Preferred Language
Articles
/
joe-1142
Preparation and Characterization of Plaster Kiln Dust-Fe3O4 Magnetic Nanoparticles
...Show More Authors

Magnetic plaster kiln dust (MPKD) was synthesized as a unique, low-cost composite reused of byproduct plaster kiln dust (PKD), which is considered a source of air pollution. The FESEM, EDS, XRD, FTIR, VSM, and BET tests were used to characterize the MPKD. The characterization revealed that the MPKD was nanotubes non-agglomerated and super-paramagnetic with a high specific surface area (102.7 m2/g). Compared with the specific area of other materials (composites), the MPKD could be considered a promising substance in the field of water/wastewater treatment.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Sep 10 2018
Journal Name
Iraqi Journal Of Physics
The influence of magnetic field and cathode dimensions on plasma characteristics in hollow cathode system
...Show More Authors

Experimental study on the effect of cylindrical hollow cathode, working pressure and magnetic field on spatial glow distribution and the characteristics of plasma produced by dc discharge in Argon gas, were investigated by image analyses for the plume within the plasma. It was found that the emission intensity appears as a periodic structure with many peaks appeared between the electrodes. Increasing the pressure leads to increase the number of intensity peaks finally converted to continuous form at high pressure, especially with applied of magnetic field, i.e. the plasma is more stable with the presence of magnetic field. The emission intensity study of plasma showed that the intensity has a maximum value at 1.07 mbar pressure and decre

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Mar 26 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Formulation and Evaluation of Ezetimibe Nanoparticles
...Show More Authors

The aim of this study is to formulate and evaluate ezetimibe nanoparticles using solvent antisolvent technology. Ezetimibe is a practically water-insoluble drug which acts as a lipid lowering drug that selectively inhibits the intestinal absorption of cholesterol and related phytosterols. Ezetimibe prepared as nano particles in order to improve its solubility and dissolution rate.

Thirty formulas were prepared and different stabilizing agents were used with different concentrations such as poly vinyl pyrrolidone (PVPK-30), poly vinyl alcohol (PVA), hydroxy propyl methyl cellulose E5 (HPMC), and poloxamer. The ratios of drug to stabilizers used to prepare the nanoparticles were 1: 2, 1:3 and 1:4.

The prepared nanoparticles

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Aug 01 2020
Journal Name
Journal Of Engineering
Statistical Analysis of Metal Removal during Magnetic Abrasive Finishing Process
...Show More Authors

This work aims to provide a statistical analysis of metal removal during the Magnetic Abrasive Finishing process (MAF) and find out the mathematical model which describes the relationship between the process parameters and metal removal, also estimate the impact of the parameters on metal removal. In this study, the single point incremental forming was used to form the truncated cone made of low carbon steel (1008-AISI) based on the Z-level tool path. Then the finishing was accomplished using a magnetic abrasive process based on the Box-Behnken design of the experiment using Minitab 17 software was used to finish the surface of the formed truncated cone. The influences of different parameters (feed rate, machining step s

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Tue Jul 01 2008
Journal Name
Arabian Journal Of Geosciences
Sub-surface geometry of Ar Rika and Ruwah faults from gravity and magnetic surveys
...Show More Authors

View Publication
Scopus (5)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Mon Oct 15 2018
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
STUDY OF THE EFFECT OF MAGNETIC FIELD POLES ON THE GROWTH OF Staphylococcus AND Streptococcus ISOLATED FROM TOOTH DECAY: STUDY OF THE EFFECT OF MAGNETIC FIELD POLES ON THE GROWTH OF Staphylococcus AND Streptococcus ISOLATED FROM TOOTH DECAY
...Show More Authors

The study aimed to determine the impact of energy for the north and south magnetic poles on the the growth of bacteria isolated from cases of tooth decay, 68 swabs were collected from surfaces of faulty tooth, the detected of Staphylococcus aureus

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 03 2018
Journal Name
Journal Of Engineering
Variable Structure Control Design for a Magnetic Levitation System
...Show More Authors

In this paper the variable structure control theory is utilized to derive a discontinuous controller to the magnetic levitation system. The magnetic levitation system model is considered uncertain, which subjected to the uncertainty in system parameters, also it is open-loop unstable and strongly nonlinear. The proposed variable structure control to magnetic levitation system is proved, and the area of attraction is determined. Additionally, the chattering, which induced due to the discontinuity in control law, is attenuated by using a non-smooth approximate. With this approximation the resulted controller is a continuous variable structure controller with a determined steady state error according to the selected control

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Apr 01 2024
Journal Name
Indonesian Journal Of Chemistry
Preparation, Characterization, and Biological Activity of La(III), Nd(III), Er(III), Gd(III), and Dy(III) Complexes with Schiff Base Resulted from Reaction of 4-Antipyrinecarboxaldehyde and 2-Aminobenzothiazole
...Show More Authors

The research includes the preparation of several complexes of the internal transition elements lanthanide (Ln = La, Nd, Er, Gd, and Dy) containing the 4f shell, with Schiff bases resulting from condensation reactions between 4-antipyrinecarboxaldehyde and 2-aminobenzothiazoles. Schiff's base was identified using FTIR spectra, UV-vis spectroscopy, elemental microanalysis CHNSO, nuclear magnetic resonance, mass spectrometry, and TGA thermal analysis. The complexes were studied and identified with elemental microanalysis CHNSO, FTIR spectroscopy, UV-vis spectroscopy, TGA thermal analysis, conductivity measurement, and magnetic sensitivity. The result showed that these complexes were classified as homogeneous bidentate complexes with th

... Show More
View Publication
Scopus (3)
Scopus Clarivate Crossref
Publication Date
Mon Feb 01 2021
Journal Name
Materials Science And Engineering
Effect of magnetic water on strength properties of concrete
...Show More Authors
Abstract<p>The research’s main goal is to investigate the effects of using magnetic water in concrete mixes with regard to various mechanical properties such as compressive, flexural, and splitting tensile strength. The concrete mix investigated was designed to attain a specified cylinder compressive strength (30 MPa), with mix proportions of 1:1.8:2.68 cement to sand to crushed aggregate. The cement content was about 380 kg/m<sup>3</sup>, with a w/c ratio equal to 0.54, sand content of about 685 kg/m3, and gravel content of about 1,020 kg/m3. Magnetic water was prepared via passing ordinary water throughout a magnetic field with a magnetic intensity of 9,000 Gauss. The strength test</p> ... Show More
Crossref (6)
Crossref
Publication Date
Fri Nov 29 2013
Journal Name
Arabian Journal Of Geosciences
Cd, Ni, and Pb distribution and pollution assessment in roadside dust from Baghdad City and Western Iraqi Desert
...Show More Authors

View Publication
Crossref (11)
Crossref
Publication Date
Wed Apr 12 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Ion Beam Focusing in Solenoid Magnetic Field
...Show More Authors

   The present study investigates the main parameters effect on the solenoid design as converging lens of charged particle beam passing through it. These parameters are solenoid magnetic field (B), solenoid radius (Ro) and the solenoid total length (L). The result indicates that the solenoid system is very sensitive to the change of these parameters. The solenoid acts as converge lens but may convert to diverging lens at some conditions. The best design obtained at (L=1100 mm, B=5000 gauss and Ro=150 mm).      
 

View Publication Preview PDF