyl alkyl, amine and amide. The Biosorption equilibrium experiment for elements showed that the highest sorption percentage for three elements was, Pb 96.6% after 30 minute, for Cd was 100% after 15 minute and 40% to Ni after 75 minute, while the biosorp
... Show MoreClean water supply is one of the major factors contributing significantly to society’s socio-economic transformation by improving living standards, health, and increasing productivity. It is imperative to plan and construct appropriate water supply systems in modern society, which supply various segments of society with safe drinking water according to their requirements to ensure adequate and quality water supply. In the current study, here was an attempt to develop a model for geographic information systems to manage the assets of the water distribution networks in the Karrada region and to evaluate the network geometrically, and from the results of the engineering analysis of the
The object of the presented study was to monitor the changes that had happened in the main features (water, vegetation, and soil) of Al-Hammar Marsh region. To fulfill this goal, different satellite images had been used in different times, MSS 1973, TM 1990, ETM+ 2000, 2002, and MODIS 2009, 2010. A new technique of the unsupervised classification called (Color Extracting Technique) was used to classify the satellite images. MATLAP programming used the technique and separated Al-Hammar Marsh from other water features (rivers, irrigated lands, etc.) when calculated the changes in the water content of the study region. ArcGIS 9.3 (arcMAP, arcToolbox) were used to achieve this work and calculate area of each class.